159090 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 4 control elements, emergency release, 7/8" and M12 plugs

Product Details

  • Weight
    8.267325 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20
  • Category
    4
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Diagnostic Coverage (DC)
    99
  • B10D
    0,13 x 10⁶
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Additional feature
    Incl. cover set ID. No. 120344
  • Product version number
    V3.30.10
  • Performance Level
    PL e
  • Switching element
    2 pos. driven NC
  • Version
    Emergency stop illuminated
  • Assignment diagram
    B1
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Transponder coding
    Unicode
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Rated insulation voltage Ui
    75 V
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Safety class
    III
  • Current consumption
    max.500 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Locking force FZh
    2000 N
  • Installation orientation
    Door hinge DIN right
  • Guard locking principle
    Closed-circuit current principle
  • Degree of protection
    IP54
  • Connection
    7/8" Power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Ambient temperature
    -20 ... 55 °C
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Weight
    3,1 kg
  • Switching frequency
    0,25 Hz
  • Mechanical life
    0,1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 159090 on MQ Automation is $3,249.64. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;4 illuminated pushbuttons;including adhesive labels;Connection via 7/8&quot; and M12 plugs;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

159090 Euchner

$3,249.64

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,249.64

$3,249.64 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 159090 with other products

Weight

Series

Product Class

Mission time

Category

PFHD

Diagnostic Coverage (DC)

B10D

Safety Integrity Level

Additional feature

Product version number

Performance Level

Switching element

Version

Assignment diagram

Bus data protocol

Assured release distance ...

Safety data protocol

Transponder coding

Fusing

Auxiliary voltage DC

Operating voltage DC

Rated insulation voltage ...

Connecting cable

EMC protection requiremen...

Safety class

Current consumption

Rated impulse withstand v...

Housing material

Degree of contamination (...

Maximum feed-in current i...

Locking force FZh

Installation orientation

Guard locking principle

Degree of protection

Connection

Ambient temperature

Reaction time

Switching frequency

Mechanical life

Shock and vibration resis...

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

159090
0 in stock
159090
Euchner

159090 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) wi...

Weight8.267325 lb

SeriesSpare parts

Product ClassAccessories

Mission time20

Category4

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Diagnostic Coverage (DC)99

B10D0,13 x 10⁶

Safety Integrity LevelSIL 3 (EN 62061:2005)

Additional featureIncl. cover set ID. No. 1203...

Product version numberV3.30.10

Performance LevelPL e

Switching element2 pos. driven NC

VersionEmergency stop illuminated

Assignment diagramB1

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Safety data protocolProfisafe (IEC 61784-3-3)

Transponder codingUnicode

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Rated insulation voltage Ui75 V

Connecting cableProfinet I/O cable, at least...

EMC protection requirementsIn accordance with EN 61000-...

Safety classIII

Current consumptionmax.500 mA

Rated impulse withstand voltage Uimp0,5 kV

Housing materialReinforced plastic, die-cast...

Degree of contamination (external, according to EN 60947-1)3

Maximum feed-in current in the connection blockmax.4000 mA

Locking force FZh2000 N

Installation orientationDoor hinge DIN right

Guard locking principleClosed-circuit current princ...

Degree of protectionIP54

Connection7/8" Power (X1 (The documen...

Ambient temperature-20 ... 55 °C

Reaction timemax.250 ms Switch-off time...

Switching frequency0,25 Hz

Mechanical life0,1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Diagnostic Coverage (DC)-

B10D0,13 x 10⁶

Safety Integrity Level-

Additional feature-

Product version number-

Performance LevelPL e

Switching element2 pos. driven NC

VersionEmergency stop

Assignment diagram-

Bus data protocol-

Assured release distance Sar-

Safety data protocol-

Transponder coding-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Rated insulation voltage Ui50 V

Connecting cable-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Safety classIII

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Housing materialFiber glass reinforced therm...

Degree of contamination (external, according to EN 60947-1)3

Maximum feed-in current in the connection block-

Locking force FZh-

Installation orientationDoor hinge DIN right

Guard locking principle-

Degree of protectionIP65 (Screwed tight plug co...

Connection2 plug connectors M12, 5-pin

Ambient temperature-20 ... +55 °C

Reaction time-

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Category4

PFHD4.1 x 10 ⁻⁹

Diagnostic Coverage (DC)-

B10D-

Safety Integrity Level-

Additional featureEscape release actuated by p...

Product version number-

Performance LevelPL e

Switching element-

Version-

Assignment diagram-

Bus data protocol-

Assured release distance Sar-

Safety data protocol-

Transponder coding-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Rated insulation voltage Ui50 V

Connecting cable-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Safety classIII

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

Housing materialDie-cast zinc

Degree of contamination (external, according to EN 60947-1)3

Maximum feed-in current in the connection block-

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Installation orientationAny

Guard locking principleClosed-circuit current princ...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Connection2 plug connectors M12, 5 and...

Ambient temperature-20 ... +55 °C

Reaction time-

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 159090?
The price of 159090 on MQ Automation is $3,249.64. Order now.

Out if stock but available for backorder.

159090 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 4 control elements, emergency release, 7/8&quot; and M12 plugs

What can I help you find today?

Recommended parts