097224 Euchner Safety Relays

097224 on MQ Automation
Euchner
  • 097224
  • 097224
  • 097224

Part#:097224

Alt. Part#:ESM-BA701

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

Product description

097224 Euchner - Basic device ESM-BA7.., 7 safety contacts, 4 auxiliary contacts, 2 monitoring contacts, cat. 4

Product Details

  • Weight
    0.8928711 lb
  • Series
    ESM
  • Product Class
    safety relay
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Number of switching cycles
    max.350000 1/Jahr
  • PFHD
    2.47 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (This value is dependent on the number of switching cycles and the switching current.)
  • Category
    4 (This value is dependent on the number of switching cycles and the switching current.)
  • In compliance with
    EN ISO 13849-1:2015 ; EN 62061:2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS)
  • Output current
    max.30 mA
  • Output voltage
    24 V DC
  • Fusing
    10AgG
  • Cumulative current
    max.35 A For all contacts (With a housing distance of 10mm. 20A closely spaced at 40°C)
  • Switching voltage
    max.250 V
  • Switching current
    min.5 mA at 24V
  • Breaking capacity according to UL
    2 A 250 V AC / 1.5 A 24 V DC per contact
  • LED indicator
    One operating voltage status display (Pwr), two status displays (green) for relays K1 and K2
  • Utilization category acc. to EN 60947-5-1
    8A, 250V
  • Type of output
    Relay contacts, floating
  • Control current
    250 mA
  • Control voltage
    24 V 18,6 ... 26 V Start button
  • Test voltage
    2,5 kV
  • Connection rating
    4,5 W
  • Connection cross-section
    0,14 ... 2,5 mm² (Connection terminal (size))
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Operating voltage
    24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Number of monitoring contacts
    2
  • Number of safety contacts
    7
  • Overvoltage category according to IEC EN 60664-1
    3
  • Number of auxiliary contacts
    4
  • Power consumption (apparent power)
    8,5 VA
  • Rated insulation voltage Ui
    250 V
  • Rated impulse withstand voltage Uimp
    4 kV
  • Length of control cable
    1000 m
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Number of monitoring outputs
    2 semiconductor outputs
  • Contact material
    AgSnO2
  • Mechanical life
    10 x 10⁶
  • Connection
    Connection terminals
  • Housing material
    Polyamide PA6.6
  • Degree of protection
    IP20
  • Weight
    0,35 kg
  • Ambient temperature
    -15 ... 40 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 097224 on MQ Automation is $638.40. Order now.


About the product

ESM-BA.. Use up to category 4 according to EN ISO 13849-1;LED status indicators;1-channel or 2-channel control;7 redundant safety contacts;4 auxiliary contacts;2 monitoring contacts;Short circuit and earth fault/ground fault monitoring optional


Manufacturer warranty

097224 Euchner

$638.40

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$638.40

$638.40 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 097224 with other products

Weight

Series

Product Class

Mission time

Number of switching cycle...

PFHD

Performance Level

Category

In compliance with

Output current

Output voltage

Fusing

Cumulative current

Switching voltage

Switching current

Breaking capacity accordi...

LED indicator

Utilization category acc....

Type of output

Control current

Control voltage

Test voltage

Connection rating

Connection cross-section

Degree of contamination (...

Operating voltage

Number of monitoring cont...

Number of safety contacts

Overvoltage category acco...

Number of auxiliary conta...

Power consumption (appare...

Rated insulation voltage ...

Rated impulse withstand v...

Length of control cable

Mounting method

Number of monitoring outp...

Contact material

Mechanical life

Connection

Housing material

Degree of protection

Ambient temperature

B10D

For the approval acc. to ...

Version

Operating current

Switching element

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Safety class

Turn-on time

Switching load

EMC protection requiremen...

Utilization category acc....

Current consumption

Operating voltage DC

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Installation orientation

Shock and vibration resis...

Approach speed

Switching frequency

Ready delay

Additional feature

Solenoid duty cycle

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Locking force FZh

Retention force

Locking force Fmax

Actuation frequency

Guard locking principle

Number of door position N...

Switching principle

Number of guard lock moni...

Number of guard lock moni...

Selected product

097224
0 in stock
097224
Euchner

097224 Euchner - Basic device ESM-BA7.., 7 safety contacts, 4 auxiliary contacts, 2 monitoring conta...

Weight0.8928711 lb

SeriesESM

Product Classsafety relay

Mission time20 y (This value is depend...

Number of switching cyclesmax.350000 1/Jahr

PFHD2.47 x 10⁻⁸ (This value is ...

Performance LevelPL e (This value is depende...

Category4 (This value is dependent...

In compliance withEN ISO 13849-1:2015 ; EN 620...

Output currentmax.30 mA

Output voltage24 V DC

Fusing10AgG

Cumulative currentmax.35 A For all contacts ...

Switching voltagemax.250 V

Switching currentmin.5 mA at 24V

Breaking capacity according to UL2 A 250 V AC / 1.5 A 24 V DC...

LED indicatorOne operating voltage status...

Utilization category acc. to EN 60947-5-18A, 250V

Type of outputRelay contacts, floating

Control current250 mA

Control voltage24 V 18,6 ... 26 V Start ...

Test voltage2,5 kV

Connection rating4,5 W

Connection cross-section0,14 ... 2,5 mm² (Connectio...

Degree of contamination (external, according to EN 60947-1)2

Operating voltage24 V -10% ... +10% (All t...

Number of monitoring contacts2

Number of safety contacts7

Overvoltage category according to IEC EN 60664-13

Number of auxiliary contacts4

Power consumption (apparent power)8,5 VA

Rated insulation voltage Ui250 V

Rated impulse withstand voltage Uimp4 kV

Length of control cable1000 m

Mounting methodMounting rail 35mm according...

Number of monitoring outputs2 semiconductor outputs

Contact materialAgSnO<sub>2</sub>

Mechanical life10 x 10⁶

ConnectionConnection terminals

Housing materialPolyamide PA6.6

Degree of protectionIP20

Ambient temperature-15 ... 40 °C

B10D-

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Shock and vibration resistance-

Approach speed-

Switching frequency-

Ready delay-

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Number of switching cycles-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

In compliance with-

Output current-

Output voltage0 ... 1 V DC

Fusing0,25 ... 8 A

Cumulative current-

Switching voltage-

Switching current1 ... 150 mA

Breaking capacity according to UL-

LED indicator-

Utilization category acc. to EN 60947-5-1-

Type of output2 semiconductor outputs, p-s...

Control current-

Control voltage-

Test voltage-

Connection rating1 W

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Operating voltage5 ... 24 V

Number of monitoring contacts-

Number of safety contacts-

Overvoltage category according to IEC EN 60664-1-

Number of auxiliary contacts-

Power consumption (apparent power)-

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Length of control cable-

Mounting method-

Number of monitoring outputs-

Contact material-

Mechanical life1 x 10⁶

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Locking force FZh-

Retention force-

Locking force Fmax-

Actuation frequency-

Guard locking principle-

Number of door position NC contacts-

Switching principle-

Number of guard lock monitoring NO contacts-

Number of guard lock monitoring positively driven contacts-

098827
1 in stock
098827
Euchner

098827 Euchner - Safety switch STP-TWIN with door monitoring contact

Weight1.68873892 lb

SeriesSTP

Product ClassSafety switch

Mission time-

Number of switching cycles-

PFHDDepending on external contro...

Performance LevelDepending on external contro...

CategoryDepending on external contro...

In compliance with-

Output current-

Output voltage-

Fusing-

Cumulative current-

Switching voltage12 V

Switching current1 mA

Breaking capacity according to UL-

LED indicator-

Utilization category acc. to EN 60947-5-14A 230V

Type of output-

Control current-

Control voltage-

Test voltage-

Connection rating8 W

Connection cross-section0,34 ... 1,5 mm²

Degree of contamination (external, according to EN 60947-1)-

Operating voltage-

Number of monitoring contacts-

Number of safety contacts-

Overvoltage category according to IEC EN 60664-1-

Number of auxiliary contacts-

Power consumption (apparent power)-

Rated insulation voltage Ui250 V

Rated impulse withstand voltage Uimp2,5 kV

Length of control cable-

Mounting method-

Number of monitoring outputs-

Contact materialSilver alloy, gold flashed

Mechanical life1 x 10⁶

ConnectionM20 x 1.5

Housing materialReinforced thermoplastic

Degree of protectionIP67

Ambient temperature-20 ... 55 °C

B10D5 x 10⁶

For the approval acc. to UL the following applies-

Version-

Operating current-

Switching element-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Safety class-

Turn-on time-

Switching load-

EMC protection requirements-

Utilization category acc. to EN 60947-5-2-

Current consumption-

Operating voltage DC-

Overtravel5 mm

Test-pulse interval-

Extraction force30 N

Test pulses-

Actuating force35 N

Installation orientationAny

Shock and vibration resistance-

Approach speedmax.20 m/min

Switching frequency-

Ready delay-

Additional featureWith mechanical key release ...

Solenoid duty cycle100 %

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Locking force FZh2000 N

Retention force20 N

Locking force Fmax2500 N

Actuation frequencymax.1200 1/h

Guard locking principleClosed-circuit current princ...

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Number of guard lock monitoring NO contacts1

Number of guard lock monitoring positively driven contacts2

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 097224?
The price of 097224 on MQ Automation is $638.40. Order now.

Out if stock but available for backorder.

097224 Euchner - Basic device ESM-BA7.., 7 safety contacts, 4 auxiliary contacts, 2 monitoring contacts, cat. 4

What can I help you find today?

Recommended parts