085536 Euchner Safety Accessories
Part#:085536
Alt. Part#:CMS-E-AR
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Mar 15, 2025
Product description
085536 Euchner - Evaluation unit CMS-E-AR, 1 safety contact
Product Details
- Weight 0.37699002 lb
- Series CMS
- Product Class Safety System
- Assured operating distance Sao min.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- Assured release distance Sar max.18 mm (The assured switch-off distance sar corresponds to the reset distance.)
- Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
- Center offset 2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- Number of switching cycles max.96000 1/Jahr
- PFHD 4.3 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
- Performance Level PL d (This value is dependent on the number of switching cycles and the switching current.)
- In compliance with EN ISO 13849-1: 2015 ; EN 50178: 1997 ; EN 60204-1: 2006/A1: 2009 ; EN ISO 14119: 2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1:2011; EN 60947-5-3: 2013
- Breaking capacity (VA) max.750 VA
- Risk time according to EN 60947-5-3 max.10 ms
- Category 3 (This value is dependent on the number of switching cycles and the switching current.)
- Switching load Input: 24V DC ; output: 24V DC
- Switching voltage max.250 V
- Utilization category acc. to EN 60947-5-1 0.9A , 250V (Max. switching current per contact)
- Rated insulation voltage Ui 250 V
- Switching current 2 ... 3000 mA
- Current consumption 70 mA
- Type of output Relay contacts, floating (NO)
- Fusing 0,75 A Automatically resetting fuse PTC
- Connection cross-section 0,14 ... 2,5 mm²
- LED indicator 1 indicator LED Power (UB) and 2 status indicators for the read heads (D1/D2)
- Degree of contamination (external, according to EN 60947-1) 2
- Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
- Ambient temperature 0 ... 50 °C
- Degree of protection Terminals IP20 / housing IP40
- Number of safety contacts 1
- Mechanical life 10 x 10⁶
- Operating voltage 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
- Connection Connection terminals, plug-in
- Housing material Polycarbonate (PC)
- Weight 0,13 kg
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 085536 on MQ Automation is $203.12. Order now.
About the product
Up to 30 read heads can be connected;1 safety contact
This item can ship in 3-5 days!
Manufacturer warranty
085536 Euchner
$203.12
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$203.12
$203.12 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 085536 with other products
Weight
Series
Product Class
Assured operating distanc...
Assured release distance ...
Mission time
Center offset
Number of switching cycle...
PFHD
Performance Level
In compliance with
Breaking capacity (VA)
Risk time according to EN...
Category
Switching load
Switching voltage
Utilization category acc....
Rated insulation voltage ...
Switching current
Current consumption
Type of output
Fusing
Connection cross-section
LED indicator
Degree of contamination (...
Mounting method
Ambient temperature
Degree of protection
Number of safety contacts
Mechanical life
Operating voltage
Connection
Housing material
Switching hysteresis
Operating distance
For the approval acc. to ...
Repeat accuracy R
Discrepancy time
Off-state current Ir
Utilization category acc....
Rated conditional short-c...
Test pulses
Test-pulse interval
Output voltage
Turn-on time
Rated impulse withstand v...
Safety class
EMC protection requiremen...
Extension of risk time ac...
Tightening torque
Installation orientation
Mounting distance
Operating voltage DC
Switching frequency
Ready delay
Cable ambient temperature...
Static bending radius
Shock and vibration resis...
Cable ambient temperature...
Dynamic bending radius
Additional feature
Solenoid duty cycle
Connection rating
Solenoid operating voltag...
Actuating force
Extraction force
Overtravel
Locking force Fmax
Approach speed
Retention force
Locking force FZh
Guard locking principle
Selected product
Weight0.37699002 lb
SeriesCMS
Product ClassSafety System
Assured operating distance Saomin.6 mm (Figure only appli...
Assured release distance Sarmax.18 mm (The assured swit...
Mission time20 y (This value is depend...
Center offset2,5 mm (Figure only applies...
Number of switching cyclesmax.96000 1/Jahr
PFHD4.3 x 10⁻⁸ (This value is d...
Performance LevelPL d (This value is depende...
In compliance withEN ISO 13849-1: 2015 ; EN 50...
Breaking capacity (VA)max.750 VA
Risk time according to EN 60947-5-3max.10 ms
Category3 (This value is dependent...
Switching loadInput: 24V DC ; output: 24V...
Switching voltagemax.250 V
Utilization category acc. to EN 60947-5-10.9A , 250V (Max. switching...
Rated insulation voltage Ui250 V
Switching current2 ... 3000 mA
Current consumption70 mA
Type of outputRelay contacts, floating (N...
Fusing0,75 A Automatically rese...
Connection cross-section0,14 ... 2,5 mm²
LED indicator1 indicator LED Power (UB) a...
Degree of contamination (external, according to EN 60947-1)2
Mounting methodMounting rail 35mm according...
Ambient temperature0 ... 50 °C
Degree of protectionTerminals IP20 / housing IP4...
Number of safety contacts1
Mechanical life10 x 10⁶
Operating voltage24 V -10% ... +10% (All t...
ConnectionConnection terminals, plug-i...
Housing materialPolycarbonate (PC)
Switching hysteresis-
Operating distance-
For the approval acc. to UL the following applies-
Repeat accuracy R-
Discrepancy time-
Off-state current Ir-
Utilization category acc. to EN 60947-5-2-
Rated conditional short-circuit current-
Test pulses-
Test-pulse interval-
Output voltage-
Turn-on time-
Rated impulse withstand voltage Uimp-
Safety class-
EMC protection requirements-
Extension of risk time according to EN 60947-5-3 per device-
Tightening torque-
Installation orientation-
Mounting distance-
Operating voltage DC-
Switching frequency-
Ready delay-
Cable ambient temperature (dynamic)-
Static bending radius-
Shock and vibration resistance-
Cable ambient temperature (static)-
Dynamic bending radius-
Additional feature-
Solenoid duty cycle-
Connection rating-
Solenoid operating voltage DC-
Actuating force-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Locking force FZh-
Guard locking principle-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 085536?
The price of 085536 on MQ Automation is $203.12. Order now.
Out if stock but available for backorder.
085536 Euchner - Evaluation unit CMS-E-AR, 1 safety contact
Similar products from: Safety Accessories
What can I help you find today?