138012 Euchner Safety Locking Systems

138012 on MQ Automation
Euchner
  • 138012
  • 138012

Part#:138012

Alt. Part#:MGB2-L2-BR-U-X0000-BX-138012

Manufacturer:Euchner

Category:Safety Locking Systems

Product Lifecycle:Active

Product description

138012 Euchner - Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current principle)

Product Details

  • Weight
    2.6014516 lb
  • Series
    MGB2-L.-BR
  • Product Class
    Safety System
  • Mission time
    20 y
  • Diagnostic Coverage (DC)
    99
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Output current
    1 ... 150 mA
  • Performance Level
    PL e
  • PFHD
    2.95 x 10⁻⁹
  • Category
    4
  • Product version number
    V1.0.3
  • Turn-on time
    max.80 ms
  • Output voltage
    0 ... 1 V DC
  • Test-pulse interval
    min.100 ms
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test pulses
    max.5 ms
  • Solenoid operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Current consumption
    max.80 mA (at 20.4 V including safety inputs FI1A and FI1B, no load on outputs)
  • Discrepancy time
    max.10 ms
  • Operating voltage DC
    24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Risk time according to EN 60947-5-3
    max.50 ms (In a series connection, the risk time increases by 10 ms per each additional device.)
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Connection cross-section
    0,25 ... 1,5 mm² ((AWG 23 ... AWG 16))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    75 V
  • Locking force FZh
    2000 N
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Guard locking principle
    Open-circuit current principle
  • Switching frequency
    0,25 Hz
  • Mechanical life
    0,1 x 10⁶
  • Degree of protection
    IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.)
  • Ready delay
    5 s
  • Ambient temperature
    -25 ... 55 °C
  • Weight
    1,00 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Housing material
    Glass fiber reinforced plastic; die-cast zinc, nickel-plated

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 138012 on MQ Automation is $849.33. Order now.


About the product

Guard locking for the protection of persons or processes;Locking module MGB2 for direct connection to a control system;Configurable as interlocking or guard locking;Category 4/PL e for the evaluation of all safety functions;Open version (without blanking covers);Adjustable door hinge;Unicode;Compatible with BR technology


Manufacturer warranty

138012 Euchner

$849.33

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$849.33

$849.33 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 138012 with other products

Weight

Series

Product Class

Mission time

Diagnostic Coverage (DC)

Safety Integrity Level

Output current

Performance Level

PFHD

Category

Product version number

Turn-on time

Output voltage

Test-pulse interval

Type of output

Test pulses

Solenoid operating voltag...

Transponder coding

Current consumption

Discrepancy time

Operating voltage DC

Risk time according to EN...

Safety class

Rated impulse withstand v...

Connection cross-section

Degree of contamination (...

Rated insulation voltage ...

Locking force FZh

Utilization category acc....

Guard locking principle

Switching frequency

Mechanical life

Degree of protection

Ready delay

Ambient temperature

Shock and vibration resis...

Housing material

For the approval acc. to ...

Additional feature

Repeat accuracy R

Off-state current Ir

Switching current

Switching load

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Connection

Installation orientation

Assured release distance ...

Operating distance

Switching hysteresis

Assured operating distanc...

Rated conditional short-c...

Tightening torque

Static bending radius

Dynamic bending radius

Mounting distance

Mounting method

Cable ambient temperature...

Cable ambient temperature...

Selected product

138012
0 in stock
138012
Euchner

138012 Euchner - Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current ...

Weight2.6014516 lb

SeriesMGB2-L.-BR

Product ClassSafety System

Mission time20 y

Diagnostic Coverage (DC)99

Safety Integrity LevelSIL 3 (EN 62061:2005)

Output current1 ... 150 mA

Performance LevelPL e

PFHD2.95 x 10⁻⁹

Category4

Product version numberV1.0.3

Turn-on timemax.80 ms

Output voltage0 ... 1 V DC

Test-pulse intervalmin.100 ms

Type of outputSemiconductor outputs, p-swi...

Test pulsesmax.5 ms

Solenoid operating voltage DC24 V DC -15% ... 15% ((Re...

Transponder codingUnicode

Current consumptionmax.80 mA (at 20.4 V includ...

Discrepancy timemax.10 ms

Operating voltage DC24 V DC -15% ... 15% ((Re...

Risk time according to EN 60947-5-3max.50 ms (In a series conn...

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

Connection cross-section0,25 ... 1,5 mm² ((AWG 23 ....

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Locking force FZh2000 N

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principleOpen-circuit current princip...

Switching frequency0,25 Hz

Mechanical life0,1 x 10⁶

Degree of protectionIP65 (This is the case only...

Ready delay5 s

Ambient temperature-25 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialGlass fiber reinforced plast...

For the approval acc. to UL the following applies-

Additional feature-

Repeat accuracy R-

Off-state current Ir-

Switching current-

Switching load-

Solenoid duty cycle-

EMC protection requirements-

Connection rating-

Fusing-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connection-

Installation orientation-

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Diagnostic Coverage (DC)-

Safety Integrity Level-

Output current-

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Category4

Product version number-

Turn-on timemax.400 ms

Output voltage0,8xUB ... UB V DC

Test-pulse intervalmin.140 ms

Type of outputp-switching, short circuit-p...

Test pulsesmax.1,0 ms (Applies for a l...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Transponder coding-

Current consumption40 mA

Discrepancy timemax.10 ms In acc. with EN ...

Operating voltage DC24 V DC -15% ... 15% Rev...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ready delay8 s

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureEscape release actuated by p...

Repeat accuracy R10 %

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Assured release distance Sar-

Operating distance-

Switching hysteresis-

Assured operating distance Sao-

Rated conditional short-circuit current-

Tightening torque-

Static bending radius-

Dynamic bending radius-

Mounting distance-

Mounting method-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

SeriesCES-AP

Product ClassSafety System

Mission time20

Diagnostic Coverage (DC)-

Safety Integrity Level-

Output current-

Performance LevelPL e

PFHD1.8 x 10⁻⁹

Category4

Product version number-

Turn-on timemax.300 ms

Output voltage0,8 x UB ... UB V DC

Test-pulse intervalmin.100 ms

Type of outputp-switching, short circuit-p...

Test pulsesmax.0,3 ms (Applies for a l...

Solenoid operating voltage DC-

Transponder coding-

Current consumptionmax.30 mA (Without taking i...

Discrepancy timemax.10 ms

Operating voltage DC24 V DC 15% ... 15% Regu...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Locking force FZh-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principle-

Switching frequencymax.1 Hz

Mechanical life-

Degree of protectionIP67, IP69K

Ready delay0,5 s

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialPlastic, PBT

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Switching currentmax.50 mA

Switching load-

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Connectionconnection cable PVC, length...

Installation orientationAny

Assured release distance Sarmax.60 mm

Operating distance19 mm

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Rated conditional short-circuit current100 A

Tightening torquemax.1 Nm

Static bending radius5 x cable diameter

Dynamic bending radius10 x cable diameter

Mounting distancemin.400 mm

Mounting methodSurface mounting on metal

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 138012?
The price of 138012 on MQ Automation is $849.33. Order now.

Out if stock but available for backorder.

138012 Euchner - Locking module MGB2-L2-BR... (module without blanking covers, open-circuit current principle)

What can I help you find today?

Recommended parts