157849 Euchner Safety Accessories

157849 on MQ Automation
Euchner
  • 157849
  • 157849
  • 157849

Part#:157849

Alt. Part#:MGB-L1-ARA-AN3A1-S1-L-157849

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

157849 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, key-operated rotary switch, IP54, RC 18

Product Details

  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Product version number
    V4.0.0
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    1NO
  • Power supply LED
    24 V DC
  • Assignment diagram
    L1
  • Version
    Key-operated switch
  • Breaking capacity
    max.0,25 W
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Output current
    1 ... 200 mA
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Current consumption
    max.80 mA ((no load on outputs))
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.5 ms
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Transponder coding
    Unicode
  • Safety class
    III
  • Discrepancy time
    max.10 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Rated insulation voltage Ui
    30 V
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Mechanical life
    0,1 x 10⁶
  • Locking force FZh
    2000 N
  • Connection
    Plug connector RC 18 (X6)
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Installation orientation
    Door hinge DIN left
  • Guard locking principle
    Closed-circuit current principle
  • Degree of protection
    IP54
  • Switching frequency
    0,25 Hz
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 157849 on MQ Automation is $1,441.88. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Key-operated rotary switch (form L, 90°);2 pushbuttons (illuminated);With lens set, 6 pcs.;With plug connector RC18;Unicode;IP54


Manufacturer warranty

157849 Euchner

$1,441.88

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,441.88

$1,441.88 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 157849 with other products

Series

Product Class

Mission time

PFHD

Performance Level

Category

Product version number

Additional feature

Switching element

Power supply LED

Assignment diagram

Version

Breaking capacity

Switching current

Switching voltage

Output voltage

Output current

Operating voltage DC

Current consumption

Type of output

Test-pulse interval

Test pulses

Risk time according to EN...

Transponder coding

Safety class

Discrepancy time

Degree of contamination (...

Connection cross-section

Rated insulation voltage ...

Rated impulse withstand v...

Utilization category acc....

Mechanical life

Locking force FZh

Connection

Ambient temperature

Housing material

Installation orientation

Guard locking principle

Degree of protection

Switching frequency

Weight

For the approval acc. to ...

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

B10D

Operating current

Detent mechanism

Operating voltage

Selected product

157849
0 in stock
157849
Euchner

157849 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, ke...

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4

Product version numberV4.0.0

Additional featureIncl. cover set ID. No. 1203...

Switching element1NO

Power supply LED24 V DC

Assignment diagramL1

VersionKey-operated switch

Breaking capacitymax.0,25 W

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Output voltageUB-2V ... UB V DC (Value at...

Output current1 ... 200 mA

Operating voltage DC24 V DC -15% ... 10% ((Re...

Current consumptionmax.80 mA ((no load on outp...

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Test pulsesmax.5 ms

Risk time according to EN 60947-5-3max.350 ms

Transponder codingUnicode

Safety classIII

Discrepancy timemax.10 ms

Degree of contamination (external, according to EN 60947-1)3

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Rated insulation voltage Ui30 V

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Mechanical life0,1 x 10⁶

Locking force FZh2000 N

ConnectionPlug connector RC 18 (X6)

Ambient temperature-20 ... 55 °C

Housing materialReinforced plastic; die-cast...

Installation orientationDoor hinge DIN left

Guard locking principleClosed-circuit current princ...

Degree of protectionIP54

Switching frequency0,25 Hz

Weight0,75 kg

For the approval acc. to UL the following applies-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Additional featureEscape release actuated by p...

Switching element-

Power supply LED-

Assignment diagram-

Version-

Breaking capacity-

Switching current1 ... 50 mA

Switching voltage-

Output voltage0,8xUB ... UB V DC

Output current-

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Risk time according to EN 60947-5-3max.260 ms

Transponder coding-

Safety classIII

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Connection cross-section-

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Mechanical life1 x 10⁶

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Installation orientationAny

Guard locking principleClosed-circuit current princ...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Switching frequencymax.0,5 Hz

Weight1.763696 lb

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Product version number-

Additional feature-

Switching element2 pos. driven NC

Power supply LED-

Assignment diagram-

VersionEmergency stop

Breaking capacity-

Switching current1 ... 150 mA

Switching voltage-

Output voltage0 ... 1 V DC

Output current-

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Risk time according to EN 60947-5-3-

Transponder coding-

Safety classIII

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Connection cross-section-

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Mechanical life1 x 10⁶

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Installation orientationDoor hinge DIN right

Guard locking principle-

Degree of protectionIP65 (Screwed tight plug co...

Switching frequencymax.0,5 Hz

Weight3.968316 lb

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 157849?
The price of 157849 on MQ Automation is $1,441.88. Order now.

Out if stock but available for backorder.

157849 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, key-operated rotary switch, IP54, RC 18

What can I help you find today?

Recommended parts