Product description

M8 female connector, front mounting SMD with M10 screw fastening

Product Details

  • Degree of protection
    IP67 (correctly plugged in and locked)
  • Material, knurls
    Nickel-plated brass
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.1
    27378000
  • ECLASS 9.0
    27379201
  • UNSPSC 19.0
    39121421
  • Mounting type
    Front mounting M10 x 0.75
  • Sealing material
    FKM (O-ring on housing)
  • ECLASS 4.0
    27378000
  • ECLASS 7.0
    27379201
  • UNSPSC 18.0
    39121421
  • Ambient temperature (operation)
    -40 °C ... 85 °C (without mechanical actuation)
  • ECLASS 10.0.1
    27371392
  • ECLASS 5.0
    27379100
  • ETIM 6.0
    EC002498
  • UNSPSC 20.0
    39121421
  • Note
    The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences ari
  • Material
    Brass, nickel-plated
  • ECLASS 11.0
    27371392
  • ECLASS 6.0
    27379200
  • UNSPSC 13.2
    39121421
  • Standards/regulations
    M8 connector IEC 61076-2-104 In line with
  • Thread type
    M10 x 0.75
  • Standards/specifications
    M8 connector IEC 61076-2-104 In line with
  • ECLASS 5.1
    27379100
  • ETIM 7.0
    EC002498
  • UNSPSC 21.0
    39121421

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

1412504 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

5

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 1412504 with other products

Degree of protection

Material, knurls

China RoHS

ECLASS 4.1

ECLASS 9.0

UNSPSC 19.0

Mounting type

Sealing material

ECLASS 4.0

ECLASS 7.0

UNSPSC 18.0

Ambient temperature (oper...

ECLASS 10.0.1

ECLASS 5.0

ETIM 6.0

UNSPSC 20.0

Note

Material

ECLASS 11.0

ECLASS 6.0

UNSPSC 13.2

Standards/regulations

Thread type

Standards/specifications

ECLASS 5.1

ETIM 7.0

UNSPSC 21.0

Product description

EAN

Packaging unit

eCl@ss 6.0/6.1

eCl@ss 8.0/8.1

Weight/packaging unit

Customs tariff number

Flange plate, size

Mounting plate

No. of locks

Lock version

Flange plate, qty

Number of doors

Lock Insert

Number of cam locks

Material thickness:

Dimensions

IK code

Supply includes

Protection category NEMA

Type rating according to ...

Surface finish

Color

Base material

Protection category IP to...

Interfering radiation

EMC rating

Current, Utilisation cate...

Voltage, Utilisation cate...

Current, Utilisation cate...

Versions

Voltage drop Ud, maximum

Current leakage Ir

Rated operating current (...

Operating current

Required rated short-circ...

Rated operating voltage, ...

Voltage type

Rated operating voltage

No-load supply current I0

Protection rating

Overvoltage category

Restistance to shock

Material temperature resi...

Resistance to vibrations ...

Material temperature resi...

Ambient temperature, mini...

Terminal Connector

Note (Repeat accuracy R)

Number of fail-safe digit...

Short-circuit recognition

Diagnostic output

Gross weight

Active area

Voltage, Utilisation cate...

Switching frequency, appr...

Output current, (fail-saf...

Rated operating voltage, ...

Degree of pollution to VD...

Rated impulse withstand v...

Rated insulation voltage ...

Material temperature resi...

Storage and transport tem...

Storage and transport tem...

Ambient temperature, maxi...

Ensured switch distance O...

Length of sensor

Height of sensor

Width of sensor

Ensured switch distance O...

Switch distance

Hysteresis (Switch distan...

Repeat accuracy R R

Mounting

Actuating panels

Number of semi-conductor ...

Number of LEDs

Cascadable

Integral System Diagnosti...

Duration of risk, maximum

Safety functions

Time to readiness, maximu...

Reaction time, maximum

Short circuit detection

Enclosure material

Sensor topology

Active principle

Standards

Installation conditions (...

Coding level according to...

general information

Housing construction form

Selected product

1412504
5 in stock
1412504
Phoenix Contact

M8 female connector, front mounting SMD with M10 screw fastening

Degree of protectionIP67 (correctly plugged in a...

Material, knurlsNickel-plated brass

China RoHSEnvironmentally Friendly Use...

ECLASS 4.127378000

ECLASS 9.027379201

UNSPSC 19.039121421

Mounting typeFront mounting M10 x 0.75

Sealing materialFKM (O-ring on housing)

ECLASS 4.027378000

ECLASS 7.027379201

UNSPSC 18.039121421

Ambient temperature (operation)-40 °C ... 85 °C (without me...

ECLASS 10.0.127371392

ECLASS 5.027379100

ETIM 6.0EC002498

UNSPSC 20.039121421

NoteThe electrical and mechanica...

MaterialBrass, nickel-plated

ECLASS 11.027371392

ECLASS 6.027379200

UNSPSC 13.239121421

Standards/regulationsM8 connector IEC 61076-2-104...

Thread typeM10 x 0.75

Standards/specificationsM8 connector IEC 61076-2-104...

ECLASS 5.127379100

ETIM 7.0EC002498

UNSPSC 21.039121421

Product description-

EAN-

Packaging unit-

eCl@ss 6.0/6.1-

eCl@ss 8.0/8.1-

Weight/packaging unit-

Customs tariff number-

Flange plate, size-

Mounting plate-

No. of locks-

Lock version-

Flange plate, qty-

Number of doors-

Lock Insert-

Number of cam locks-

Material thickness:-

Dimensions-

IK code-

Supply includes-

Protection category NEMA-

Type rating according to UL 50E-

Surface finish-

Color-

Base material-

Protection category IP to IEC 60 529-

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Voltage, Utilisation category DC13-

Current, Utilisation category DC13-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Ambient temperature, minimum-

Terminal Connector-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Gross weight-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ambient temperature, maximum-

Ensured switch distance ON Sao-

Length of sensor-

Height of sensor-

Width of sensor-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Mounting-

Actuating panels-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Enclosure material-

Sensor topology-

Active principle-

Standards-

Installation conditions (mechanical)-

Coding level according to ISO 14119-

general information-

Housing construction form-

1100000
8 in stock
1100000
Rittal

AX Compact enclosure, WHD: 1000x760x210 mm, sheet steel, with mounting plate, two-door, with two cam...

Degree of protection-

Material, knurls-

China RoHS-

ECLASS 4.1-

ECLASS 9.0-

UNSPSC 19.0-

Mounting type-

Sealing material-

ECLASS 4.0-

ECLASS 7.0-

UNSPSC 18.0-

Ambient temperature (operation)-

ECLASS 10.0.1-

ECLASS 5.0-

ETIM 6.0EC000261

UNSPSC 20.0-

Note-

MaterialHousing: Carbon steel, Door:...

ECLASS 11.0-

ECLASS 6.0-

UNSPSC 13.2-

Standards/regulations-

Thread type-

Standards/specifications-

ECLASS 5.1-

ETIM 7.0EC000261

UNSPSC 21.0-

Product descriptionAX Compact enclosure, WHD: 1...

EAN4028177813342

Packaging unit1 pc(s)

eCl@ss 6.0/6.127180101

eCl@ss 8.0/8.127180101

Weight/packaging unit49 kg ( 108lb. )

Customs tariff number94032080

Flange plate, size3

Mounting plateWidth: 945 mm ( 37" ), Heigh...

No. of locks2

Lock versionCam

Flange plate, qty2

Number of doors2

Lock Insert3 mm double-bit

Number of cam locks2

Material thickness:Housing: 1.5 mm, Door: 2 mm,...

DimensionsWidth: 1,000 mm ( 39" ), Hei...

IK codeIK10

Supply includesHousing with door(s), Flange...

Protection category NEMANEMA 1, 12

Type rating according to UL 50EType 1, 12

Surface finishHousing and door: Dipcoat pr...

ColorRAL 7035

Base materialCarbon steel

Protection category IP to IEC 60 529IP 55

Interfering radiation-

EMC rating-

Current, Utilisation category DC12-

Voltage, Utilisation category DC13-

Current, Utilisation category DC13-

Versions-

Voltage drop Ud, maximum-

Current leakage Ir-

Rated operating current (safety outputs)-

Operating current-

Required rated short-circuit current to EN 60947-5-1-

Rated operating voltage, minimum-

Voltage type-

Rated operating voltage-

No-load supply current I0-

Protection rating-

Overvoltage category-

Restistance to shock-

Material temperature resistance of the cable (in motion), minimum-

Resistance to vibrations to EN 60068-2-6-

Material temperature resistance (long-term), maximum-

Ambient temperature, minimum-

Terminal Connector-

Note (Repeat accuracy R)-

Number of fail-safe digital outputs-

Short-circuit recognition-

Diagnostic output-

Gross weight-

Active area-

Voltage, Utilisation category DC12-

Switching frequency, approx.-

Output current, (fail-safe output), maximum-

Rated operating voltage, maximum-

Degree of pollution to VDE 0100-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Material temperature resistance of the cable (at rest), minimum-

Storage and transport temperature, maximum-

Storage and transport temperature, minimum-

Ambient temperature, maximum-

Ensured switch distance ON Sao-

Length of sensor-

Height of sensor-

Width of sensor-

Ensured switch distance OFF Sar-

Switch distance-

Hysteresis (Switch distance), maximum-

Repeat accuracy R R-

Mounting-

Actuating panels-

Number of semi-conductor outputs with signaling function-

Number of LEDs-

Cascadable-

Integral System Diagnostics, status-

Duration of risk, maximum-

Safety functions-

Time to readiness, maximum-

Reaction time, maximum-

Short circuit detection-

Enclosure material-

Sensor topology-

Active principle-

Standards-

Installation conditions (mechanical)-

Coding level according to ISO 14119-

general information-

Housing construction form-

RSS 36-D-ST
1 in stock
RSS 36-D-ST
Schmersal

Safety sensors; Electronic safety sensors; Universal coding with RFID technology; 1 x connector sock...

Degree of protectionIP65 to EN 60529, IP67 to EN...

Material, knurls-

China RoHS-

ECLASS 4.1-

ECLASS 9.0-

UNSPSC 19.0-

Mounting type-

Sealing material-

ECLASS 4.0-

ECLASS 7.0-

UNSPSC 18.0-

Ambient temperature (operation)-

ECLASS 10.0.1-

ECLASS 5.0-

ETIM 6.0-

UNSPSC 20.0-

NoteThe cable section of the int...

Material-

ECLASS 11.0-

ECLASS 6.0-

UNSPSC 13.2-

Standards/regulations-

Thread type-

Standards/specifications-

ECLASS 5.1-

ETIM 7.0-

UNSPSC 21.0-

Product description-

EAN-

Packaging unit-

eCl@ss 6.0/6.1-

eCl@ss 8.0/8.1-

Weight/packaging unit-

Customs tariff number-

Flange plate, size-

Mounting plate-

No. of locks-

Lock version-

Flange plate, qty-

Number of doors-

Lock Insert-

Number of cam locks-

Material thickness:-

Dimensions-

IK code-

Supply includes-

Protection category NEMA-

Type rating according to UL 50E-

Surface finish-

Color-

Base material-

Protection category IP to IEC 60 529-

Interfering radiationIEC 61000-6-4

EMC ratingIEC 60947-3

Current, Utilisation category DC120.05 A

Voltage, Utilisation category DC1324 VDC

Current, Utilisation category DC130.05 A

Versionsp-type

Voltage drop Ud, maximum2 V

Current leakage Ir0.5 mA

Rated operating current (safety outputs)250 mA

Operating current600 mA

Required rated short-circuit current to EN 60947-5-1100 A

Rated operating voltage, minimum20.4 VDC

Voltage typeDC (direct current)

Rated operating voltage24 VDC −15 % / +10 %

No-load supply current I0100 mA

Protection ratingIII

Overvoltage categoryIII

Restistance to shock30 g / 11 ms

Material temperature resistance of the cable (in motion), minimum-10 °C

Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm

Material temperature resistance (long-term), maximum+105 °C

Ambient temperature, minimum-25 °C

Terminal ConnectorConnector M12, 8-pole

Note (Repeat accuracy R)Axial offset: The long side ...

Number of fail-safe digital outputs2

Short-circuit recognitionYes

Diagnostic outputYes

Gross weight80 g

Active arealateral

Voltage, Utilisation category DC1224 VDC

Switching frequency, approx.1 Hz

Output current, (fail-safe output), maximum0.25 A

Rated operating voltage, maximum26.4 VDC

Degree of pollution to VDE 01003

Rated impulse withstand voltage Uimp0.8 kV

Rated insulation voltage Ui32 VDC

Material temperature resistance of the cable (at rest), minimum-30 °C

Storage and transport temperature, maximum+85 °C

Storage and transport temperature, minimum-25 °C

Ambient temperature, maximum+70 °C

Ensured switch distance ON Sao10 mm

Length of sensor22 mm

Height of sensor25 mm

Width of sensor106.3 mm

Ensured switch distance OFF Sar20 mm

Switch distance12 mm

Hysteresis (Switch distance), maximum2 mm

Repeat accuracy R R0.5 mm

MountingA screw length of 25 mm is s...

Actuating panelslateral

Number of semi-conductor outputs with signaling function1

Number of LEDs3

CascadableYes

Integral System Diagnostics, statusYes

Duration of risk, maximum200 ms

Safety functionsYes

Time to readiness, maximum2,000 ms

Reaction time, maximum100 ms

Short circuit detectionYes

Enclosure materialPlastic, glass-fibre reinfor...

Sensor topologySensor for series wiring

Active principleRFID

StandardsIEC 60947-5-3

Installation conditions (mechanical)not flush

Coding level according to ISO 14119Low

general informationUniversal coding

Housing construction formBlock

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Electrical connectors, which are crucial components for connecting circuit subsections, enable easy disconnection when required. They are typically used for power inputs, peripheral connections, and interchangeable boards.

Electrical Connectors

Recently viewed products

Relevant products

FAQ

5 in stock

M8 female connector, front mounting SMD with M10 screw fastening

Similar products from: Electrical Connectors

What can I help you find today?

Recommended parts