157955 Euchner Safety Locking Systems

157955 on MQ Automation
Euchner
  • 157955
  • 157955

Part#:157955

Alt. Part#:MGB2-I-MLI-U-Y0000-JJ-157955

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

157955 Euchner - Interlocking module MGB2-I-MLI... (module without blanking covers)

Product Details

  • Weight
    2.2266662 lb
  • Series
    MGB2-MLI
  • Product Class
    Safety System
  • Performance Level
    PL e
  • PFHD
    2.62 x 10⁻⁹ (Fixed failure rate without consideration of faults in wearing parts.)
  • Mission time
    20
  • Category
    4
  • Diagnostic Coverage (DC)
    99
  • Auxiliary voltage DC
    24 V DC -25% ... 15%
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Transponder coding
    Unicode
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Operating voltage DC
    24 V DC -25% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Rated insulation voltage Ui
    75 V
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Safety class
    III
  • EMC protection requirements
    EMC directive 2014/30/EU
  • Current consumption
    max.75 mA
  • Weight
    1,0 kg
  • Degree of protection
    IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Reaction time
    See operating instructions for bus module MBM-...
  • Ambient temperature
    -25 ... 55 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Housing material
    Fiber glass reinforced plastic, die-cast zinc, nickel plated

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 157955 on MQ Automation is $923.43. Order now.


About the product

Interlocking (without guard locking);Interlocking module MGB2 for connection to a bus module MBM;Category 4/PL e for the evaluation of all safety functions;Open version (without blanking covers);Adjustable door hinge;Unicode;Compatible with all Modular devices


Manufacturer warranty

157955 Euchner

$923.43

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$923.43

$923.43 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 157955 with other products

Weight

Series

Product Class

Performance Level

PFHD

Mission time

Category

Diagnostic Coverage (DC)

Auxiliary voltage DC

Safety Integrity Level

Transponder coding

Degree of contamination (...

Operating voltage DC

Rated insulation voltage ...

Rated impulse withstand v...

Safety class

EMC protection requiremen...

Current consumption

Degree of protection

Mechanical life

Switching frequency

Reaction time

Ambient temperature

Shock and vibration resis...

Housing material

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Utilization category acc....

Rated conditional short-c...

Test pulses

Test-pulse interval

Output voltage

Switching current

Turn-on time

Risk time according to EN...

Type of output

Fusing

Extension of risk time ac...

Tightening torque

Installation orientation

Mounting distance

Connection

Ready delay

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

157955
0 in stock
157955
Euchner

157955 Euchner - Interlocking module MGB2-I-MLI... (module without blanking covers)

Weight2.2266662 lb

SeriesMGB2-MLI

Product ClassSafety System

Performance LevelPL e

PFHD2.62 x 10⁻⁹ (Fixed failure ...

Mission time20

Category4

Diagnostic Coverage (DC)99

Auxiliary voltage DC24 V DC -25% ... 15%

Safety Integrity LevelSIL 3 (EN 62061:2005)

Transponder codingUnicode

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC -25% ... 15% ((Re...

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

EMC protection requirementsEMC directive 2014/30/EU

Current consumptionmax.75 mA

Degree of protectionIP65 (This is the case only...

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Reaction timeSee operating instructions f...

Ambient temperature-25 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialFiber glass reinforced plast...

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Utilization category acc. to EN 60947-5-2-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Switching current-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Installation orientation-

Mounting distance-

Connection-

Ready delay-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Performance LevelPL e

PFHD1.9 x 10⁻⁹

Mission time20

Category4

Diagnostic Coverage (DC)-

Auxiliary voltage DC-

Safety Integrity Level-

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC 15% ... 15% Regu...

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumptionmax.50 mA (Without taking i...

Degree of protectionIP67

Mechanical life-

Switching frequencymax.1 Hz

Reaction time-

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialPlastic, PBT

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Installation orientationAny

Mounting distancemin.120 mm

ConnectionConnection cable PUR, length...

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Performance LevelPL e

PFHD1.8 x 10⁻⁹

Mission time20

Category4

Diagnostic Coverage (DC)-

Auxiliary voltage DC-

Safety Integrity Level-

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC 15% ... 15% Regu...

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Current consumptionmax.30 mA (Without taking i...

Degree of protectionIP67, IP69K

Mechanical life-

Switching frequencymax.1 Hz

Reaction time-

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialPlastic, PBT

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated conditional short-circuit current100 A

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Turn-on timemax.300 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Extension of risk time according to EN 60947-5-3 per device-

Tightening torquemax.1 Nm

Installation orientationAny

Mounting distancemin.400 mm

Connectionconnection cable PVC, length...

Ready delay0,5 s

Cable ambient temperature (dynamic)0 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-40 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 157955?
The price of 157955 on MQ Automation is $923.43. Order now.

Out if stock but available for backorder.

157955 Euchner - Interlocking module MGB2-I-MLI... (module without blanking covers)

What can I help you find today?

Recommended parts