All categories
Automation components
All categories
Automation components
Lenze ESV222N02YXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40 °C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H203mm x W181mm x D172mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only, it has a frame size S1 with natural convection cooling (fan-less). The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface. The rated current is 9.6A at 240Vac, supporting both single-phase and 3-phase networks. The rated active power is 2.2kW (240Vac), equivalent to 3HP (240Vac).
Quick Quote
Lenze ESV751N04TXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, with dimensions of H203mm x W160mm x D114mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its analog inputs consist of 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. Digital inputs include 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only, it has a frame size R1 with natural convection cooling (fan-less). The supply voltage is 400Vac / 480Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface, has a rated current of 2.4A (400Vac) and 2.1A (480Vac), and operates on a 3-phase network (3P / 3AC). The rated active power is 0.75kW (400-480Vac), and the rated power is 1HP (400-480Vac).
Quick Quote
Lenze ESV752N02TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H250mm x W130mm x D160mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 analog input (0-10Vdc) at terminal 5, 1 analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) across terminals 1 (START/STOP), 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size H1, it has a supply voltage of 240Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 29A at 240Vac, for a 3-phase network, with a rated active power of 7.5kW and rated power of 10HP at 240Vac.
Quick Quote
Lenze ESV751N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40 °C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H190mm x W99mm x D111mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G1, it supports a supply voltage of 400Vac / 480Vac and a network frequency of 48-62 Hz input and 0-500 Hz output, without a communication interface. The rated current is 2.4A at 400Vac and 2.1A at 480Vac, for a 3-phase network. It delivers a rated active power of 0.75kW and a rated power of 1HP at 400-480Vac.
Quick Quote
Lenze ESV152N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H191mm x W99mm x D138mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G2, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 4A at 400Vac and 3.5A at 480Vac, for a 3-phase network. Rated active power is 1.5kW and rated power is 2HP for 400-480Vac.
Quick Quote
Lenze ESV402N02TXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring a robust design suitable for indoor environments. The dimensions are H254mm x W228mm x D203mm. It includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its input capabilities comprise 1 analog input (0-10Vdc) at terminal 5, 1 analog input (4-20mA) at terminal 25, and multiple digital inputs for versatile connectivity. Protection functions include earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use with a frame size V1 and natural convection cooling (fan-less), it has a supply voltage of 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). This model does not include a communication interface, has a rated current of 16.5A at 240Vac, operates on a 3-phase network (3P / 3AC), and delivers a rated active power of 4kW and rated power of 5HP at 240Vac.
Quick Quote
Lenze ESV402N02TXE is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring suitability for both indoor and outdoor use. The dimensions are H254mm x W228mm x D203mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs for versatile connectivity. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed with a frame size V1 for natural convection cooling (fan-less), it supports a supply voltage of 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). Despite lacking a communication interface, it operates on a 3-phase network (3P / 3AC), with a rated current of 16.5A (240Vac), rated active power of 4kW (240Vac), and rated power of 5HP (240Vac).
Quick Quote
Lenze ESV751N01SXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H190mm x W99mm x D111mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 analog input (0-10Vdc) at terminal 5 and 1 analog input (4-20mA) at terminal 25. There are multiple digital inputs: 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G1, it supports a supply voltage of 120Vac / 240Vac and a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 4.2A for both 120Vac and 240Vac, with a rated active power of 0.75kW and rated power of 1HP for the same voltage range. It is designed for a single-phase / 1P network.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
E84AVTCE1524SB0 LENZE E84AVTCE1524SB0 | Lenze | $2,210.63 | Quick Quote | ||
ESV222N02YXC Lenze ESV222N02YXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40 °C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65. The dimensions are H203mm x W181mm x D172mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only, it has a frame size S1 with natural convection cooling (fan-less). The supply voltage is 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface. The rated current is 9.6A at 240Vac, supporting both single-phase and 3-phase networks. The rated active power is 2.2kW (240Vac), equivalent to 3HP (240Vac). | Lenze | $784.00 | Quick Quote | ||
ESV751N04TXC Lenze ESV751N04TXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, with dimensions of H203mm x W160mm x D114mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its analog inputs consist of 1 x analog input (0-10Vdc) at terminal 5 and 1 x analog input (4-20mA) at terminal 25. Digital inputs include 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only, it has a frame size R1 with natural convection cooling (fan-less). The supply voltage is 400Vac / 480Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). It does not include a communication interface, has a rated current of 2.4A (400Vac) and 2.1A (480Vac), and operates on a 3-phase network (3P / 3AC). The rated active power is 0.75kW (400-480Vac), and the rated power is 1HP (400-480Vac). | Lenze | $727.33 | Quick Quote | ||
ESV752N02TXB Lenze ESV752N02TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H250mm x W130mm x D160mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 analog input (0-10Vdc) at terminal 5, 1 analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) across terminals 1 (START/STOP), 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size H1, it has a supply voltage of 240Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 29A at 240Vac, for a 3-phase network, with a rated active power of 7.5kW and rated power of 10HP at 240Vac. | Lenze | $1,261.04 | Quick Quote | ||
ESV751N04TXB Lenze ESV751N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40 °C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H190mm x W99mm x D111mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G1, it supports a supply voltage of 400Vac / 480Vac and a network frequency of 48-62 Hz input and 0-500 Hz output, without a communication interface. The rated current is 2.4A at 400Vac and 2.1A at 480Vac, for a 3-phase network. It delivers a rated active power of 0.75kW and a rated power of 1HP at 400-480Vac. | Lenze | $436.00 | Quick Quote | ||
ESV152N04TXB Lenze ESV152N04TXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H191mm x W99mm x D138mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs (PNP/NPN logic) at terminals 1 START/STOP, 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G2, it supports a supply voltage of 400Vac / 480Vac, network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 4A at 400Vac and 3.5A at 480Vac, for a 3-phase network. Rated active power is 1.5kW and rated power is 2HP for 400-480Vac. | Lenze | $549.78 | Quick Quote | ||
ESV402N02TXC Lenze ESV402N02TXC is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring a robust design suitable for indoor environments. The dimensions are H254mm x W228mm x D203mm. It includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, and its input capabilities comprise 1 analog input (0-10Vdc) at terminal 5, 1 analog input (4-20mA) at terminal 25, and multiple digital inputs for versatile connectivity. Protection functions include earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use with a frame size V1 and natural convection cooling (fan-less), it has a supply voltage of 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). This model does not include a communication interface, has a rated current of 16.5A at 240Vac, operates on a 3-phase network (3P / 3AC), and delivers a rated active power of 4kW and rated power of 5HP at 240Vac. | Lenze | $1,048.33 | Quick Quote | ||
ESV402N02TXE Lenze ESV402N02TXE is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 x analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 4X IP65, ensuring suitability for both indoor and outdoor use. The dimensions are H254mm x W228mm x D203mm. It includes 1 x digital output (NPN; 24Vdc / 50mA) at Terminal 14, 1 x analog input (0-10Vdc) at terminal 5, 1 x analog input (4-20mA) at terminal 25, and multiple digital inputs for versatile connectivity. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed with a frame size V1 for natural convection cooling (fan-less), it supports a supply voltage of 240Vac, with a network frequency of 48-62 Hz (input) and 0-500 Hz (output). Despite lacking a communication interface, it operates on a 3-phase network (3P / 3AC), with a rated current of 16.5A (240Vac), rated active power of 4kW (240Vac), and rated power of 5HP (240Vac). | Lenze | $1,197.21 | Quick Quote | ||
EPM-S400 INPUT MODULE, I/O SYSTEM 1000, 2 ANALOG INPUTS, 12-BIT, 0 TO 10 V | Lenze | $340.90 | Quick Quote | ||
ESV751N01SXB Lenze ESV751N01SXB is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for control cabinet or surface/wall mounting. It operates within an ambient air temperature range of -10 to +55 °C, with a derating of 2.5% per °C above +40°C. This model features 1 analog output (0-10Vdc) at Terminal 5, and its degree of protection is NEMA 1 IP31. The dimensions are H190mm x W99mm x D111mm. It also includes 1 digital output (NPN; 24Vdc / 50mA) at Terminal 14, alongside 1 analog input (0-10Vdc) at terminal 5 and 1 analog input (4-20mA) at terminal 25. There are multiple digital inputs: 1 x digital input (PNP/NPN logic) at terminal 1 for START/STOP, and 1 x digital input each at terminals 13A, 13B, 13C, and 13D. Protection functions cover earth fault, phase loss, overvoltage, under voltage, motor stalling, over temperature, motor overload (125% of FLA), and short circuit (SCCR = 200kA at rated voltage). Designed for indoor use only with a frame size G1, it supports a supply voltage of 120Vac / 240Vac and a network frequency of 48-62 Hz (input) and 0-500 Hz (output), without a communication interface. The rated current is 4.2A for both 120Vac and 240Vac, with a rated active power of 0.75kW and rated power of 1HP for the same voltage range. It is designed for a single-phase / 1P network. | Lenze | $430.68 | Quick Quote |