158875 Euchner Safety Relays

158875 on MQ Automation
Euchner
  • 158875
  • 158875
  • 158875

Part#:158875

Alt. Part#:ESM-CB-AZ-FI2-BR-IO-158875

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

7 in stock

Mar 15, 2025

Product description

158875 Euchner - IO-Link Gateway with relay outputs for BP/BR switches

Product Details

  • Weight
    0.50926722 lb
  • Series
    ESM
  • Product Class
    Gateway
  • SIL CL
    3
  • PFHD
    1.00 x 10⁻⁹ (This value is dependent on the number of switching cycles and the switching current.)
  • Mission time
    20 y (This value is dependent on the number of switching cycles and the switching current.)
  • Performance Level
    PL e (4 A DC13; 5 A AC15; 8,760 operating cycles/year) (A demand rate of the safety function of once per month is required for applications in PL e.)
  • Category
    4
  • Proof-test interval
    240 Monate
  • ESPE type
    Type A
  • PFD
    3.76 x 10⁻⁵ (This value is dependent on the number of switching cycles and the switching current.)
  • Data rate
    230 kbit/s
  • Product version number
    Version 1.1
  • Description
    NPN (S12), NPN/PNP (S22)
  • Operating voltage DC
    24 V DC -20% ... +25% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
  • Demand rate
    < 12 Monate
  • Discrepancy time
  • Cycle time
    5 ms
  • Input voltage
    11 ... 30 V DC
  • Input current
    0 ... 2 mA
  • Process-data update
    5 ms
  • Test-pulse interval
    Test-pulse rate = 5 x test-pulse width (Deactivate switch-on pulses/light tests on safety applications.)
  • Test pulses
    1,5 ms ((test-pulse width, LOW test pulses))
  • Current consumption
    16 mA
  • Reverse polarity protection
    Serial reverse polarity protection
  • Power supply
    24 24 V DC -20% / +25% (provided via the IO-Link interface of the IO-Link master)
  • Breaking capacity
    min.0,06 W
  • Output voltage
    22 V DC (Us - 2 V)
  • Short-circuit current
    4A (24 V (DC13)), 5A (250 V (AC15))
  • Switching current
    max.6000 mA
  • Fusing
    6A gG
  • Cumulative current
    max.10,5 A For all contacts
  • Type of output
    Two NO contacts in series, non-time-delayed, floating, positively driven (redundant) (Positively-driven relay according to IEC/EN 61810-3 (EN 50205))
  • Switching voltage
    12 ... 250 V
  • LED indicator
    1x operating voltage display PWR, 5x status displays DIA, STATE1, STATE2, K1/K2, IO-Link
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Connection cross-section
    0,2 ... 1,5 mm²
  • Connection rating
    1,44 W
  • Overvoltage category according to IEC EN 60664-1
    2
  • Rated insulation voltage Ui
    320 V
  • Connection type
    3-conductor
  • Rated impulse withstand voltage Uimp
    4 kV
  • Number of inputs
    1
  • Power dissipation
    max.6,45 W ((US=30 V, UL=30 V, I²=72 A²))
  • Mechanical life
    10 x 10⁶
  • Number of masters
    1
  • Switching frequency
    0,5 Hz
  • Number of monitoring outputs
    1
  • Contact material
    AgSnO2
  • Installation orientation
    vertical or horizontal
  • Number of safety contacts
    2
  • Stripping length
    8 mm
  • Connection
    plug-in spring terminals
  • Housing material
    PBT, gray
  • Dimensions
    17.5 x 116.5 x 114.5
  • Mounting method
    Mounting rail 35mm according to DIN EN 60715 TH35
  • permissible shock and vibration load
    10 Hz...150 Hz, 2 g
  • Atmospheric humidity
    max.75 % rH
  • Ambient temperature
    -25 ... 60 °C
  • Degree of protection
    IP20
  • Weight
    0,148 kg
  • Type specification
    Electromechanical relay with positively driven contacts according to IEC/EN 61810-3 (EN 50205)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 158875 on MQ Automation is $474.36. Order now.


About the product

IO-Link device for reading process and device data of BP/BR safety switches and transferring them to a higher-level control system;Control of guard locking of BP/BR switches, depending on the switch used;Compact version measuring only 18 mm in width;Rail mounting;LED status indicators;Sensor circuit 1: connection of single- or dual-channel safety switches with floating contacts; short circuit, earth fault and ground fault detection;Sensor circuit 2: connection of 2 safety outputs for BP/BR switches;Use as safety relay with two safe outputs;Start button and feedback loop can be connected;Safety relay: use up to category 4 according to EN ISO 13849-1


This item can ship in 3-5 days!

Manufacturer warranty

158875 Euchner

$474.36

Your price can be lower.
Log in or Create account to check your discount

Stock:

7

Select Qty:

$474.36

$474.36 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 158875 with other products

Weight

Series

Product Class

SIL CL

PFHD

Mission time

Performance Level

Category

Proof-test interval

ESPE type

PFD

Data rate

Product version number

Description

Operating voltage DC

Demand rate

Discrepancy time

Cycle time

Input voltage

Input current

Process-data update

Test-pulse interval

Test pulses

Current consumption

Reverse polarity protecti...

Power supply

Breaking capacity

Output voltage

Short-circuit current

Switching current

Fusing

Cumulative current

Type of output

Switching voltage

LED indicator

Degree of contamination (...

Connection cross-section

Connection rating

Overvoltage category acco...

Rated insulation voltage ...

Connection type

Rated impulse withstand v...

Number of inputs

Power dissipation

Mechanical life

Number of masters

Switching frequency

Number of monitoring outp...

Contact material

Installation orientation

Number of safety contacts

Stripping length

Connection

Housing material

Dimensions

Mounting method

permissible shock and vib...

Atmospheric humidity

Ambient temperature

Degree of protection

Type specification

For the approval acc. to ...

Additional feature

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching load

Risk time according to EN...

Safety class

Solenoid duty cycle

EMC protection requiremen...

Solenoid operating voltag...

Utilization category acc....

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Locking force FZh

Guard locking principle

Ready delay

Shock and vibration resis...

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

158875
7 in stock
158875
Euchner

158875 Euchner - IO-Link Gateway with relay outputs for BP/BR switches

Weight0.50926722 lb

SeriesESM

Product ClassGateway

SIL CL3

PFHD1.00 x 10⁻⁹ (This value is ...

Mission time20 y (This value is depende...

Performance LevelPL e (4 A DC13; 5 A AC15; 8,...

Category4

Proof-test interval240 Monate

ESPE typeType A

PFD3.76 x 10⁻⁵ (This value is ...

Data rate230 kbit/s

Product version numberVersion 1.1

DescriptionNPN (S12), NPN/PNP (S22)

Operating voltage DC24 V DC -20% ... +25% (Al...

Demand rate< 12 Monate

Discrepancy time

Cycle time5 ms

Input voltage11 ... 30 V DC

Input current0 ... 2 mA

Process-data update5 ms

Test-pulse intervalTest-pulse rate = 5 x test-p...

Test pulses1,5 ms ((test-pulse width,...

Current consumption16 mA

Reverse polarity protectionSerial reverse polarity prot...

Power supply24 24 V DC -20% / +25% (...

Breaking capacitymin.0,06 W

Output voltage22 V DC (Us - 2 V)

Short-circuit current4A (24 V (DC13)), 5A (250 V ...

Switching currentmax.6000 mA

Fusing6A gG

Cumulative currentmax.10,5 A For all contact...

Type of outputTwo NO contacts in series, n...

Switching voltage12 ... 250 V

LED indicator1x operating voltage display...

Degree of contamination (external, according to EN 60947-1)2

Connection cross-section0,2 ... 1,5 mm²

Connection rating1,44 W

Overvoltage category according to IEC EN 60664-12

Rated insulation voltage Ui320 V

Connection type3-conductor

Rated impulse withstand voltage Uimp4 kV

Number of inputs1

Power dissipationmax.6,45 W ((US=30 V, UL=30...

Mechanical life10 x 10⁶

Number of masters1

Switching frequency0,5 Hz

Number of monitoring outputs1

Contact materialAgSnO2

Installation orientationvertical or horizontal

Number of safety contacts2

Stripping length8 mm

Connectionplug-in spring terminals

Housing materialPBT, gray

Dimensions17.5 x 116.5 x 114.5

Mounting methodMounting rail 35mm according...

permissible shock and vibration load10 Hz...150 Hz, 2 g

Atmospheric humiditymax.75 % rH

Ambient temperature-25 ... 60 °C

Degree of protectionIP20

Type specificationElectromechanical relay with...

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Solenoid duty cycle-

EMC protection requirements-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Guard locking principle-

Ready delay-

Shock and vibration resistance-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

SIL CL-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Proof-test interval-

ESPE type-

PFD-

Data rate-

Product version number-

Description-

Operating voltage DC24 V DC -15% ... 15% Rev...

Demand rate-

Discrepancy timemax.10 ms In acc. with EN ...

Cycle time-

Input voltage-

Input current-

Process-data update-

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Current consumption40 mA

Reverse polarity protection-

Power supply-

Breaking capacity-

Output voltage0,8xUB ... UB V DC

Short-circuit current-

Switching current1 ... 50 mA

Fusing0,25 ... 8 A

Cumulative current-

Type of outputp-switching, short circuit-p...

Switching voltage-

LED indicator-

Degree of contamination (external, according to EN 60947-1)3

Connection cross-section-

Connection rating6 W

Overvoltage category according to IEC EN 60664-1-

Rated insulation voltage Ui50 V

Connection type-

Rated impulse withstand voltage Uimp0,5 kV

Number of inputs-

Power dissipation-

Mechanical life1 x 10⁶

Number of masters-

Switching frequencymax.0,5 Hz

Number of monitoring outputs-

Contact material-

Installation orientationAny

Number of safety contacts-

Stripping length-

Connection2 plug connectors M12, 5 and...

Housing materialDie-cast zinc

Dimensions-

Mounting method-

permissible shock and vibration load-

Atmospheric humidity-

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Type specification-

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

SIL CL-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Proof-test interval-

ESPE type-

PFD-

Data rate-

Product version number-

Description-

Operating voltage DC24 V DC -15% ... 15% Rev...

Demand rate-

Discrepancy timemax.10 ms In acc. with EN ...

Cycle time-

Input voltage-

Input current-

Process-data update-

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Current consumption40 mA

Reverse polarity protection-

Power supply-

Breaking capacity-

Output voltage0 ... 1 V DC

Short-circuit current-

Switching current1 ... 150 mA

Fusing0,25 ... 8 A

Cumulative current-

Type of output2 semiconductor outputs, p-s...

Switching voltage-

LED indicator-

Degree of contamination (external, according to EN 60947-1)3

Connection cross-section-

Connection rating1 W

Overvoltage category according to IEC EN 60664-1-

Rated insulation voltage Ui50 V

Connection type-

Rated impulse withstand voltage Uimp0,5 kV

Number of inputs-

Power dissipation-

Mechanical life1 x 10⁶

Number of masters-

Switching frequencymax.0,5 Hz

Number of monitoring outputs-

Contact material-

Installation orientationDoor hinge DIN right

Number of safety contacts-

Stripping length-

Connection2 plug connectors M12, 5-pin

Housing materialFiber glass reinforced therm...

Dimensions-

Mounting method-

permissible shock and vibration load-

Atmospheric humidity-

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Type specification-

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3-

Safety classIII

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Locking force FZh-

Guard locking principle-

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 158875?
The price of 158875 on MQ Automation is $474.36. Order now.

Out if stock but available for backorder.

158875 Euchner - IO-Link Gateway with relay outputs for BP/BR switches

What can I help you find today?

Recommended parts