109015 Euchner Safety Proximity Sensors

109015 on MQ Automation
Euchner
  • 109015
  • 109015
  • 109015

Part#:109015

Alt. Part#:CET1-AR-CRA-CH-50X-SG-C2290-109015

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

109015 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden)

Product Details

  • Weight
    3.9132005 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    Depending on external control of guard locking (LEDs have the same ground potential as the guard locking solenoid.)
  • Mission time
    20 y
  • Performance Level
    Depending on external control of guard locking (LEDs have the same ground potential as the guard locking solenoid.)
  • Category
    Depending on external control of guard locking (LEDs have the same ground potential as the guard locking solenoid.)
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Repeat accuracy R
    10 %
  • Turn-on time
    400 ms
  • Off-state current Ir
    max.0,25 mA
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Output voltage
    UB-1,5V ... UB V DC (Values at a switching current of 50mA without taking into account the cable lengths)
  • Discrepancy time
    max.10 ms
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Safety class
    III
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Fusing
    0,25 ... 8 A
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Connection rating
    11 W
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Current consumption
    450 mA
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Switching frequency
    max.0,5 Hz
  • Locking force FZh
    5000 N
  • Guard locking principle
    Closed-circuit current principle
  • Approach speed
    max.20 m/min
  • Ready delay
    10 s
  • Locking force Fmax
    6500 N
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Degree of freedom Y
    ±5 mm
  • Degree of freedom X
    ±5 mm
  • Degree of freedom Z
    ±4 mm
  • Housing material
    Stainless steel
  • Installation orientation
    Any (Preferably head downward)
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Weight
    1 kg
  • Ambient temperature
    -20 ... 55 °C
  • Mechanical life
    1 x 10⁶

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 109015 on MQ Automation is $933.41. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Wire front release (bowden), 3 m, automatic return;Approach direction A (delivery state)


Manufacturer warranty

109015 Euchner

$933.41

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$933.41

$933.41 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 109015 with other products

Weight

Series

Product Class

PFHD

Mission time

Performance Level

Category

For the approval acc. to ...

Repeat accuracy R

Turn-on time

Off-state current Ir

Risk time according to EN...

Output voltage

Discrepancy time

Output current

Type of output

Switching load

Extension of risk time ac...

Safety class

Solenoid duty cycle

EMC protection requiremen...

Fusing

Degree of contamination (...

Solenoid operating voltag...

Connection rating

Utilization category acc....

Current consumption

Operating voltage DC

Switching frequency

Locking force FZh

Guard locking principle

Approach speed

Ready delay

Locking force Fmax

Connection

Degree of freedom Y

Degree of freedom X

Degree of freedom Z

Housing material

Installation orientation

Degree of protection

Ambient temperature

Mechanical life

Additional feature

Switching current

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

Shock and vibration resis...

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

109015
0 in stock
109015
Euchner

109015 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden)

Weight3.9132005 lb

SeriesCET-AR

Product ClassSafety System

PFHDDepending on external contro...

Mission time20 y

Performance LevelDepending on external contro...

CategoryDepending on external contro...

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on time400 ms

Off-state current Irmax.0,25 mA

Risk time according to EN 60947-5-3max.400 ms

Output voltageUB-1,5V ... UB V DC (Values...

Discrepancy timemax.10 ms

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-swi...

Switching load24V DC, class 2 (For altern...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Degree of contamination (external, according to EN 60947-1)3

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Connection rating11 W

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Current consumption450 mA

Operating voltage DC24 V DC -15% ... 10%

Switching frequencymax.0,5 Hz

Locking force FZh5000 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Ready delay10 s

Locking force Fmax6500 N

Connection2 plug connectors M12, 5 and...

Degree of freedom Y±5 mm

Degree of freedom X±5 mm

Degree of freedom Z±4 mm

Housing materialStainless steel

Installation orientationAny (Preferably head downwa...

Degree of protectionIP67 (Screwed tight plug co...

Ambient temperature-20 ... 55 °C

Mechanical life1 x 10⁶

Additional feature-

Switching current-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

Shock and vibration resistance-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Risk time according to EN 60947-5-3max.260 ms

Output voltage0,8xUB ... UB V DC

Discrepancy timemax.10 ms In acc. with EN ...

Output current-

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Degree of contamination (external, according to EN 60947-1)3

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Ready delay8 s

Locking force Fmax3900 N

Connection2 plug connectors M12, 5 and...

Degree of freedom Y-

Degree of freedom X-

Degree of freedom Z-

Housing materialDie-cast zinc

Installation orientationAny

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Additional featureEscape release actuated by p...

Switching current1 ... 50 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Risk time according to EN 60947-5-3-

Output voltage0 ... 1 V DC

Discrepancy timemax.10 ms In acc. with EN ...

Output current-

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (Alternativ...

Extension of risk time according to EN 60947-5-3 per device-

Safety classIII

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Degree of contamination (external, according to EN 60947-1)3

Solenoid operating voltage DC-

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Locking force FZh-

Guard locking principle-

Approach speedmax.20 m/min

Ready delaymax.1 s

Locking force Fmax-

Connection2 plug connectors M12, 5-pin

Degree of freedom Y-

Degree of freedom X-

Degree of freedom Z-

Housing materialFiber glass reinforced therm...

Installation orientationDoor hinge DIN right

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Additional feature-

Switching current1 ... 150 mA

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 109015?
The price of 109015 on MQ Automation is $933.41. Order now.

Out if stock but available for backorder.

109015 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden)

What can I help you find today?

Recommended parts