156001 Euchner Safety Accessories

156001 on MQ Automation
Euchner
  • 156001
  • 156001
  • 156001

Part#:156001

Alt. Part#:MGB-L1-APA-AD3A1-S9-L-156001

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

156001 Euchner - Locking module MGB-L1-APA..., (guard locking by spring force) with 3 pushbuttons, 2 x M12

Product Details

  • Weight
    2.3589434 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Product version number
    V4.0.0
  • Category
    4
  • Breaking capacity
    max.0,25 W
  • Switching element
    1NO
  • Color
    Blue
  • Version
    Illuminated push buttons
  • Assignment diagram
    L1
  • Power supply LED
    24 V DC
  • Switching current
    1 ... 10 mA
  • Switching voltage
    UA V
  • Output current
    1 ... 200 mA
  • Output voltage
    0 ... 1 V DC
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.0,3 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Current consumption
    max.80 mA ((no load on outputs))
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Locking force FZh
    2000 N
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Guard locking principle
    Closed-circuit current principle
  • Mechanical life
    0,1 x 10⁶
  • Degree of protection
    IP65
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Weight
    0,75 kg
  • Connection
    Plug connector SM5 (X6)
  • Switching frequency
    0,25 Hz
  • Installation orientation
    Door hinge DIN left
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 156001 on MQ Automation is $1,557.85. Order now.


About the product

Guard locking with guard lock monitoring;3 pushbuttons (illuminated, bu, wh, wh);With plug connector M12, 5-pin;With plug connector M12, 8-pin;Unicode;Connection for Bihl-Wiedemann modules BW 3376 and BW 3377


Manufacturer warranty

156001 Euchner

$1,557.85

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,557.85

$1,557.85 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 156001 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Product version number

Category

Breaking capacity

Switching element

Color

Version

Assignment diagram

Power supply LED

Switching current

Switching voltage

Output current

Output voltage

Test-pulse interval

Test pulses

Type of output

Operating voltage DC

Transponder coding

Current consumption

Risk time according to EN...

Discrepancy time

Degree of contamination (...

Safety class

Rated impulse withstand v...

Locking force FZh

Rated insulation voltage ...

Utilization category acc....

Guard locking principle

Mechanical life

Degree of protection

Housing material

Connection

Switching frequency

Installation orientation

Ambient temperature

For the approval acc. to ...

Additional feature

Repeat accuracy R

Turn-on time

Off-state current Ir

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Solenoid operating voltag...

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

Shock and vibration resis...

B10D

Operating current

Detent mechanism

Operating voltage

Selected product

156001
0 in stock
156001
Euchner

156001 Euchner - Locking module MGB-L1-APA..., (guard locking by spring force) with 3 pushbuttons, 2...

Weight2.3589434 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Product version numberV4.0.0

Category4

Breaking capacitymax.0,25 W

Switching element1NO

ColorBlue

VersionIlluminated push buttons

Assignment diagramL1

Power supply LED24 V DC

Switching current1 ... 10 mA

Switching voltageU<sub>A</sub> V

Output current1 ... 200 mA

Output voltage0 ... 1 V DC

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms

Type of outputSemiconductor outputs, p-swi...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingUnicode

Current consumptionmax.80 mA ((no load on outp...

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

Locking force FZh2000 N

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Mechanical life0,1 x 10⁶

Degree of protectionIP65

Housing materialReinforced plastic; die-cast...

ConnectionPlug connector SM5 (X6)

Switching frequency0,25 Hz

Installation orientationDoor hinge DIN left

Ambient temperature-20 ... 55 °C

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Turn-on time-

Off-state current Ir-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Solenoid operating voltage DC-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

Shock and vibration resistance-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Product version number-

Category4

Breaking capacity-

Switching element-

Color-

Version-

Assignment diagram-

Power supply LED-

Switching current1 ... 50 mA

Switching voltage-

Output current-

Output voltage0,8xUB ... UB V DC

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Type of outputp-switching, short circuit-p...

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Current consumption40 mA

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Installation orientationAny

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D-

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Product version number-

Category4

Breaking capacity-

Switching element2 pos. driven NC

Color-

VersionEmergency stop

Assignment diagram-

Power supply LED-

Switching current1 ... 150 mA

Switching voltage-

Output current-

Output voltage0 ... 1 V DC

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Type of output2 semiconductor outputs, p-s...

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Current consumption40 mA

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh-

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principle-

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R10 %

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 156001?
The price of 156001 on MQ Automation is $1,557.85. Order now.

Out if stock but available for backorder.

156001 Euchner - Locking module MGB-L1-APA..., (guard locking by spring force) with 3 pushbuttons, 2 x M12

What can I help you find today?

Recommended parts