072949 Euchner Pendant Control Stations

072949 on MQ Automation
Euchner

Part#:072949

Alt. Part#:HBAS-072949

Manufacturer:Euchner

Category:Pendant Control Stations

Product Lifecycle:Active

Product description

072949 Euchner - PENDANT STATION

Product Details

  • Weight
    3.3075 lb
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Additional feature
    (See manual)
  • Switching element
    1 NO contact each
  • Position
    See data sheets
  • Color
    -
  • Version
    Push button
  • Data rate
    9,6 kbit/s max.19,2 kbit/s (Automatic adjustment during initialization)
  • Special features
    -
  • Data interface
    RS422
  • Data protocol
    3964R, 8 data bits, even parity
  • Switching current
    max.100 mA
  • Switching voltage
    max.DC 50 V
  • Connecting cable
    23x0.14mm²
  • Shock and vibration resistance
    Acc. to EN 60068-2-27/-2-6
  • Current consumption
    max.100 mA (Without LEDs switched on)
  • Type of output
    RS422
  • Utilization category acc. to EN 60947-5-1
    30V/3A
  • Operating voltage DC
    24 V DC -20% ... 20%
  • Degree of protection
    250-12 (On the front)
  • Atmospheric humidity
    max.80 % rH
  • Material
    Polycarbonate
  • Cable length
    3,5 m (Extended)
  • Weight
    1,2 kg
  • Ambient temperature
    0 ... 50 °C
  • Connection
    Plug connector (19-pin, metal version)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 072949 on MQ Automation is $3,354.84. Order now.


Manufacturer warranty

072949 Euchner

$3,354.84

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,354.84

$3,354.84 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 072949 with other products

Weight

For the approval acc. to ...

Additional feature

Switching element

Position

Color

Version

Data rate

Special features

Data interface

Data protocol

Switching current

Switching voltage

Connecting cable

Shock and vibration resis...

Current consumption

Type of output

Utilization category acc....

Operating voltage DC

Degree of protection

Atmospheric humidity

Material

Cable length

Ambient temperature

Connection

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

Mission time

PFHD

Performance Level

Repeat accuracy R

Category

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Utilization category acc....

Test pulses

Output voltage

Turn-on time

Risk time according to EN...

Safety class

EMC protection requiremen...

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Fusing

Switching frequency

Extension of risk time ac...

Ready delay

Tightening torque

Installation orientation

Mounting method

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Housing material

Static bending radius

B10D

Operating current

Detent mechanism

Operating voltage

Switching load

Connection rating

Overtravel

Extraction force

Actuating force

Mechanical life

Approach speed

Selected product

072949
0 in stock
072949
Euchner

072949 Euchner - PENDANT STATION

Weight3.3075 lb

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature(See manual)

Switching element1 NO contact each

PositionSee data sheets

Color-

VersionPush button

Data rate9,6 kbit/s max.19,2 kbit/s...

Special features-

Data interfaceRS422

Data protocol3964R, 8 data bits, even par...

Switching currentmax.100 mA

Switching voltagemax.DC 50 V

Connecting cable23x0.14mm²

Shock and vibration resistanceAcc. to EN 60068-2-27/-2-6

Current consumptionmax.100 mA (Without LEDs sw...

Type of outputRS422

Utilization category acc. to EN 60947-5-130V/3A

Operating voltage DC24 V DC -20% ... 20%

Degree of protection250-12 (On the front)

Atmospheric humiditymax.80 % rH

MaterialPolycarbonate

Cable length3,5 m (Extended)

Ambient temperature0 ... 50 °C

ConnectionPlug connector (19-pin, met...

Series-

Product Class-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Mission time-

PFHD-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Output voltage-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Ready delay-

Tightening torque-

Installation orientation-

Mounting method-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Housing material-

Static bending radius-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

Switching load-

Connection rating-

Overtravel-

Extraction force-

Actuating force-

Mechanical life-

Approach speed-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Switching element-

Position-

Color-

Version-

Data rate-

Special features-

Data interface-

Data protocol-

Switching currentmax.50 mA

Switching voltage-

Connecting cable-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumptionmax.35 mA (Without taking i...

Type of outputSemiconductor output, p-swit...

Utilization category acc. to EN 60947-5-1-

Operating voltage DC24 V DC 15% ... 15% Regu...

Degree of protectionIP67

Atmospheric humidity-

MaterialNBR 80 ±5 Shore

Cable length-

Ambient temperature-

ConnectionConnection cable PUR, length...

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Mission time20

PFHD4.1 x 10⁻⁹

Performance LevelPL e

Repeat accuracy R≤ 10

Category4

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Mounting methodSurface mounting on metal

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

B10D-

Operating current-

Detent mechanism-

Operating voltage-

Switching load-

Connection rating-

Overtravel-

Extraction force-

Actuating force-

Mechanical life-

Approach speed-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Switching element2 pos. driven NC

Position-

Color-

VersionEmergency stop

Data rate-

Special features-

Data interface-

Data protocol-

Switching current1 ... 150 mA

Switching voltage-

Connecting cable-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumption40 mA

Type of output2 semiconductor outputs, p-s...

Utilization category acc. to EN 60947-5-1-

Operating voltage DC24 V DC -15% ... 15% Rev...

Degree of protectionIP65 (Screwed tight plug co...

Atmospheric humidity-

Material-

Cable length-

Ambient temperature-20 ... +55 °C

Connection2 plug connectors M12, 5-pin

SeriesMGBS-P-I-AP

Product ClassSafety System

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Repeat accuracy R10 %

Category4

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current-

Test-pulse intervalmin.100 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.0,3 ms (Applies for a l...

Output voltage0 ... 1 V DC

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Fusing0,25 ... 8 A

Switching frequencymax.0,5 Hz

Extension of risk time according to EN 60947-5-3 per device-

Ready delaymax.1 s

Tightening torque-

Installation orientationDoor hinge DIN right

Mounting method-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Housing materialFiber glass reinforced therm...

Static bending radius-

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

Switching load24V DC, class 2 (Alternativ...

Connection rating1 W

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Mechanical life1 x 10⁶

Approach speedmax.20 m/min

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 072949?
The price of 072949 on MQ Automation is $3,354.84. Order now.

Out if stock but available for backorder.

072949 Euchner - PENDANT STATION

What can I help you find today?

Recommended parts