109050 Euchner Safety Proximity Sensors

109050 on MQ Automation
Euchner
  • 109050
  • 109050
  • 109050

Part#:109050

Alt. Part#:CES-AR-CR2-AH-L10-109050

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

109050 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Product Details

  • Weight
    0.881848 lb
  • Series
    CES-AR
  • Product Class
    Safety System
  • Assured operating distance Sao
    min.10 mm
  • Switching hysteresis
    min.1 mm
  • Assured release distance Sar
    max.40 mm
  • Mission time
    20
  • Operating distance
    15 mm
  • PFHD
    1.9 x 10⁻⁹
  • Category
    4
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Repeat accuracy R
    ≤ 10
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated conditional short-circuit current
    100 A
  • Test-pulse interval
    min.140 ms
  • Output voltage
    0,8 x UB ... UB V DC
  • Test pulses
    max.1 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Turn-on time
    max.400 ms
  • Safety class
    III
  • Switching current
    max.50 mA
  • Type of output
    p-switching, short circuit-proof
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Rated insulation voltage Ui
    75 V
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Fusing
    0,25 ... 8 A
  • Switching frequency
    max.1 Hz
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5 %
  • Current consumption
    max.50 mA (Without taking into account the load currents on the monitoring output and the safety outputs)
  • Mounting distance
    min.120 mm
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Ready delay
    10 s
  • Installation orientation
    Any
  • Connection
    connection cable PUR, length 10m
  • Tightening torque
    max.1 Nm
  • Cable ambient temperature (dynamic)
    -25 ... 65 °C
  • Weight
    0,36 kg
  • Degree of protection
    IP67, IP69K
  • Dynamic bending radius
    10 x cable diameter
  • Mounting method
    Surface mounting on metal
  • Housing material
    Plastic, PBT
  • Static bending radius
    5 x cable diameter
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Cable ambient temperature (static)
    -30 ... 65 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 109050 on MQ Automation is $355.34. Order now.


About the product

Safety switch with integrated evaluation electronics;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Door hinge right;Category 4 / PL e according to EN ISO 13849-1;Connecting cable PUR, 10 m, flying lead, 8-core;Unicode;Two safety screws M4x14 included


Manufacturer warranty

109050 Euchner

$355.34

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$355.34

$355.34 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 109050 with other products

Weight

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Mission time

Operating distance

PFHD

Category

Performance Level

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc....

Rated conditional short-c...

Test-pulse interval

Output voltage

Test pulses

Turn-on time

Safety class

Switching current

Type of output

Degree of contamination (...

EMC protection requiremen...

Rated insulation voltage ...

Risk time according to EN...

Rated impulse withstand v...

Fusing

Switching frequency

Operating voltage DC

Current consumption

Mounting distance

Extension of risk time ac...

Ready delay

Installation orientation

Connection

Tightening torque

Cable ambient temperature...

Degree of protection

Dynamic bending radius

Mounting method

Housing material

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Selected product

109050
0 in stock
109050
Euchner

109050 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Weight0.881848 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.10 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.40 mm

Mission time20

Operating distance15 mm

PFHD1.9 x 10⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Test pulsesmax.1 ms (Applies for a loa...

Turn-on timemax.400 ms

Safety classIII

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui75 V

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.50 mA (Without taking i...

Mounting distancemin.120 mm

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Installation orientationAny

Connectionconnection cable PUR, length...

Tightening torquemax.1 Nm

Cable ambient temperature (dynamic)-25 ... 65 °C

Degree of protectionIP67, IP69K

Dynamic bending radius10 x cable diameter

Mounting methodSurface mounting on metal

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-30 ... 65 °C

109052
68 in stock
109052
Euchner

109052 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Weight1.763696 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.10 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.40 mm

Mission time20

Operating distance15 mm

PFHD1.9 x 10⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Test pulsesmax.1 ms (Applies for a loa...

Turn-on timemax.400 ms

Safety classIII

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui75 V

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.50 mA (Without taking i...

Mounting distancemin.120 mm

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Installation orientationAny

Connectionconnection cable PUR, length...

Tightening torquemax.1 Nm

Cable ambient temperature (dynamic)-25 ... 65 °C

Degree of protectionIP67, IP69K

Dynamic bending radius10 x cable diameter

Mounting methodSurface mounting on metal

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-30 ... 65 °C

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.14 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Mission time20

Operating distance19 mm

PFHD1.9 x 10⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Test pulsesmax.1 ms (Applies for a loa...

Turn-on timemax.400 ms

Safety classIII

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui75 V

Risk time according to EN 60947-5-3max.260 ms

Rated impulse withstand voltage Uimp1,5 kV

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Operating voltage DC24 V DC 15% ... 15% Regu...

Current consumptionmax.50 mA (Without taking i...

Mounting distancemin.120 mm

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Installation orientationAny

ConnectionConnection cable PUR, length...

Tightening torquemax.1 Nm

Cable ambient temperature (dynamic)-25 ... 65 °C

Degree of protectionIP67

Dynamic bending radius10 x cable diameter

Mounting methodSurface mounting on metal

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 109050?
The price of 109050 on MQ Automation is $355.34. Order now.

Out if stock but available for backorder.

109050 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

What can I help you find today?

Recommended parts