Product description

162815 Euchner - Non-contact safety switches CES-I-BP-.-C07, M12

Product Details

  • Weight
    0.110231 lb
  • Series
    CES-I-BP
  • Product Class
    Safety System
  • Assured operating distance Sao
    min.3 mm
  • Assured release distance Sar
    max.17 mm
  • Switching hysteresis
    min.1 mm
  • Operating distance
    13 mm
  • Mission time
    20 y
  • PFHD
    6 x 10E⁻10
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Category
    4
  • Additional feature
    Caps included
  • Repeat accuracy R
    ≤ 10
  • Off-state current Ir
    max.0,25 mA
  • Test-pulse interval
    ca 100 ms
  • Discrepancy time
    max.10 ms
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Output voltage
    UB-1,5 ... UB V DC
  • Switching current
    1 ... 50 mA
  • Test pulses
    0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Type of output
    p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.125 ms
  • Safety class
    III
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Turn-on time
    max.100 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Fusing
    0,25 ... 8 A
  • Rated insulation voltage Ui
    300 V
  • Current consumption
    40 mA
  • Rated conditional short-circuit current
    100 A
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
  • Connection
    M12 plug connector, 5-pin
  • Switching frequency
    max.1 Hz
  • Reaction time
    6,7 ms
  • Ready delay
    5 s
  • Tightening torque
    max.0,8 Nm
  • Dimensions
    40 x 26.5 x 18
  • Housing material
    Plastic, PBT-PC-GF30
  • Installation orientation
    Any
  • Weight
    0,03 kg
  • Mounting distance
    min.50 mm
  • Mounting method
    Surface mounting on metal
  • Ambient temperature
    -25 ... +55 °C
  • Degree of protection
    IP65/IP67/IP69/IP69K
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Operating altitude
    max.4 000 m

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 162815 on MQ Automation is $234.34. Order now.


About the product

Safety switch with integrated evaluation electronics;Suitable for separate operation (no series connection);Unicode;M12 plug connector, 5-pin (pin 5 not used);Direct connection to IP67 field modules;2 safety outputs (semiconductor outputs);Short circuit monitoring;Category 4 / PL e according to EN ISO 13849-1;Three active faces


This item can ship in 3-5 days!

Manufacturer warranty

162815 Euchner

$234.34

Your price can be lower.
Log in or Create account to check your discount

Stock:

9

Select Qty:

$234.34

$234.34 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 162815 with other products

Weight

Series

Product Class

Assured operating distanc...

Assured release distance ...

Switching hysteresis

Operating distance

Mission time

PFHD

Performance Level

For the approval acc. to ...

Category

Additional feature

Repeat accuracy R

Off-state current Ir

Test-pulse interval

Discrepancy time

Utilization category acc....

Output voltage

Switching current

Test pulses

Type of output

Risk time according to EN...

Safety class

EMC protection requiremen...

Turn-on time

Rated impulse withstand v...

Degree of contamination (...

Fusing

Rated insulation voltage ...

Current consumption

Rated conditional short-c...

Operating voltage DC

Connection

Switching frequency

Reaction time

Ready delay

Tightening torque

Dimensions

Housing material

Installation orientation

Mounting distance

Mounting method

Ambient temperature

Degree of protection

Shock and vibration resis...

Operating altitude

Extension of risk time ac...

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Material

Static bending radius

Selected product

162815
9 in stock
162815
Euchner

162815 Euchner - Non-contact safety switches CES-I-BP-.-C07, M12

Weight0.110231 lb

SeriesCES-I-BP

Product ClassSafety System

Assured operating distance Saomin.3 mm

Assured release distance Sarmax.17 mm

Switching hysteresismin.1 mm

Operating distance13 mm

Mission time20 y

PFHD6 x 10E⁻10

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Additional featureCaps included

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Test-pulse intervalca 100 ms

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Output voltageUB-1,5 ... UB V DC

Switching current1 ... 50 mA

Test pulses0,3 ms (Applies for a load...

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.125 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Turn-on timemax.100 ms

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Fusing0,25 ... 8 A

Rated insulation voltage Ui300 V

Current consumption40 mA

Rated conditional short-circuit current100 A

Operating voltage DC24 V DC 15% ... 15% Regu...

ConnectionM12 plug connector, 5-pin

Switching frequencymax.1 Hz

Reaction time6,7 ms

Ready delay5 s

Tightening torquemax.0,8 Nm

Dimensions40 x 26.5 x 18

Housing materialPlastic, PBT-PC-GF30

Installation orientationAny

Mounting distancemin.50 mm

Mounting methodSurface mounting on metal

Ambient temperature-25 ... +55 °C

Degree of protectionIP65/IP67/IP69/IP69K

Shock and vibration resistanceIn acc. with EN 60947-5-3

Operating altitudemax.4 000 m

Extension of risk time according to EN 60947-5-3 per device-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Assured release distance Sarmax.60 mm

Switching hysteresismin.1 mm

Operating distance11 mm

Mission time20

PFHD4.1 x 10⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Additional featureRubber support included

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Test-pulse intervalmin.140 ms

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Test pulsesmax.1,0 ms (Applies for a l...

Type of outputSemiconductor output, p-swit...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Turn-on timemax.400 ms

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Fusing0,25 ... 8 A

Rated insulation voltage Ui300 V

Current consumptionmax.35 mA (Without taking i...

Rated conditional short-circuit current100 A

Operating voltage DC24 V DC 15% ... 15% Regu...

ConnectionConnection cable PUR, length...

Switching frequencymax.1 Hz

Reaction time-

Ready delay10 s

Tightening torquemax.0,8 Nm

Dimensions-

Housing materialPlastic, PBT

Installation orientationAny

Mounting distancemin.80 mm

Mounting methodSurface mounting on metal

Ambient temperature-

Degree of protectionIP67

Shock and vibration resistanceIn acc. with EN 60947-5-3

Operating altitude-

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Switching hysteresismin.1 mm

Operating distance19 mm

Mission time20

PFHD1.8 x 10⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

Additional feature-

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Test-pulse intervalmin.100 ms

Discrepancy timemax.10 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Test pulsesmax.0,3 ms (Applies for a l...

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Turn-on timemax.300 ms

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Fusing0,25 ... 8 A

Rated insulation voltage Ui75 V

Current consumptionmax.30 mA (Without taking i...

Rated conditional short-circuit current100 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Connectionconnection cable PVC, length...

Switching frequencymax.1 Hz

Reaction time-

Ready delay0,5 s

Tightening torquemax.1 Nm

Dimensions-

Housing materialPlastic, PBT

Installation orientationAny

Mounting distancemin.400 mm

Mounting methodSurface mounting on metal

Ambient temperature-

Degree of protectionIP67, IP69K

Shock and vibration resistanceIn acc. with EN 60947-5-3

Operating altitude-

Extension of risk time according to EN 60947-5-3 per device-

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

Dynamic bending radius10 x cable diameter

Material-

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 162815?
The price of 162815 on MQ Automation is $234.34. Order now.

Out if stock but available for backorder.

162815 Euchner - Non-contact safety switches CES-I-BP-.-C07, M12

What can I help you find today?

Recommended parts