158763 Euchner Safety Proximity Sensors

158763 on MQ Automation
Euchner
  • 158763
  • 158763
  • 158763

Part#:158763

Alt. Part#:CEM-A-LE05K-S2-P-158763

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

158763 Euchner - Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence, permanent magnet

Product Details

  • Weight
    0.96562356 lb
  • Series
    CEM read heads
  • Product Class
    Safety System
  • Center offset
    -2,5 ... +2,5 mm
  • Assured release distance Sar
    max.20 mm (In conjunction with evaluation unit CES-A-...B or CES-AZ-...B)
  • Assured operating distance Sao
    min.2 mm (In conjunction with evaluation unit CES-A-...B or CES-AZ-...B)
  • Solenoid duty cycle
    100 %
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Cable length
    max.25 m
  • Connection rating
    2,5 W
  • Current consumption
    100 mA
  • Locking force F
    650 N
  • Guard locking principle
    Open-circuit current principle
  • Adhesive force
    30 N
  • Switching hysteresis
    0,7 mm (In conjunction with evaluation unit CES-A-...B or CES-AZ-...B)
  • Weight
    0,4 kg
  • Switching frequency
    max.1 Hz
  • Ambient temperature
    -25 ... 50 °C
  • Mechanical life
    1 x 10⁶
  • Degree of protection
    IP67
  • Connection
    Plug connector M8x1, 4-pin male (with snap-action / screw terminal)
  • Installation orientation
    Any
  • Material
    Steel, nickel-plated
  • Housing material
    Die-cast aluminum

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 158763 on MQ Automation is $360.75. Order now.


About the product

Read head with guard locking without guard lock monitoring;Locking force 650 N;With permanent magnet 30 N;Up to category 4 according to EN ISO 13849-1;Two safety screws M5x16 included


Manufacturer warranty

158763 Euchner

$360.75

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$360.75

$360.75 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 158763 with other products

Weight

Series

Product Class

Center offset

Assured release distance ...

Assured operating distanc...

Solenoid duty cycle

Operating voltage DC

Cable length

Connection rating

Current consumption

Locking force F

Guard locking principle

Adhesive force

Switching hysteresis

Switching frequency

Ambient temperature

Mechanical life

Degree of protection

Connection

Installation orientation

Material

Housing material

Mission time

PFHD

Category

Performance Level

For the approval acc. to ...

Additional feature

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN...

Safety class

Degree of contamination (...

EMC protection requiremen...

Rated impulse withstand v...

Rated insulation voltage ...

Fusing

Solenoid operating voltag...

Utilization category acc....

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Locking force FZh

Ready delay

Shock and vibration resis...

B10D

Connection cross-section

Switching voltage

Short circuit protection ...

Solenoid operating voltag...

Thermal rated current Ith

Insertion depth

Utilization category acc....

Actuation frequency

Number of door position N...

Number of guard lock moni...

Number of door position N...

Switching principle

Contact material

Selected product

158763
0 in stock
158763
Euchner

158763 Euchner - Read head CEM-A-LE05... with guard locking without guard lock monitoring with reman...

Weight0.96562356 lb

SeriesCEM read heads

Product ClassSafety System

Center offset-2,5 ... +2,5 mm

Assured release distance Sarmax.20 mm (In conjunction w...

Assured operating distance Saomin.2 mm (In conjunction wi...

Solenoid duty cycle100 %

Operating voltage DC24 V DC -15% ... 10%

Cable lengthmax.25 m

Connection rating2,5 W

Current consumption100 mA

Locking force F650 N

Guard locking principleOpen-circuit current princip...

Adhesive force30 N

Switching hysteresis0,7 mm (In conjunction with...

Switching frequencymax.1 Hz

Ambient temperature-25 ... 50 °C

Mechanical life1 x 10⁶

Degree of protectionIP67

ConnectionPlug connector M8x1, 4-pin m...

Installation orientationAny

MaterialSteel, nickel-plated

Housing materialDie-cast aluminum

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Locking force FZh-

Ready delay-

Shock and vibration resistance-

B10D-

Connection cross-section-

Switching voltage-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Utilization category acc. to EN 60947-5-1-

Actuation frequency-

Number of door position NO contacts-

Number of guard lock monitoring positively driven contacts-

Number of door position NC contacts-

Switching principle-

Contact material-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Center offset-

Assured release distance Sar-

Assured operating distance Sao-

Solenoid duty cycle100 %

Operating voltage DC24 V DC -15% ... 15% Rev...

Cable length-

Connection rating6 W

Current consumption40 mA

Locking force F-

Guard locking principleClosed-circuit current princ...

Adhesive force-

Switching hysteresis-

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Material-

Housing materialDie-cast zinc

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Category4

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Connection cross-section-

Switching voltage-

Short circuit protection according to IEC 60269-1-

Solenoid operating voltage-

Thermal rated current Ith-

Insertion depth-

Utilization category acc. to EN 60947-5-1-

Actuation frequency-

Number of door position NO contacts-

Number of guard lock monitoring positively driven contacts-

Number of door position NC contacts-

Switching principle-

Contact material-

100322
380 in stock
100322
Euchner

100322 Euchner - Safety switch STP with door monitoring contact, escape release

Weight1.24781492 lb

SeriesSTP

Product ClassSafety switch

Center offset-

Assured release distance Sar-

Assured operating distance Sao-

Solenoid duty cycle100 %

Operating voltage DC-

Cable length-

Connection rating8 W

Current consumption-

Locking force F-

Guard locking principleOpen-circuit current princip...

Adhesive force-

Switching hysteresis-

Switching frequency-

Ambient temperature-20 ... 55 °C

Mechanical life1 x 10⁶

Degree of protectionIP67

ConnectionM20 x 1.5

Installation orientationAny

Material-

Housing materialReinforced thermoplastic

Mission time-

PFHD-

Category-

Performance Level-

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current1 mA

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Safety class-

Degree of contamination (external, according to EN 60947-1)-

EMC protection requirements-

Rated impulse withstand voltage Uimp2,5 kV

Rated insulation voltage Ui50 V

Fusing-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force35 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force30 N

Overtravel5 mm

Locking force Fmax2500 N

Approach speedmax.20 m/min

Retention force20 N

Locking force FZh2000 N

Ready delay-

Shock and vibration resistance-

B10D5 x 10⁶

Connection cross-section0,34 ... 1,5 mm²

Switching voltage12 V

Short circuit protection according to IEC 60269-14A gG

Solenoid operating voltage24 V -15% ... +10%

Thermal rated current Ith4 A

Insertion depth24,5 mm

Utilization category acc. to EN 60947-5-14A 50V

Actuation frequencymax.1200 1/h

Number of door position NO contacts1

Number of guard lock monitoring positively driven contacts2

Number of door position NC contacts1

Switching principleSlow-action switching contac...

Contact materialSilver alloy, gold flashed

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 158763?
The price of 158763 on MQ Automation is $360.75. Order now.

Out if stock but available for backorder.

158763 Euchner - Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence, permanent magnet

What can I help you find today?

Recommended parts