158524 Euchner Safety Locking Systems

158524 on MQ Automation
Euchner
  • 158524
  • 158524
  • 158524

Part#:158524

Alt. Part#:MGBS-P-L2-AR-U-R-AZE-SH-158524

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

158524 Euchner - MGBS-AR, M23, emergency stop, 2 pushbuttons, door hinge on right

Product Details

  • Weight
    4.850164 lb
  • Series
    MGBS-AR
  • Product Class
    Safety System
  • B10D
    0,13 x 10⁶
  • Mission time
    20 y
  • PFHD
    4.1 x 10 ⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Additional feature
    Incl. cover set ID. No. 120344
  • Version
    Emergency stop
  • Switching element
    2 pos. driven NC
  • Repeat accuracy R
    10 %
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Turn-on time
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Switching current
    1 ... 150 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Output voltage
    UB-1,5 ... UB V DC
  • Power supply
    24 V
  • Operating current
    1 ... 50 mA
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Operating voltage
    UB V
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Connection rating
    6 W
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Fusing
    0,25 ... 8 A
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Rated insulation voltage Ui
    50 V
  • Current consumption
    40 mA
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Locking force Fmax
    3900 N
  • Actuating force
    10 N
  • Guard locking principle
    Open-circuit current principle
  • Test-pulse interval
    min.140 ms
  • Extraction force
    20 N
  • Connection
    1 plug connector M23, 19-pin, RC18
  • Approach speed
    max.20 m/min
  • Retention force
    20 N
  • Overtravel
    5 mm
  • Ambient temperature
    -20 ... +55 °C
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Mechanical life
    1 x 10⁶
  • Installation orientation
    Door hinge DIN right
  • Weight
    1,5 kg
  • Ready delay
    8 s
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Switching frequency
    max.0,5 Hz
  • Degree of protection
    IP65 (Screwed tight plug connector/mating component)
  • Housing material
    Die-cast zinc

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 158524 on MQ Automation is $1,313.26. Order now.


About the product

Locking module (order handle module separately);Adjustable door hinge; factory setting: right;Series connection possible (up to 20 AR devices in series);Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;Emergency stop;2 pushbuttons (illuminated);With plug connector M23;Unicode;Door position monitoring output


Manufacturer warranty

158524 Euchner

$1,313.26

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,313.26

$1,313.26 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 158524 with other products

Weight

Series

Product Class

B10D

Mission time

PFHD

Performance Level

Category

For the approval acc. to ...

Additional feature

Version

Switching element

Repeat accuracy R

Discrepancy time

Turn-on time

Off-state current Ir

Switching current

Type of output

Output voltage

Power supply

Operating current

Risk time according to EN...

Switching load

Operating voltage

Safety class

Degree of contamination (...

Connection rating

Solenoid duty cycle

EMC protection requiremen...

Utilization category acc....

Fusing

Solenoid operating voltag...

Rated impulse withstand v...

Rated insulation voltage ...

Current consumption

Operating voltage DC

Test pulses

Locking force Fmax

Actuating force

Guard locking principle

Test-pulse interval

Extraction force

Connection

Approach speed

Retention force

Overtravel

Ambient temperature

Locking force FZh

Mechanical life

Installation orientation

Ready delay

Shock and vibration resis...

Switching frequency

Degree of protection

Housing material

Extension of risk time ac...

Detent mechanism

Selected product

158524
0 in stock
158524
Euchner

158524 Euchner - MGBS-AR, M23, emergency stop, 2 pushbuttons, door hinge on right

Weight4.850164 lb

SeriesMGBS-AR

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureIncl. cover set ID. No. 1203...

VersionEmergency stop

Switching element2 pos. driven NC

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Output voltageUB-1,5 ... UB V DC

Power supply24 V

Operating current1 ... 50 mA

Risk time according to EN 60947-5-3max.260 ms

Switching load24V DC, class 2 (Alternativ...

Operating voltageUB V

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connection rating6 W

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.1,0 ms (Applies for a l...

Locking force Fmax3900 N

Actuating force10 N

Guard locking principleOpen-circuit current princip...

Test-pulse intervalmin.140 ms

Extraction force20 N

Connection1 plug connector M23, 19-pin...

Approach speedmax.20 m/min

Retention force20 N

Overtravel5 mm

Ambient temperature-20 ... +55 °C

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Mechanical life1 x 10⁶

Installation orientationDoor hinge DIN right

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Housing materialDie-cast zinc

Extension of risk time according to EN 60947-5-3 per device-

Detent mechanism-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Version-

Switching element-

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Output voltage0,8xUB ... UB V DC

Power supply-

Operating current-

Risk time according to EN 60947-5-3max.260 ms

Switching load24V DC, class 2 (Alternativ...

Operating voltage-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connection rating6 W

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.1,0 ms (Applies for a l...

Locking force Fmax3900 N

Actuating force10 N

Guard locking principleClosed-circuit current princ...

Test-pulse intervalmin.140 ms

Extraction force20 N

Connection2 plug connectors M12, 5 and...

Approach speedmax.20 m/min

Retention force20 N

Overtravel5 mm

Ambient temperature-20 ... +55 °C

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Mechanical life1 x 10⁶

Installation orientationAny

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Detent mechanism-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

VersionEmergency stop

Switching element2 pos. driven NC

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Output voltage0 ... 1 V DC

Power supply-

Operating current1 ... 100 mA

Risk time according to EN 60947-5-3-

Switching load24V DC, class 2 (Alternativ...

Operating voltage5 ... 24 V

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connection rating1 W

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Test pulsesmax.0,3 ms (Applies for a l...

Locking force Fmax-

Actuating force10 N

Guard locking principle-

Test-pulse intervalmin.100 ms

Extraction force20 N

Connection2 plug connectors M12, 5-pin

Approach speedmax.20 m/min

Retention force-

Overtravel5 mm

Ambient temperature-20 ... +55 °C

Locking force FZh-

Mechanical life1 x 10⁶

Installation orientationDoor hinge DIN right

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Extension of risk time according to EN 60947-5-3 per device-

Detent mechanismSnap-in bolt

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 158524?
The price of 158524 on MQ Automation is $1,313.26. Order now.

Out if stock but available for backorder.