085530 Euchner Safety Proximity Sensors
Part#:085530
Alt. Part#:CMS-R-BXI-03V
Manufacturer:Euchner
Category:Safety Proximity Sensors
Product Lifecycle:Active
Mar 16, 2025
Product description
085530 Euchner - Read heads CMS design B - with NC/NO contacts, PVC
Product Details
- Weight 0.3968316 lb
- Series CMS read heads
- Product Class Safety System
- Switching voltage according to UL max.24 V AC/DC
- In compliance with EN ISO 13849-1:2015; EN 50178:1997; EN 60204-1:2006/A1:2009; EN ISO 14119:2013; EN 61000-6-2:2005; EN 61000-6-3:2007/A1:2011; EN 60947-5-3:2013
- Assured release distance Sar max.12 mm (The assured switch-off distance s_ar corresponds to the reset distance.)
- Assured operating distance Sao min.3 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
- Repeat accuracy R max.10 %
- Switching characteristics NO + NC
- Switching current 8 ... 500 mA
- Switching voltage 24 V
- Rated impulse withstand voltage Uimp 1,5 kV
- Method of operation Magnetic, reed contact
- Cable length 3 m
- Rated insulation voltage Ui 26,4 V
- Connection Hard-wired encapsulated cable with cable end sleeves 0.34mm²
- Number of NO contacts 1 NO contact
- Weight 0,16 kg
- Tightening torque 0,4 ... 0,5 Nm
- Number of NC contacts 1 NC contact
- Installation orientation Any, pay attention to marking (During mounting it is to be ensured the marking arrows on actuator and read head are opposite each other.)
- Design B
- Ambient temperature -20 ... 60 °C
- Degree of protection IP67
- Mechanical life 100 x 10⁶
- Material PVC
- Housing material Fiber glass reinforced PPS
- Shock and vibration resistance In acc. with EN 60947-5-3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 085530 on MQ Automation is $60.32. Order now.
About the product
In combination with evaluation units CMS-E-BR/CMS-E-ER/CMS-E-FR;Cube-shaped version, 36 x 26 mm;Connecting cable;Cable type: PVC
This item can ship in 3-5 days!
Manufacturer warranty
085530 Euchner
$60.32
Your price can be lower.
Log in or Create account to check your discount
Stock:
Select Qty:
$60.32
$60.32 each
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 085530 with other products
Weight
Series
Product Class
Switching voltage accordi...
In compliance with
Assured release distance ...
Assured operating distanc...
Repeat accuracy R
Switching characteristics
Switching current
Switching voltage
Rated impulse withstand v...
Method of operation
Cable length
Rated insulation voltage ...
Connection
Number of NO contacts
Tightening torque
Number of NC contacts
Installation orientation
Design
Ambient temperature
Degree of protection
Mechanical life
Material
Housing material
Shock and vibration resis...
Switching hysteresis
Operating distance
Mission time
PFHD
For the approval acc. to ...
Additional feature
Performance Level
Category
Discrepancy time
Off-state current Ir
Rated conditional short-c...
Test-pulse interval
Utilization category acc....
Test pulses
Output voltage
Type of output
Turn-on time
Risk time according to EN...
Safety class
EMC protection requiremen...
Degree of contamination (...
Fusing
Operating voltage DC
Switching frequency
Extension of risk time ac...
Current consumption
Ready delay
Mounting method
Mounting distance
Cable ambient temperature...
Cable ambient temperature...
Dynamic bending radius
Static bending radius
Selected product
Weight0.3968316 lb
SeriesCMS read heads
Product ClassSafety System
Switching voltage according to ULmax.24 V AC/DC
In compliance withEN ISO 13849-1:2015; EN 5017...
Assured release distance Sarmax.12 mm (The assured swit...
Assured operating distance Saomin.3 mm (Figure only appli...
Repeat accuracy Rmax.10 %
Switching characteristicsNO + NC
Switching current8 ... 500 mA
Switching voltage24 V
Rated impulse withstand voltage Uimp1,5 kV
Method of operationMagnetic, reed contact
Cable length3 m
Rated insulation voltage Ui26,4 V
ConnectionHard-wired encapsulated cabl...
Number of NO contacts1 NO contact
Tightening torque0,4 ... 0,5 Nm
Number of NC contacts1 NC contact
Installation orientationAny, pay attention to markin...
DesignB
Ambient temperature-20 ... 60 °C
Degree of protectionIP67
Mechanical life100 x 10⁶
MaterialPVC
Housing materialFiber glass reinforced PPS
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching hysteresis-
Operating distance-
Mission time-
PFHD-
For the approval acc. to UL the following applies-
Additional feature-
Performance Level-
Category-
Discrepancy time-
Off-state current Ir-
Rated conditional short-circuit current-
Test-pulse interval-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Output voltage-
Type of output-
Turn-on time-
Risk time according to EN 60947-5-3-
Safety class-
EMC protection requirements-
Degree of contamination (external, according to EN 60947-1)-
Fusing-
Operating voltage DC-
Switching frequency-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Ready delay-
Mounting method-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Static bending radius-
Weight0.23589434 lb
SeriesCES-AR
Product ClassSafety System
Switching voltage according to UL-
In compliance with-
Assured release distance Sarmax.60 mm
Assured operating distance Sao6
Repeat accuracy R≤ 10
Switching characteristics-
Switching currentmax.50 mA
Switching voltage-
Rated impulse withstand voltage Uimp1,5 kV
Method of operation-
Cable length-
Rated insulation voltage Ui300 V
ConnectionConnection cable PUR, length...
Number of NO contacts-
Tightening torquemax.0,8 Nm
Number of NC contacts-
Installation orientationAny
Design-
Ambient temperature-
Degree of protectionIP67
Mechanical life-
MaterialNBR 80 ±5 Shore
Housing materialPlastic, PBT
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching hysteresismin.1 mm
Operating distance11 mm
Mission time20
PFHD4.1 x 10⁻⁹
For the approval acc. to UL the following appliesOperation only with UL class...
Additional featureRubber support included
Performance LevelPL e
Category4
Discrepancy timemax.10 ms
Off-state current Irmax.0,25 mA
Rated conditional short-circuit current100 A
Test-pulse intervalmin.140 ms
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Test pulsesmax.1,0 ms (Applies for a l...
Output voltage0,8 x UB ... UB V DC
Type of outputSemiconductor output, p-swit...
Turn-on timemax.400 ms
Risk time according to EN 60947-5-3max.260 ms
Safety classIII
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Degree of contamination (external, according to EN 60947-1)3
Fusing0,25 ... 8 A
Operating voltage DC24 V DC 15% ... 15% Regu...
Switching frequencymax.1 Hz
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Current consumptionmax.35 mA (Without taking i...
Ready delay10 s
Mounting methodSurface mounting on metal
Mounting distancemin.80 mm
Cable ambient temperature (static)-25 ... 65 °C
Cable ambient temperature (dynamic)-25 ... 65 °C
Dynamic bending radius10 x cable diameter
Static bending radius5 x cable diameter

105748
Euchner
105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR
Weight0.29100984 lb
SeriesCES-AR
Product ClassSafety System
Switching voltage according to UL-
In compliance with-
Assured release distance Sarmax.60 mm
Assured operating distance Saomin.14 mm
Repeat accuracy R≤ 10
Switching characteristics-
Switching currentmax.50 mA
Switching voltage-
Rated impulse withstand voltage Uimp1,5 kV
Method of operation-
Cable length-
Rated insulation voltage Ui75 V
ConnectionConnection cable PUR, length...
Number of NO contacts-
Tightening torquemax.1 Nm
Number of NC contacts-
Installation orientationAny
Design-
Ambient temperature-
Degree of protectionIP67
Mechanical life-
Material-
Housing materialPlastic, PBT
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching hysteresismin.1 mm
Operating distance19 mm
Mission time20
PFHD1.9 x 10⁻⁹
For the approval acc. to UL the following appliesOperation only with UL class...
Additional feature-
Performance LevelPL e
Category4
Discrepancy timemax.10 ms
Off-state current Irmax.0,25 mA
Rated conditional short-circuit current100 A
Test-pulse intervalmin.140 ms
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Test pulsesmax.1 ms (Applies for a loa...
Output voltage0,8 x UB ... UB V DC
Type of outputp-switching, short circuit-p...
Turn-on timemax.400 ms
Risk time according to EN 60947-5-3max.260 ms
Safety classIII
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Degree of contamination (external, according to EN 60947-1)3
Fusing0,25 ... 8 A
Operating voltage DC24 V DC 15% ... 15% Regu...
Switching frequencymax.1 Hz
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Current consumptionmax.50 mA (Without taking i...
Ready delay10 s
Mounting methodSurface mounting on metal
Mounting distancemin.120 mm
Cable ambient temperature (static)-25 ... 65 °C
Cable ambient temperature (dynamic)-25 ... 65 °C
Dynamic bending radius10 x cable diameter
Static bending radius5 x cable diameter
Weight0.3968316 lb
SeriesCMS read heads
Product ClassSafety System
Switching voltage according to ULmax.24 V AC/DC
In compliance withEN ISO 13849-1:2015; EN 5017...
Assured release distance Sarmax.12 mm (The assured swit...
Assured operating distance Saomin.3 mm (Figure only appli...
Repeat accuracy Rmax.10 %
Switching characteristicsNO + NC
Switching current8 ... 500 mA
Switching voltage24 V
Rated impulse withstand voltage Uimp1,5 kV
Method of operationMagnetic, reed contact
Cable length3 m
Rated insulation voltage Ui26,4 V
ConnectionHard-wired encapsulated cabl...
Number of NO contacts1 NO contact
Tightening torque0,4 ... 0,5 Nm
Number of NC contacts1 NC contact
Installation orientationAny, pay attention to markin...
DesignB
Ambient temperature-20 ... 60 °C
Degree of protectionIP67
Mechanical life100 x 10⁶
MaterialPVC
Housing materialFiber glass reinforced PPS
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching hysteresis-
Operating distance-
Mission time-
PFHD-
For the approval acc. to UL the following applies-
Additional feature-
Performance Level-
Category-
Discrepancy time-
Off-state current Ir-
Rated conditional short-circuit current-
Test-pulse interval-
Utilization category acc. to EN 60947-5-2-
Test pulses-
Output voltage-
Type of output-
Turn-on time-
Risk time according to EN 60947-5-3-
Safety class-
EMC protection requirements-
Degree of contamination (external, according to EN 60947-1)-
Fusing-
Operating voltage DC-
Switching frequency-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Ready delay-
Mounting method-
Mounting distance-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Dynamic bending radius-
Static bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 085530?
The price of 085530 on MQ Automation is $60.32. Order now.
Out if stock but available for backorder.
085530 Euchner - Read heads CMS design B - with NC/NO contacts, PVC
Similar products from: Safety Proximity Sensors
What can I help you find today?