159112 Euchner Safety Switches

159112 on MQ Automation
Euchner
  • 159112
  • 159112

Part#:159112

Alt. Part#:CTP-L2-AR-U-HA-AEE-SH-159112

Manufacturer:Euchner

Category:Safety Switches

Product Lifecycle:Active

Product description

159112 Euchner - Transponder-coded safety switch CTP-AR, M23, emergency stop, 2 pushbuttons (extended), with escape release

Product Details

  • Weight
    1.763696 lb
  • Series
    CTP-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • Performance Level
    PL e
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • B10D
    0,13 x 10⁶
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    2 pos. driven NC
  • PFHD
    4.1 x 10 ⁻⁹
  • Version
    Emergency stop
  • Power supply
    24 V
  • Operating voltage
    UB V
  • Operating current
    1 ... 50 mA
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Turn-on time
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching current
    1 ... 150 mA
  • Output voltage
    0 ... 1 V DC
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Safety class
    III
  • Solenoid duty cycle
    100 %
  • Fusing
    0,25 ... 8 A
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    6 W
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    50 V
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Current consumption
    40 mA
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Overtravel
    5 mm
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Actuating force
    10 N
  • Extraction force
    20 N
  • Test-pulse interval
    min.140 ms
  • Retention force
    20 N
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Locking force Fmax
    3900 N
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Switching frequency
    max.0,5 Hz
  • Connection
    1 plug connector M23, 19-pin, RC18
  • Degree of protection
    IP65 (Screwed tight plug connector/mating component)
  • Installation orientation
    Any
  • Weight
    0,57 kg
  • Mechanical life
    1 x 10⁶
  • Ready delay
    8 s
  • Ambient temperature
    -20 ... +55 °C
  • Housing material
    Die-cast zinc
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 159112 on MQ Automation is $1,318.33. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;Emergency stop;2 pushbuttons (illuminated);With plug connector M23;Unicode;Door monitoring output;With escape release;Approach directions A, B and C (delivery state)


Manufacturer warranty

159112 Euchner

$1,318.33

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,318.33

$1,318.33 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 159112 with other products

Weight

Series

Product Class

Mission time

Performance Level

Category

For the approval acc. to ...

B10D

Additional feature

Switching element

PFHD

Version

Power supply

Operating voltage

Operating current

Repeat accuracy R

Discrepancy time

Turn-on time

Off-state current Ir

Type of output

Switching current

Output voltage

Switching load

Degree of contamination (...

Risk time according to EN...

Safety class

Solenoid duty cycle

Fusing

EMC protection requiremen...

Connection rating

Rated impulse withstand v...

Rated insulation voltage ...

Solenoid operating voltag...

Utilization category acc....

Current consumption

Test pulses

Overtravel

Operating voltage DC

Actuating force

Extraction force

Test-pulse interval

Retention force

Locking force FZh

Locking force Fmax

Guard locking principle

Approach speed

Switching frequency

Connection

Degree of protection

Installation orientation

Mechanical life

Ready delay

Ambient temperature

Housing material

Shock and vibration resis...

Extension of risk time ac...

Detent mechanism

Selected product

159112
0 in stock
159112
Euchner

159112 Euchner - Transponder-coded safety switch CTP-AR, M23, emergency stop, 2 pushbuttons (extende...

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

B10D0,13 x 10⁶

Additional featureIncl. cover set ID. No. 1203...

Switching element2 pos. driven NC

PFHD4.1 x 10 ⁻⁹

VersionEmergency stop

Power supply24 V

Operating voltageUB V

Operating current1 ... 50 mA

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Solenoid duty cycle100 %

Fusing0,25 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Test pulsesmax.1,0 ms (Applies for a l...

Overtravel5 mm

Operating voltage DC24 V DC -15% ... 15% Rev...

Actuating force10 N

Extraction force20 N

Test-pulse intervalmin.140 ms

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleOpen-circuit current princip...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection1 plug connector M23, 19-pin...

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationAny

Mechanical life1 x 10⁶

Ready delay8 s

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Shock and vibration resistanceIn acc. with EN 60947-5-3

Extension of risk time according to EN 60947-5-3 per device-

Detent mechanism-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

B10D-

Additional featureEscape release actuated by p...

Switching element-

PFHD4.1 x 10 ⁻⁹

Version-

Power supply-

Operating voltage-

Operating current-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Type of outputp-switching, short circuit-p...

Switching current1 ... 50 mA

Output voltage0,8xUB ... UB V DC

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Solenoid duty cycle100 %

Fusing0,25 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Test pulsesmax.1,0 ms (Applies for a l...

Overtravel5 mm

Operating voltage DC24 V DC -15% ... 15% Rev...

Actuating force10 N

Extraction force20 N

Test-pulse intervalmin.140 ms

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Mechanical life1 x 10⁶

Ready delay8 s

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Shock and vibration resistanceIn acc. with EN 60947-5-3

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Detent mechanism-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

B10D0,13 x 10⁶

Additional feature-

Switching element2 pos. driven NC

PFHD4.1 x 10 ⁻⁹

VersionEmergency stop

Power supply-

Operating voltage5 ... 24 V

Operating current1 ... 100 mA

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Risk time according to EN 60947-5-3-

Safety classIII

Solenoid duty cycle-

Fusing0,25 ... 8 A

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Test pulsesmax.0,3 ms (Applies for a l...

Overtravel5 mm

Operating voltage DC24 V DC -15% ... 15% Rev...

Actuating force10 N

Extraction force20 N

Test-pulse intervalmin.100 ms

Retention force-

Locking force FZh-

Locking force Fmax-

Guard locking principle-

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Ready delaymax.1 s

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Extension of risk time according to EN 60947-5-3 per device-

Detent mechanismSnap-in bolt

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 159112?
The price of 159112 on MQ Automation is $1,318.33. Order now.

Out if stock but available for backorder.

159112 Euchner - Transponder-coded safety switch CTP-AR, M23, emergency stop, 2 pushbuttons (extended), with escape release

Similar products from: Safety Switches

What can I help you find today?

Recommended parts