160080 Euchner Safety Proximity Sensors

160080 on MQ Automation
Euchner
  • 160080
  • 160080
  • 160080

Part#:160080

Alt. Part#:CES-I-BP-U-C07-SB-160080

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Only 5 left in stock. Order Now!

Mar 15, 2025

Product description

160080 Euchner - Non-contact safety switches CES-I-BP-.-C07, M12

Product Details

  • Weight
    0.110231 lb
  • Series
    CES-I-BP
  • Product Class
    Safety System
  • Switching hysteresis
    min.1 mm
  • Assured operating distance Sao
    min.10 mm
  • Operating distance
    13 mm
  • Performance Level
    PL e
  • Assured release distance Sar
    max.17 mm
  • Mission time
    20 y
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Category
    4
  • PFHD
    6 x 10E⁻10
  • Additional feature
    Caps included
  • Repeat accuracy R
    ≤ 10
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Test-pulse interval
    ca 100 ms
  • Output voltage
    UB-1,5 ... UB V DC
  • Test pulses
    0,3 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Turn-on time
    max.100 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Switching current
    1 ... 50 mA
  • Type of output
    p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.125 ms
  • Safety class
    III
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Fusing
    0,25 ... 8 A
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    300 V
  • Switching frequency
    max.1 Hz
  • Tightening torque
    max.0,8 Nm
  • Current consumption
    40 mA
  • Rated conditional short-circuit current
    100 A
  • Ready delay
    5 s
  • Installation orientation
    Any
  • Operating voltage DC
    24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
  • Connection
    M12 plug connector, 5-pin
  • Reaction time
    6,7 ms
  • Mounting distance
    min.50 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Dimensions
    40 x 26.5 x 18
  • Weight
    0,03 kg
  • Housing material
    Plastic, PBT-PC-GF30
  • Operating altitude
    max.4 000 m
  • Ambient temperature
    -25 ... +55 °C
  • Mounting method
    Surface mounting on metal
  • Degree of protection
    IP65/IP67/IP69/IP69K

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 160080 on MQ Automation is $236.51. Order now.


About the product

Safety switch with integrated evaluation electronics;Suitable for separate operation (no series connection);Unicode;M12 plug connector, 5-pin;With door monitoring output OD;Diagnostics via IO-Link with safety module ESM-CB;2 safety outputs (semiconductor outputs);Short circuit monitoring;Category 4 / PL e according to EN ISO 13849-1;Three active faces


This item can ship in 3-5 days!

Manufacturer warranty

160080 Euchner

$236.51

Your price can be lower.
Log in or Create account to check your discount

Stock:

5

Select Qty:

$236.51

$236.51 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 160080 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Operating distance

Performance Level

Assured release distance ...

Mission time

For the approval acc. to ...

Category

PFHD

Additional feature

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc....

Test-pulse interval

Output voltage

Test pulses

Turn-on time

Degree of contamination (...

Switching current

Type of output

Risk time according to EN...

Safety class

EMC protection requiremen...

Fusing

Rated impulse withstand v...

Rated insulation voltage ...

Switching frequency

Tightening torque

Current consumption

Rated conditional short-c...

Ready delay

Installation orientation

Operating voltage DC

Connection

Reaction time

Mounting distance

Shock and vibration resis...

Dimensions

Housing material

Operating altitude

Ambient temperature

Mounting method

Degree of protection

Extension of risk time ac...

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Material

Static bending radius

Selected product

160080
5 in stock
160080
Euchner

160080 Euchner - Non-contact safety switches CES-I-BP-.-C07, M12

Weight0.110231 lb

SeriesCES-I-BP

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.10 mm

Operating distance13 mm

Performance LevelPL e

Assured release distance Sarmax.17 mm

Mission time20 y

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

PFHD6 x 10E⁻10

Additional featureCaps included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalca 100 ms

Output voltageUB-1,5 ... UB V DC

Test pulses0,3 ms (Applies for a load...

Turn-on timemax.100 ms

Degree of contamination (external, according to EN 60947-1)3

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.125 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Switching frequencymax.1 Hz

Tightening torquemax.0,8 Nm

Current consumption40 mA

Rated conditional short-circuit current100 A

Ready delay5 s

Installation orientationAny

Operating voltage DC24 V DC 15% ... 15% Regu...

ConnectionM12 plug connector, 5-pin

Reaction time6,7 ms

Mounting distancemin.50 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Dimensions40 x 26.5 x 18

Housing materialPlastic, PBT-PC-GF30

Operating altitudemax.4 000 m

Ambient temperature-25 ... +55 °C

Mounting methodSurface mounting on metal

Degree of protectionIP65/IP67/IP69/IP69K

Extension of risk time according to EN 60947-5-3 per device-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Sao6

Operating distance11 mm

Performance LevelPL e

Assured release distance Sarmax.60 mm

Mission time20

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

PFHD4.1 x 10⁻⁹

Additional featureRubber support included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Test pulsesmax.1,0 ms (Applies for a l...

Turn-on timemax.400 ms

Degree of contamination (external, according to EN 60947-1)3

Switching currentmax.50 mA

Type of outputSemiconductor output, p-swit...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Switching frequencymax.1 Hz

Tightening torquemax.0,8 Nm

Current consumptionmax.35 mA (Without taking i...

Rated conditional short-circuit current100 A

Ready delay10 s

Installation orientationAny

Operating voltage DC24 V DC 15% ... 15% Regu...

ConnectionConnection cable PUR, length...

Reaction time-

Mounting distancemin.80 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Dimensions-

Housing materialPlastic, PBT

Operating altitude-

Ambient temperature-

Mounting methodSurface mounting on metal

Degree of protectionIP67

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Operating distance19 mm

Performance LevelPL e

Assured release distance Sarmax.60 mm

Mission time20

For the approval acc. to UL the following appliesOperation only with UL class...

Category4

PFHD1.8 x 10⁻⁹

Additional feature-

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test-pulse intervalmin.100 ms

Output voltage0,8 x UB ... UB V DC

Test pulsesmax.0,3 ms (Applies for a l...

Turn-on timemax.300 ms

Degree of contamination (external, according to EN 60947-1)3

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Switching frequencymax.1 Hz

Tightening torquemax.1 Nm

Current consumptionmax.30 mA (Without taking i...

Rated conditional short-circuit current100 A

Ready delay0,5 s

Installation orientationAny

Operating voltage DC24 V DC 15% ... 15% Regu...

Connectionconnection cable PVC, length...

Reaction time-

Mounting distancemin.400 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Dimensions-

Housing materialPlastic, PBT

Operating altitude-

Ambient temperature-

Mounting methodSurface mounting on metal

Degree of protectionIP67, IP69K

Extension of risk time according to EN 60947-5-3 per device-

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

Dynamic bending radius10 x cable diameter

Material-

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 160080?
The price of 160080 on MQ Automation is $236.51. Order now.

Out if stock but available for backorder.

160080 Euchner - Non-contact safety switches CES-I-BP-.-C07, M12

What can I help you find today?

Recommended parts