072936 Euchner Pendant Control Stations

072936 on MQ Automation
Euchner

Part#:072936

Alt. Part#:HBA-072936

Manufacturer:Euchner

Category:Pendant Control Stations

Product Lifecycle:Active

Product description

072936 Euchner - PENDANT STATION

Product Details

  • Weight
    2.692305 lb
  • Position
    See data sheets
  • Color
    Red-yellow
  • Version
    Emergency stop
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Switching element
    2 positively driven contacts
  • Special features
    -
  • Breaking capacity (VA)
    max.1 VA (Common connection)
  • Pulses per revolution
    2x100
  • EMC protection requirements
    EN 61000-6-2, EN 61000-6-4
  • Type of output
    RS422
  • Connecting cable
    6x0.34mm² + 17x0.14mm² (Screened)
  • Operating voltage DC
    5 V DC -5% ... 5%
  • Switching current
    max.100 mA (Common connection)
  • Switching voltage
    max.AC 32 V
  • Detent positions per revolution
    100 (Magnetic detent mechanism)
  • Utilization category acc. to EN 60947-5-1
    24V DC / 3A
  • Shock and vibration resistance
    Acc. to EN 60068-2-27/-2-6
  • Cable length
    3,775 m (Extended)
  • Material
    Polycarbonate
  • Connection
    Plug connector (23-pin, metal version)
  • Weight
    1,2 kg
  • Ambient temperature
    0 ... 50 °C
  • Atmospheric humidity
    max.80 % rH
  • Degree of protection
    205-12 (On the front)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 072936 on MQ Automation is $1,716.30. Order now.


Manufacturer warranty

072936 Euchner

$1,716.30

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,716.30

$1,716.30 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 072936 with other products

Weight

Position

Color

Version

For the approval acc. to ...

Switching element

Special features

Breaking capacity (VA)

Pulses per revolution

EMC protection requiremen...

Type of output

Connecting cable

Operating voltage DC

Switching current

Switching voltage

Detent positions per revo...

Utilization category acc....

Shock and vibration resis...

Cable length

Material

Connection

Ambient temperature

Atmospheric humidity

Degree of protection

Series

Product Class

B10D

Mission time

PFHD

Performance Level

Category

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Safety class

Turn-on time

Switching load

Output voltage

Degree of contamination (...

Rated insulation voltage ...

Rated impulse withstand v...

Connection rating

Utilization category acc....

Fusing

Current consumption

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Installation orientation

Mechanical life

Housing material

Approach speed

Switching frequency

Ready delay

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

Additional feature

Rated conditional short-c...

Risk time according to EN...

Extension of risk time ac...

Tightening torque

Mounting method

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Static bending radius

Selected product

072936
0 in stock
072936
Euchner

072936 Euchner - PENDANT STATION

Weight2.692305 lb

PositionSee data sheets

ColorRed-yellow

VersionEmergency stop

For the approval acc. to UL the following appliesOperation only with UL class...

Switching element2 positively driven contacts

Special features-

Breaking capacity (VA)max.1 VA (Common connection...

Pulses per revolution2x100

EMC protection requirementsEN 61000-6-2, EN 61000-6-4

Type of outputRS422

Connecting cable6x0.34mm² + 17x0.14mm² (Scr...

Operating voltage DC5 V DC -5% ... 5%

Switching currentmax.100 mA (Common connecti...

Switching voltagemax.AC 32 V

Detent positions per revolution100 (Magnetic detent mecha...

Utilization category acc. to EN 60947-5-124V DC / 3A

Shock and vibration resistanceAcc. to EN 60068-2-27/-2-6

Cable length3,775 m (Extended)

MaterialPolycarbonate

ConnectionPlug connector (23-pin, met...

Ambient temperature0 ... 50 °C

Atmospheric humiditymax.80 % rH

Degree of protection205-12 (On the front)

Series-

Product Class-

B10D-

Mission time-

PFHD-

Performance Level-

Category-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Safety class-

Turn-on time-

Switching load-

Output voltage-

Degree of contamination (external, according to EN 60947-1)-

Rated insulation voltage Ui-

Rated impulse withstand voltage Uimp-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Fusing-

Current consumption-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Installation orientation-

Mechanical life-

Housing material-

Approach speed-

Switching frequency-

Ready delay-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Additional feature-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting method-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

Position-

Color-

VersionEmergency stop

For the approval acc. to UL the following appliesOperation only with UL class...

Switching element2 pos. driven NC

Special features-

Breaking capacity (VA)-

Pulses per revolution-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Type of output2 semiconductor outputs, p-s...

Connecting cable-

Operating voltage DC24 V DC -15% ... 15% Rev...

Switching current1 ... 150 mA

Switching voltage-

Detent positions per revolution-

Utilization category acc. to EN 60947-5-1-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable length-

Material-

Connection2 plug connectors M12, 5-pin

Ambient temperature-20 ... +55 °C

Atmospheric humidity-

Degree of protectionIP65 (Screwed tight plug co...

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Safety classIII

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Current consumption40 mA

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Additional feature-

Rated conditional short-circuit current-

Risk time according to EN 60947-5-3-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting method-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

Position-

Color-

Version-

For the approval acc. to UL the following appliesOperation only with UL class...

Switching element-

Special features-

Breaking capacity (VA)-

Pulses per revolution-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Type of outputSemiconductor output, p-swit...

Connecting cable-

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching currentmax.50 mA

Switching voltage-

Detent positions per revolution-

Utilization category acc. to EN 60947-5-1-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable length-

MaterialNBR 80 ±5 Shore

ConnectionConnection cable PUR, length...

Ambient temperature-

Atmospheric humidity-

Degree of protectionIP67

SeriesCES-AR

Product ClassSafety System

B10D-

Mission time20

PFHD4.1 x 10⁻⁹

Performance LevelPL e

Category4

Operating current-

Repeat accuracy R≤ 10

Detent mechanism-

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Operating voltage-

Safety classIII

Turn-on timemax.400 ms

Switching load-

Output voltage0,8 x UB ... UB V DC

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Connection rating-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Fusing0,25 ... 8 A

Current consumptionmax.35 mA (Without taking i...

Overtravel-

Test-pulse intervalmin.140 ms

Extraction force-

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force-

Installation orientationAny

Mechanical life-

Housing materialPlastic, PBT

Approach speed-

Switching frequencymax.1 Hz

Ready delay10 s

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Additional featureRubber support included

Rated conditional short-circuit current100 A

Risk time according to EN 60947-5-3max.260 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.0,8 Nm

Mounting methodSurface mounting on metal

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 072936?
The price of 072936 on MQ Automation is $1,716.30. Order now.

Out if stock but available for backorder.

072936 Euchner - PENDANT STATION

What can I help you find today?

Recommended parts