085536 Euchner Safety Accessories

085536 on MQ Automation
Euchner
  • 085536
  • 085536
  • 085536

Part#:085536

Alt. Part#:CMS-E-AR

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

12 in stock

Mar 15, 2025

Product description

085536 Euchner - Evaluation unit CMS-E-AR, 1 safety contact

Product Details

  • Weight
    0.37699002 lb
  • Series
    CMS
  • Product Class
    Safety System
  • Assured operating distance Sao
    min.6 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
  • Assured release distance Sar
    max.18 mm (The assured switch-off distance sar corresponds to the reset distance.)
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Center offset
    2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
  • Number of switching cycles
    max.96000 1/Jahr
  • PFHD
    4.3 x 10⁻⁸ (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL d (This value is dependent on the number of switching cycles and the switching current.)
  • In compliance with
    EN ISO 13849-1: 2015 ; EN 50178: 1997 ; EN 60204-1: 2006/A1: 2009 ; EN ISO 14119: 2013; EN 6100-6-2: 2005; EN 6100-6-3: 2007/A1:2011; EN 60947-5-3: 2013
  • Breaking capacity (VA)
    max.750 VA
  • Risk time according to EN 60947-5-3
    max.10 ms
  • Category
    3 (This value is dependent on the number of switching cycles and the switching current.)
  • Switching load
    Input: 24V DC ; output: 24V DC
  • Switching voltage
    max.250 V
  • Utilization category acc. to EN 60947-5-1
    0.9A , 250V (Max. switching current per contact)
  • Rated insulation voltage Ui
    250 V
  • Switching current
    2 ... 3000 mA
  • Current consumption
    70 mA
  • Type of output
    Relay contacts, floating (NO)
  • Fusing
    0,75 A Automatically resetting fuse PTC
  • Connection cross-section
    0,14 ... 2,5 mm²
  • LED indicator
    1 indicator LED Power (UB) and 2 status indicators for the read heads (D1/D2)
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • Ambient temperature
    0 ... 50 °C
  • Degree of protection
    Terminals IP20 / housing IP40
  • Number of safety contacts
    1
  • Mechanical life
    10 x 10⁶
  • Operating voltage
    24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Connection
    Connection terminals, plug-in
  • Housing material
    Polycarbonate (PC)
  • Weight
    0,13 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 085536 on MQ Automation is $203.12. Order now.


About the product

Up to 30 read heads can be connected;1 safety contact


This item can ship in 3-5 days!

Manufacturer warranty

085536 Euchner

$203.12

Your price can be lower.
Log in or Create account to check your discount

Stock:

12

Select Qty:

$203.12

$203.12 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 085536 with other products

Weight

Series

Product Class

Assured operating distanc...

Assured release distance ...

Mission time

Center offset

Number of switching cycle...

PFHD

Performance Level

In compliance with

Breaking capacity (VA)

Risk time according to EN...

Category

Switching load

Switching voltage

Utilization category acc....

Rated insulation voltage ...

Switching current

Current consumption

Type of output

Fusing

Connection cross-section

LED indicator

Degree of contamination (...

Mounting method

Ambient temperature

Degree of protection

Number of safety contacts

Mechanical life

Operating voltage

Connection

Housing material

Switching hysteresis

Operating distance

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc....

Rated conditional short-c...

Test pulses

Test-pulse interval

Output voltage

Turn-on time

Rated impulse withstand v...

Safety class

EMC protection requiremen...

Extension of risk time ac...

Tightening torque

Installation orientation

Mounting distance

Operating voltage DC

Switching frequency

Ready delay

Cable ambient temperature...

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Additional feature

Solenoid duty cycle

Connection rating

Solenoid operating voltag...

Actuating force

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Locking force FZh

Guard locking principle

Selected product

085536
12 in stock
085536
Euchner

085536 Euchner - Evaluation unit CMS-E-AR, 1 safety contact

Weight0.37699002 lb

SeriesCMS

Product ClassSafety System

Assured operating distance Saomin.6 mm (Figure only appli...

Assured release distance Sarmax.18 mm (The assured swit...

Mission time20 y (This value is depend...

Center offset2,5 mm (Figure only applies...

Number of switching cyclesmax.96000 1/Jahr

PFHD4.3 x 10⁻⁸ (This value is d...

Performance LevelPL d (This value is depende...

In compliance withEN ISO 13849-1: 2015 ; EN 50...

Breaking capacity (VA)max.750 VA

Risk time according to EN 60947-5-3max.10 ms

Category3 (This value is dependent...

Switching loadInput: 24V DC ; output: 24V...

Switching voltagemax.250 V

Utilization category acc. to EN 60947-5-10.9A , 250V (Max. switching...

Rated insulation voltage Ui250 V

Switching current2 ... 3000 mA

Current consumption70 mA

Type of outputRelay contacts, floating (N...

Fusing0,75 A Automatically rese...

Connection cross-section0,14 ... 2,5 mm²

LED indicator1 indicator LED Power (UB) a...

Degree of contamination (external, according to EN 60947-1)2

Mounting methodMounting rail 35mm according...

Ambient temperature0 ... 50 °C

Degree of protectionTerminals IP20 / housing IP4...

Number of safety contacts1

Mechanical life10 x 10⁶

Operating voltage24 V -10% ... +10% (All t...

ConnectionConnection terminals, plug-i...

Housing materialPolycarbonate (PC)

Switching hysteresis-

Operating distance-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Turn-on time-

Rated impulse withstand voltage Uimp-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Installation orientation-

Mounting distance-

Operating voltage DC-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

Additional feature-

Solenoid duty cycle-

Connection rating-

Solenoid operating voltage DC-

Actuating force-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Guard locking principle-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Mission time20

Center offset-

Number of switching cycles-

PFHD1.9 x 10⁻⁹

Performance LevelPL e

In compliance with-

Breaking capacity (VA)-

Risk time according to EN 60947-5-3max.260 ms

Category4

Switching load-

Switching voltage-

Utilization category acc. to EN 60947-5-1-

Rated insulation voltage Ui75 V

Switching currentmax.50 mA

Current consumptionmax.50 mA (Without taking i...

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Connection cross-section-

LED indicator-

Degree of contamination (external, according to EN 60947-1)3

Mounting methodSurface mounting on metal

Ambient temperature-

Degree of protectionIP67

Number of safety contacts-

Mechanical life-

Operating voltage-

ConnectionConnection cable PUR, length...

Housing materialPlastic, PBT

Switching hysteresismin.1 mm

Operating distance19 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Installation orientationAny

Mounting distancemin.120 mm

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Additional feature-

Solenoid duty cycle-

Connection rating-

Solenoid operating voltage DC-

Actuating force-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Guard locking principle-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Assured operating distance Sao-

Assured release distance Sar-

Mission time20 y

Center offset-

Number of switching cycles-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

In compliance with-

Breaking capacity (VA)-

Risk time according to EN 60947-5-3max.260 ms

Category4

Switching load24V DC, class 2 (Alternativ...

Switching voltage-

Utilization category acc. to EN 60947-5-1-

Rated insulation voltage Ui50 V

Switching current1 ... 50 mA

Current consumption40 mA

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Connection cross-section-

LED indicator-

Degree of contamination (external, according to EN 60947-1)3

Mounting method-

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Number of safety contacts-

Mechanical life1 x 10⁶

Operating voltage-

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

Switching hysteresis-

Operating distance-

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated conditional short-circuit current-

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torque-

Installation orientationAny

Mounting distance-

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching frequencymax.0,5 Hz

Ready delay8 s

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-

Dynamic bending radius-

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 085536?
The price of 085536 on MQ Automation is $203.12. Order now.

Out if stock but available for backorder.

085536 Euchner - Evaluation unit CMS-E-AR, 1 safety contact

What can I help you find today?

Recommended parts