136774 Euchner Safety Locking Systems
Part#:136774
Alt. Part#:MGB2-L1-BR-U-X0000-BX-136774
Manufacturer:Euchner
Category:Safety Locking Systems
Product Lifecycle:Active
Product description
136774 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit current principle)
Product Details
- Weight 2.6014516 lb
- Series MGB2-L.-BR
- Product Class Safety System
- Product version number V1.0.3
- Performance Level PL e
- Mission time 20 y
- Safety Integrity Level SIL 3 (EN 62061:2005)
- Category 4
- Diagnostic Coverage (DC) 99
- Current consumption max.375 mA
- Solenoid operating voltage DC 24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- PFHD 2.95 x 10⁻⁹
- Test-pulse interval min.100 ms
- Turn-on time max.80 ms
- Operating voltage DC 24 V DC -15% ... 15% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Output current 1 ... 150 mA
- Test pulses max.0,3 ms
- Output voltage UB-2 ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
- Type of output Semiconductor outputs, p-switching, short circuit-proof
- Transponder coding Unicode
- Discrepancy time max.10 ms
- Risk time according to EN 60947-5-3 max.50 ms (In a series connection, the risk time increases by 10 ms per each additional device.)
- Connection cross-section 0,25 ... 1,5 mm²
- Safety class III
- Degree of contamination (external, according to EN 60947-1) 3
- Rated impulse withstand voltage Uimp 1,5 kV
- Utilization category acc. to EN 60947-5-2 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
- Locking force FZh 2000 N
- Rated insulation voltage Ui 75 V
- Guard locking principle Closed-circuit current principle
- Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables, submodules and connection submodules.)
- Ready delay 5 s
- Weight 1,00 kg
- Mechanical life 0,1 x 10⁶
- Ambient temperature -25 ... 55 °C
- Housing material Glass fiber reinforced plastic; die-cast zinc, nickel-plated
- Shock and vibration resistance In acc. with EN 60947-5-3
- Switching frequency 0,25 Hz
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 136774 on MQ Automation is $849.33. Order now.
About the product
Guard locking for the protection of persons or processes;Locking module MGB2 for direct connection to a control system;Configurable as interlocking or guard locking;Category 4/PL e for the evaluation of all safety functions;Open version (without blanking covers);Adjustable door hinge;Unicode;Compatible with BR technology
Manufacturer warranty
136774 Euchner
$849.33
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$849.33
$849.33 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 136774 with other products
Weight
Series
Product Class
Product version number
Performance Level
Mission time
Safety Integrity Level
Category
Diagnostic Coverage (DC)
Current consumption
Solenoid operating voltag...
PFHD
Test-pulse interval
Turn-on time
Operating voltage DC
Output current
Test pulses
Output voltage
Type of output
Transponder coding
Discrepancy time
Risk time according to EN...
Connection cross-section
Safety class
Degree of contamination (...
Rated impulse withstand v...
Utilization category acc....
Locking force FZh
Rated insulation voltage ...
Guard locking principle
Degree of protection
Ready delay
Mechanical life
Ambient temperature
Housing material
Shock and vibration resis...
Switching frequency
For the approval acc. to ...
Additional feature
Repeat accuracy R
Off-state current Ir
Switching current
Switching load
Solenoid duty cycle
EMC protection requiremen...
Connection rating
Fusing
Actuating force
Extension of risk time ac...
Extraction force
Overtravel
Locking force Fmax
Approach speed
Retention force
Connection
Installation orientation
Assured release distance ...
Operating distance
Switching hysteresis
Assured operating distanc...
Rated conditional short-c...
Tightening torque
Static bending radius
Dynamic bending radius
Mounting distance
Mounting method
Cable ambient temperature...
Cable ambient temperature...
Selected product

136774
Euchner
136774 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit curren...
Weight2.6014516 lb
SeriesMGB2-L.-BR
Product ClassSafety System
Product version numberV1.0.3
Performance LevelPL e
Mission time20 y
Safety Integrity LevelSIL 3 (EN 62061:2005)
Category4
Diagnostic Coverage (DC)99
Current consumptionmax.375 mA
Solenoid operating voltage DC24 V DC -15% ... 15% ((Re...
PFHD2.95 x 10⁻⁹
Test-pulse intervalmin.100 ms
Turn-on timemax.80 ms
Operating voltage DC24 V DC -15% ... 15% ((Re...
Output current1 ... 150 mA
Test pulsesmax.0,3 ms
Output voltageUB-2 ... UB V DC (Value at ...
Type of outputSemiconductor outputs, p-swi...
Transponder codingUnicode
Discrepancy timemax.10 ms
Risk time according to EN 60947-5-3max.50 ms (In a series conn...
Connection cross-section0,25 ... 1,5 mm²
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp1,5 kV
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Locking force FZh2000 N
Rated insulation voltage Ui75 V
Guard locking principleClosed-circuit current princ...
Degree of protectionIP65 (This is the case only...
Ready delay5 s
Mechanical life0,1 x 10⁶
Ambient temperature-25 ... 55 °C
Housing materialGlass fiber reinforced plast...
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching frequency0,25 Hz
For the approval acc. to UL the following applies-
Additional feature-
Repeat accuracy R-
Off-state current Ir-
Switching current-
Switching load-
Solenoid duty cycle-
EMC protection requirements-
Connection rating-
Fusing-
Actuating force-
Extension of risk time according to EN 60947-5-3 per device-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Connection-
Installation orientation-
Assured release distance Sar-
Operating distance-
Switching hysteresis-
Assured operating distance Sao-
Rated conditional short-circuit current-
Tightening torque-
Static bending radius-
Dynamic bending radius-
Mounting distance-
Mounting method-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-

122813
Euchner
122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release
Weight1.763696 lb
SeriesCTP-AR
Product ClassSafety System
Product version number-
Performance LevelPL e
Mission time20 y
Safety Integrity Level-
Category4
Diagnostic Coverage (DC)-
Current consumption40 mA
Solenoid operating voltage DC24 V DC -15% ... +10% Re...
PFHD4.1 x 10 ⁻⁹
Test-pulse intervalmin.140 ms
Turn-on timemax.400 ms
Operating voltage DC24 V DC -15% ... 15% Rev...
Output current-
Test pulsesmax.1,0 ms (Applies for a l...
Output voltage0,8xUB ... UB V DC
Type of outputp-switching, short circuit-p...
Transponder coding-
Discrepancy timemax.10 ms In acc. with EN ...
Risk time according to EN 60947-5-3max.260 ms
Connection cross-section-
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp0,5 kV
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...
Rated insulation voltage Ui50 V
Guard locking principleClosed-circuit current princ...
Degree of protectionIP67/IP69/IP69K (Screwed ti...
Ready delay8 s
Mechanical life1 x 10⁶
Ambient temperature-20 ... +55 °C
Housing materialDie-cast zinc
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching frequencymax.0,5 Hz
For the approval acc. to UL the following appliesOperation only with UL class...
Additional featureEscape release actuated by p...
Repeat accuracy R10 %
Off-state current Irmax.0,25 mA
Switching current1 ... 50 mA
Switching load24V DC, class 2 (Alternativ...
Solenoid duty cycle100 %
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Connection rating6 W
Fusing0,25 ... 8 A
Actuating force10 N
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Extraction force20 N
Overtravel5 mm
Locking force Fmax3900 N
Approach speedmax.20 m/min
Retention force20 N
Connection2 plug connectors M12, 5 and...
Installation orientationAny
Assured release distance Sar-
Operating distance-
Switching hysteresis-
Assured operating distance Sao-
Rated conditional short-circuit current-
Tightening torque-
Static bending radius-
Dynamic bending radius-
Mounting distance-
Mounting method-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
Weight0.52029032 lb
SeriesCES-AP
Product ClassSafety System
Product version number-
Performance LevelPL e
Mission time20
Safety Integrity Level-
Category4
Diagnostic Coverage (DC)-
Current consumptionmax.30 mA (Without taking i...
Solenoid operating voltage DC-
PFHD1.8 x 10⁻⁹
Test-pulse intervalmin.100 ms
Turn-on timemax.300 ms
Operating voltage DC24 V DC 15% ... 15% Regu...
Output current-
Test pulsesmax.0,3 ms (Applies for a l...
Output voltage0,8 x UB ... UB V DC
Type of outputp-switching, short circuit-p...
Transponder coding-
Discrepancy timemax.10 ms
Risk time according to EN 60947-5-3max.260 ms
Connection cross-section-
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp1,5 kV
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Locking force FZh-
Rated insulation voltage Ui75 V
Guard locking principle-
Degree of protectionIP67, IP69K
Ready delay0,5 s
Mechanical life-
Ambient temperature-
Housing materialPlastic, PBT
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching frequencymax.1 Hz
For the approval acc. to UL the following appliesOperation only with UL class...
Additional feature-
Repeat accuracy R≤ 10
Off-state current Irmax.0,25 mA
Switching currentmax.50 mA
Switching load-
Solenoid duty cycle-
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Connection rating-
Fusing0,25 ... 8 A
Actuating force-
Extension of risk time according to EN 60947-5-3 per device-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Connectionconnection cable PVC, length...
Installation orientationAny
Assured release distance Sarmax.60 mm
Operating distance19 mm
Switching hysteresismin.1 mm
Assured operating distance Saomin.14 mm
Rated conditional short-circuit current100 A
Tightening torquemax.1 Nm
Static bending radius5 x cable diameter
Dynamic bending radius10 x cable diameter
Mounting distancemin.400 mm
Mounting methodSurface mounting on metal
Cable ambient temperature (static)-40 ... 65 °C
Cable ambient temperature (dynamic)0 ... 65 °C

136774
Euchner
136774 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit curren...
Weight2.6014516 lb
SeriesMGB2-L.-BR
Product ClassSafety System
Product version numberV1.0.3
Performance LevelPL e
Mission time20 y
Safety Integrity LevelSIL 3 (EN 62061:2005)
Category4
Diagnostic Coverage (DC)99
Current consumptionmax.375 mA
Solenoid operating voltage DC24 V DC -15% ... 15% ((Re...
PFHD2.95 x 10⁻⁹
Test-pulse intervalmin.100 ms
Turn-on timemax.80 ms
Operating voltage DC24 V DC -15% ... 15% ((Re...
Output current1 ... 150 mA
Test pulsesmax.0,3 ms
Output voltageUB-2 ... UB V DC (Value at ...
Type of outputSemiconductor outputs, p-swi...
Transponder codingUnicode
Discrepancy timemax.10 ms
Risk time according to EN 60947-5-3max.50 ms (In a series conn...
Connection cross-section0,25 ... 1,5 mm²
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Rated impulse withstand voltage Uimp1,5 kV
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Locking force FZh2000 N
Rated insulation voltage Ui75 V
Guard locking principleClosed-circuit current princ...
Degree of protectionIP65 (This is the case only...
Ready delay5 s
Mechanical life0,1 x 10⁶
Ambient temperature-25 ... 55 °C
Housing materialGlass fiber reinforced plast...
Shock and vibration resistanceIn acc. with EN 60947-5-3
Switching frequency0,25 Hz
For the approval acc. to UL the following applies-
Additional feature-
Repeat accuracy R-
Off-state current Ir-
Switching current-
Switching load-
Solenoid duty cycle-
EMC protection requirements-
Connection rating-
Fusing-
Actuating force-
Extension of risk time according to EN 60947-5-3 per device-
Extraction force-
Overtravel-
Locking force Fmax-
Approach speed-
Retention force-
Connection-
Installation orientation-
Assured release distance Sar-
Operating distance-
Switching hysteresis-
Assured operating distance Sao-
Rated conditional short-circuit current-
Tightening torque-
Static bending radius-
Dynamic bending radius-
Mounting distance-
Mounting method-
Cable ambient temperature (static)-
Cable ambient temperature (dynamic)-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 136774?
The price of 136774 on MQ Automation is $849.33. Order now.
Out if stock but available for backorder.
136774 Euchner - Locking module MGB2-L1-BR... (module without blanking covers, closed-circuit current principle)
Similar products from: Safety Locking Systems
What can I help you find today?