159518 Euchner Safety Proximity Sensors

159518 on MQ Automation
Euchner
  • 159518
  • 159518
  • 159518

Part#:159518

Alt. Part#:CMS-R-BZD-05V

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

159518 Euchner - Read heads CMS, design B - with NO contact combinations, PVC

Product Details

  • Weight
    0.58201968 lb
  • Series
    CMS read heads
  • Product Class
    Safety System
  • Assured operating distance Sao
    min.7 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
  • In compliance with
    EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN ISO 14119: 2013; EN 60947-5-3: 2013
  • Center offset
    2,5 mm (Figure only applies if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
  • Assured release distance Sar
    max.20 mm (The assured switch-off distance s_ar corresponds to the reset distance.)
  • B10D
    20 x 10⁶
  • Actuating range On
    min.6 mm (These values apply only in approach direction X, center offset m=0)
  • Switching frequency, electrical
    max.5 Hz (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
  • Actuating range Off
    max.20 mm (These values apply only in approach direction X, center offset m=0)
  • Switching delay from state change
    26 ms (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
  • Switching voltage according to UL
    max.24 V AC/DC
  • Switching characteristics
    Parallel
  • Switching current
    max.100 mA
  • Switching voltage
    max.35 V (DC)
  • Fusing
    Fuse 10 A gG (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
  • Method of operation
    Magnetic, reed contact
  • Rated conditional short-circuit current
    100 A (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
  • Mechanical life
    100 x 10⁶
  • Cable length
    5 m
  • Connection
    Hard-wired encapsulated cable with cable end sleeves 0.25mm²
  • Number of NO contacts
    2 NO contacts with internal fuse 100 mA each, 1 NO contact as monitoring contact
  • Degree of protection
    IP67
  • Housing material
    Fiber glass reinforced PPS
  • Weight
    0,16 kg
  • Material
    PVC
  • Design
    B
  • Tightening torque
    0,4 ... 0,5 Nm
  • Ambient temperature
    -20 ... 80 °C
  • Installation orientation
    Any, pay attention to marking (During mounting it is to be ensured the marking arrows on actuator and read head are opposite each other.)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 159518 on MQ Automation is $82.89. Order now.


About the product

In combination with evaluation units ESM-BA...;Cube-shaped version, 36 x 26 mm;Connecting cable;Cable type: PVC


Manufacturer warranty

159518 Euchner

$82.89

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$82.89

$82.89 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 159518 with other products

Weight

Series

Product Class

Assured operating distanc...

In compliance with

Center offset

Assured release distance ...

B10D

Actuating range On

Switching frequency, elec...

Actuating range Off

Switching delay from stat...

Switching voltage accordi...

Switching characteristics

Switching current

Switching voltage

Fusing

Method of operation

Rated conditional short-c...

Mechanical life

Cable length

Connection

Number of NO contacts

Degree of protection

Housing material

Material

Design

Tightening torque

Ambient temperature

Installation orientation

Degree of contamination (...

Connecting cable

Rated impulse withstand v...

Rated insulation voltage ...

Utilization category acc....

Short circuit protection ...

Switching principle

Number of positively driv...

Switching hysteresis

Operating distance

Mission time

PFHD

For the approval acc. to ...

Additional feature

Performance Level

Repeat accuracy R

Category

Discrepancy time

Off-state current Ir

Test-pulse interval

Utilization category acc....

Test pulses

Output voltage

Type of output

Turn-on time

Risk time according to EN...

Safety class

EMC protection requiremen...

Operating voltage DC

Switching frequency

Extension of risk time ac...

Current consumption

Ready delay

Mounting method

Shock and vibration resis...

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Static bending radius

Selected product

159518
0 in stock
159518
Euchner

159518 Euchner - Read heads CMS, design B - with NO contact combinations, PVC

Weight0.58201968 lb

SeriesCMS read heads

Product ClassSafety System

Assured operating distance Saomin.7 mm (Figure only appli...

In compliance withEN ISO 13849-1: 2015; EN 620...

Center offset2,5 mm (Figure only applies...

Assured release distance Sarmax.20 mm (The assured swit...

B10D20 x 10⁶

Actuating range Onmin.6 mm (These values appl...

Switching frequency, electricalmax.5 Hz (Parameter depende...

Actuating range Offmax.20 mm (These values app...

Switching delay from state change26 ms (Parameter dependent ...

Switching voltage according to ULmax.24 V AC/DC

Switching characteristicsParallel

Switching currentmax.100 mA

Switching voltagemax.35 V (DC)

FusingFuse 10 A gG (Parameter dep...

Method of operationMagnetic, reed contact

Rated conditional short-circuit current100 A (Parameter dependent...

Mechanical life100 x 10⁶

Cable length5 m

ConnectionHard-wired encapsulated cabl...

Number of NO contacts2 NO contacts with internal ...

Degree of protectionIP67

Housing materialFiber glass reinforced PPS

MaterialPVC

DesignB

Tightening torque0,4 ... 0,5 Nm

Ambient temperature-20 ... 80 °C

Installation orientationAny, pay attention to markin...

Degree of contamination (external, according to EN 60947-1)-

Connecting cable-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Utilization category acc. to EN 60947-5-1-

Short circuit protection according to IEC 60269-1-

Switching principle-

Number of positively driven contacts-

Switching hysteresis-

Operating distance-

Mission time-

PFHD-

For the approval acc. to UL the following applies-

Additional feature-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Output voltage-

Type of output-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Operating voltage DC-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Ready delay-

Mounting method-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

070765
1 in stock
070765
Euchner

070765 Euchner - ENABLING SWITCH

Weight2.75625 lb

Series-

Product Class-

Assured operating distance Sao-

In compliance with60947-5-8

Center offset-

Assured release distance Sar-

B10D0,5 x 10⁶

Actuating range On-

Switching frequency, electrical-

Actuating range Off-

Switching delay from state change-

Switching voltage according to UL-

Switching characteristics3-stage enabling switch

Switching current1 mA

Switching voltage12 V

Fusing-

Method of operation-

Rated conditional short-circuit current100 A

Mechanical life0,1 x 10⁶

Cable length10 m

ConnectionFlying lead

Number of NO contacts2

Degree of protectionIP67

Housing material-

MaterialPlastic

Design-

Tightening torque-

Ambient temperature-5 ... 50 °C

Installation orientation-

Degree of contamination (external, according to EN 60947-1)3

Connecting cable8x0.34mm² (4x0.34mm² screen...

Rated impulse withstand voltage Uimp2,5 kV

Rated insulation voltage Ui250 V

Utilization category acc. to EN 60947-5-12A 230V

Short circuit protection according to IEC 60269-12A gG (In case of operating...

Switching principleSlow-action contact element

Number of positively driven contacts2

Switching hysteresis-

Operating distance-

Mission time-

PFHD-

For the approval acc. to UL the following applies-

Additional feature-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Output voltage-

Type of output-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Operating voltage DC-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Ready delay-

Mounting method-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

In compliance with-

Center offset-

Assured release distance Sarmax.60 mm

B10D-

Actuating range On-

Switching frequency, electrical-

Actuating range Off-

Switching delay from state change-

Switching voltage according to UL-

Switching characteristics-

Switching currentmax.50 mA

Switching voltage-

Fusing0,25 ... 8 A

Method of operation-

Rated conditional short-circuit current100 A

Mechanical life-

Cable length-

ConnectionConnection cable PUR, length...

Number of NO contacts-

Degree of protectionIP67

Housing materialPlastic, PBT

MaterialNBR 80 ±5 Shore

Design-

Tightening torquemax.0,8 Nm

Ambient temperature-

Installation orientationAny

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Utilization category acc. to EN 60947-5-1-

Short circuit protection according to IEC 60269-1-

Switching principle-

Number of positively driven contacts-

Switching hysteresismin.1 mm

Operating distance11 mm

Mission time20

PFHD4.1 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Performance LevelPL e

Repeat accuracy R≤ 10

Category4

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-swit...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.35 mA (Without taking i...

Ready delay10 s

Mounting methodSurface mounting on metal

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 159518?
The price of 159518 on MQ Automation is $82.89. Order now.

Out if stock but available for backorder.

159518 Euchner - Read heads CMS, design B - with NO contact combinations, PVC

What can I help you find today?

Recommended parts