162592 Euchner Safety Proximity Sensors

162592 on MQ Automation
Euchner
  • 162592
  • 162592
  • 162592

Part#:162592

Alt. Part#:CES-I-AP-M-C04-USI-162592

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

162592 Euchner - Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used

Product Details

  • Weight
    0.3086468 lb
  • Series
    CES-AP
  • Product Class
    Safety System
  • Assured operating distance Sao
    min.14 mm
  • Switching hysteresis
    min.1 mm
  • Assured release distance Sar
    max.60 mm
  • Mission time
    20
  • Operating distance
    15 mm
  • Performance Level
    PL e
  • PFHD
    4.1 x 10⁻⁹
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Repeat accuracy R
    ≤ 10
  • Additional feature
    Rubber support included
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Rated conditional short-circuit current
    100 A
  • Output voltage
    UB-1,5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Switching current
    1 ... 150 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Safety class
    III
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Turn-on time
    max.300 ms
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Rated insulation voltage Ui
    300 V
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Ready delay
    0,5 s
  • Current consumption
    max.35 mA
  • Switching frequency
    max.1 Hz
  • Connection
    PUR cable 2000mm with plug connector M12x1, 5-pin, pin 5 not used
  • Fusing
    0,25 ... 8 A
  • Tightening torque
    max.0,8 Nm
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the outputs.)
  • Installation orientation
    Any
  • Housing material
    Plastic, PBT
  • Degree of protection
    IP67
  • Static bending radius
    5 x cable diameter
  • Weight
    0,05 kg
  • Cable ambient temperature (dynamic)
    -25 ... 65 °C
  • Material
    NBR 80 ±5 Shore
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Mounting distance
    min.80 mm
  • Mounting method
    Surface mounting on metal
  • Dynamic bending radius
    10 x cable diameter
  • Cable ambient temperature (static)
    -25 ... 65 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 162592 on MQ Automation is $183.08. Order now.


About the product

Safety switch with integrated evaluation electronics;No series connection;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;Three active faces;Connecting cable PUR, 2 m, plug connector M12, 5-pin; pin 5 not used;Multicode


Manufacturer warranty

162592 Euchner

$183.08

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$183.08

$183.08 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 162592 with other products

Weight

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Mission time

Operating distance

Performance Level

PFHD

Category

For the approval acc. to ...

Repeat accuracy R

Additional feature

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Output voltage

Utilization category acc....

Switching current

Type of output

Test-pulse interval

Test pulses

Safety class

Risk time according to EN...

Degree of contamination (...

Turn-on time

EMC protection requiremen...

Rated insulation voltage ...

Rated impulse withstand v...

Ready delay

Current consumption

Switching frequency

Connection

Fusing

Tightening torque

Operating voltage DC

Installation orientation

Housing material

Degree of protection

Static bending radius

Cable ambient temperature...

Material

Shock and vibration resis...

Mounting distance

Mounting method

Dynamic bending radius

Cable ambient temperature...

Extension of risk time ac...

Selected product

162592
0 in stock
162592
Euchner

162592 Euchner - Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used

Weight0.3086468 lb

SeriesCES-AP

Product ClassSafety System

Assured operating distance Saomin.14 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Mission time20

Operating distance15 mm

Performance LevelPL e

PFHD4.1 x 10⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Additional featureRubber support included

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Output voltageUB-1,5V ... UB V DC (Values...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Switching current1 ... 150 mA

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Degree of contamination (external, according to EN 60947-1)3

Turn-on timemax.300 ms

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Ready delay0,5 s

Current consumptionmax.35 mA

Switching frequencymax.1 Hz

ConnectionPUR cable 2000mm with plug c...

Fusing0,25 ... 8 A

Tightening torquemax.0,8 Nm

Operating voltage DC24 V DC 15% ... 15% Regu...

Installation orientationAny

Housing materialPlastic, PBT

Degree of protectionIP67

Static bending radius5 x cable diameter

Cable ambient temperature (dynamic)-25 ... 65 °C

MaterialNBR 80 ±5 Shore

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Mounting methodSurface mounting on metal

Dynamic bending radius10 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Extension of risk time according to EN 60947-5-3 per device-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Mission time20

Operating distance11 mm

Performance LevelPL e

PFHD4.1 x 10⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Additional featureRubber support included

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Output voltage0,8 x UB ... UB V DC

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching currentmax.50 mA

Type of outputSemiconductor output, p-swit...

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Degree of contamination (external, according to EN 60947-1)3

Turn-on timemax.400 ms

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui300 V

Rated impulse withstand voltage Uimp1,5 kV

Ready delay10 s

Current consumptionmax.35 mA (Without taking i...

Switching frequencymax.1 Hz

ConnectionConnection cable PUR, length...

Fusing0,25 ... 8 A

Tightening torquemax.0,8 Nm

Operating voltage DC24 V DC 15% ... 15% Regu...

Installation orientationAny

Housing materialPlastic, PBT

Degree of protectionIP67

Static bending radius5 x cable diameter

Cable ambient temperature (dynamic)-25 ... 65 °C

MaterialNBR 80 ±5 Shore

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Mounting methodSurface mounting on metal

Dynamic bending radius10 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Assured operating distance Saomin.14 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Mission time20

Operating distance19 mm

Performance LevelPL e

PFHD1.8 x 10⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Additional feature-

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Output voltage0,8 x UB ... UB V DC

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Degree of contamination (external, according to EN 60947-1)3

Turn-on timemax.300 ms

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp1,5 kV

Ready delay0,5 s

Current consumptionmax.30 mA (Without taking i...

Switching frequencymax.1 Hz

Connectionconnection cable PVC, length...

Fusing0,25 ... 8 A

Tightening torquemax.1 Nm

Operating voltage DC24 V DC 15% ... 15% Regu...

Installation orientationAny

Housing materialPlastic, PBT

Degree of protectionIP67, IP69K

Static bending radius5 x cable diameter

Cable ambient temperature (dynamic)0 ... 65 °C

Material-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.400 mm

Mounting methodSurface mounting on metal

Dynamic bending radius10 x cable diameter

Cable ambient temperature (static)-40 ... 65 °C

Extension of risk time according to EN 60947-5-3 per device-

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 162592?
The price of 162592 on MQ Automation is $183.08. Order now.

Out if stock but available for backorder.

162592 Euchner - Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used

What can I help you find today?

Recommended parts