097225 Euchner Safety Relays

097225 on MQ Automation
Euchner
  • 097225
  • 097225
  • 097225

Part#:097225

Alt. Part#:ESM-BA701P

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

Product description

097225 Euchner - Basic device ESM-BA7.., 7 safety contacts, 4 auxiliary contacts, 2 monitoring contacts, cat. 4

Product Details

  • Weight
    0.78925396 lb
  • Series
    ESM
  • Product Class
    safety relay
  • In compliance with
    EN ISO 13849-1:2015; EN 62061:2005+AC:2010+A1:2013+A2:2015; EN 50581: 2012 (RoHS)
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.500000 1/Jahr
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • PFHD
    2.47 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Breaking capacity according to UL
    2 A 250 V AC / 1.5 A 24 V DC per contact
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Fusing
    10AgG
  • Cumulative current
    max.35 A For all contacts (With a housing distance of 10mm. 20A closely spaced at 40°C)
  • Switching voltage
    max.250 V
  • Switching current
    min.5 mA at 24V
  • Type of output
    Short circuit-proof (On +24V DC (internal))
  • Output voltage
    24 V DC
  • Output current
    max.30 mA
  • Utilization category acc. to EN 60947-5-1
    8A, 250V
  • LED indicator
    One operating voltage status display (Pwr), two status displays (green) for relays K1 and K2
  • Control current
    250 mA
  • Control voltage
    24 V 18,6 ... 26 V Start button
  • Test voltage
    2,5 kV
  • Connection cross-section
    0,14 ... 2,5 mm² (Connection terminal (size))
  • Overvoltage category according to IEC EN 60664-1
    3
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Rated impulse withstand voltage Uimp
    4 kV
  • Rated insulation voltage Ui
    250 V
  • Operating voltage
    24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Connection rating
    4,5 W
  • Power consumption (apparent power)
    8,5 VA
  • Number of safety contacts
    7
  • Number of auxiliary contacts
    4
  • Number of monitoring contacts
    2
  • Contact material
    AgSnO2
  • Length of control cable
    1000 m
  • Connection
    Plug-in connection terminals
  • Number of monitoring outputs
    2 semiconductor outputs
  • Weight
    0,35 kg
  • Ambient temperature
    -15 ... 40 °C
  • Housing material
    Polyamide PA6.6
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Mechanical life
    10 x 10⁶
  • Degree of protection
    IP20

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 097225 on MQ Automation is $638.40. Order now.


About the product

ESM-BA.. Use up to category 4 according to EN ISO 13849-1;LED status indicators;1-channel or 2-channel control;7 redundant safety contacts;4 auxiliary contacts;2 monitoring contacts;Short circuit and earth fault/ground fault monitoring optional;plug-in connection terminals


Manufacturer warranty

097225 Euchner

$638.40

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$638.40

$638.40 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 097225 with other products

Weight

Series

Product Class

In compliance with

Mission time

Number of switching cycle...

Category

PFHD

Breaking capacity accordi...

Performance Level

Fusing

Cumulative current

Switching voltage

Switching current

Type of output

Output voltage

Output current

Utilization category acc....

LED indicator

Control current

Control voltage

Test voltage

Connection cross-section

Overvoltage category acco...

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Operating voltage

Connection rating

Power consumption (appare...

Number of safety contacts

Number of auxiliary conta...

Number of monitoring cont...

Contact material

Length of control cable

Connection

Number of monitoring outp...

Ambient temperature

Housing material

Mounting method

Mechanical life

Degree of protection

B10D

For the approval acc. to ...

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Safety class

Turn-on time

Switching load

EMC protection requiremen...

Utilization category acc....

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Installation orientation

Shock and vibration resis...

Approach speed

Switching frequency

Ready delay

Additional feature

Solenoid duty cycle

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Locking force FZh

Retention force

Locking force Fmax

Actuation frequency

Guard locking principle

Number of door position N...

Switching principle

Number of guard lock moni...

Number of guard lock moni...

Selected product

097225
0 in stock
097225
Euchner

097225 Euchner - Basic device ESM-BA7.., 7 safety contacts, 4 auxiliary contacts, 2 monitoring conta...

Weight0.78925396 lb

SeriesESM

Product Classsafety relay

In compliance withEN ISO 13849-1:2015; EN 6206...

Mission time20 y (This value is depend...

Number of switching cyclesmax.500000 1/Jahr

Category4 (This value is dependent...

PFHD2.47 x 10⁻⁸ (This value is ...

Breaking capacity according to UL2 A 250 V AC / 1.5 A 24 V DC...

Performance LevelPL e (This value is depende...

Fusing10AgG

Cumulative currentmax.35 A For all contacts ...

Switching voltagemax.250 V

Switching currentmin.5 mA at 24V

Type of outputShort circuit-proof (On +24...

Output voltage24 V DC

Output currentmax.30 mA

Utilization category acc. to EN 60947-5-18A, 250V

LED indicatorOne operating voltage status...

Control current250 mA

Control voltage24 V 18,6 ... 26 V Start ...

Test voltage2,5 kV

Connection cross-section0,14 ... 2,5 mm² (Connectio...

Overvoltage category according to IEC EN 60664-13

Degree of contamination (external, according to EN 60947-1)2

Rated impulse withstand voltage Uimp4 kV

Rated insulation voltage Ui250 V

Operating voltage24 V -10% ... +10% (All t...

Connection rating4,5 W

Power consumption (apparent power)8,5 VA

Number of safety contacts7

Number of auxiliary contacts4

Number of monitoring contacts2

Contact materialAgSnO<sub>2</sub>

Length of control cable1000 m

ConnectionPlug-in connection terminals

Number of monitoring outputs2 semiconductor outputs

Ambient temperature-15 ... 40 °C

Housing materialPolyamide PA6.6

Mounting methodMounting rail 35mm according...

Mechanical life10 x 10⁶

Degree of protectionIP20

B10D-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Shock and vibration resistance-

Approach speed-

Switching frequency-

Ready delay-

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

In compliance with-

Mission time20 y

Number of switching cycles-

Category4

PFHD4.1 x 10 ⁻⁹

Breaking capacity according to UL-

Performance LevelPL e

Fusing0,25 ... 8 A

Cumulative current-

Switching voltage-

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Output voltage0 ... 1 V DC

Output current-

Utilization category acc. to EN 60947-5-1-

LED indicator-

Control current-

Control voltage-

Test voltage-

Connection cross-section-

Overvoltage category according to IEC EN 60664-1-

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Operating voltage5 ... 24 V

Connection rating1 W

Power consumption (apparent power)-

Number of safety contacts-

Number of auxiliary contacts-

Number of monitoring contacts-

Contact material-

Length of control cable-

Connection2 plug connectors M12, 5-pin

Number of monitoring outputs-

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Mounting method-

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

098827
1 in stock
098827
Euchner

098827 Euchner - Safety switch STP-TWIN with door monitoring contact

Weight1.68873892 lb

SeriesSTP

Product ClassSafety switch

In compliance with-

Mission time-

Number of switching cycles-

CategoryDepending on external contro...

PFHDDepending on external contro...

Breaking capacity according to UL-

Performance LevelDepending on external contro...

Fusing-

Cumulative current-

Switching voltage12 V

Switching current1 mA

Type of output-

Output voltage-

Output current-

Utilization category acc. to EN 60947-5-14A 230V

LED indicator-

Control current-

Control voltage-

Test voltage-

Connection cross-section0,34 ... 1,5 mm²

Overvoltage category according to IEC EN 60664-1-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp2,5 kV

Rated insulation voltage Ui250 V

Operating voltage-

Connection rating8 W

Power consumption (apparent power)-

Number of safety contacts-

Number of auxiliary contacts-

Number of monitoring contacts-

Contact materialSilver alloy, gold flashed

Length of control cable-

ConnectionM20 x 1.5

Number of monitoring outputs-

Ambient temperature-20 ... 55 °C

Housing materialReinforced thermoplastic

Mounting method-

Mechanical life1 x 10⁶

Degree of protectionIP67

B10D5 x 10⁶

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel5 mm

Test-pulse interval-

Extraction force30 N

Test pulses-

Actuating force35 N

Installation orientationAny

Shock and vibration resistance-

Approach speedmax.20 m/min

Switching frequency-

Ready delay-

Additional featureWith mechanical key release ...

Solenoid duty cycle100 %

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Locking force FZh2000 N

Retention force20 N

Locking force Fmax2500 N

Actuation frequencymax.1200 1/h

Guard locking principleClosed-circuit current princ...

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Number of guard lock monitoring NO contacts1

Number of guard lock monitoring positively driven contacts2

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 097225?
The price of 097225 on MQ Automation is $638.40. Order now.

Out if stock but available for backorder.

097225 Euchner - Basic device ESM-BA7.., 7 safety contacts, 4 auxiliary contacts, 2 monitoring contacts, cat. 4

What can I help you find today?

Recommended parts