128193 Euchner Safety Proximity Sensors

128193 on MQ Automation
Euchner
  • 128193
  • 128193
  • 128193

Part#:128193

Alt. Part#:CET4-AR-CRA-AH-50X-SG-C2290-128193

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

128193 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden) (3 m)

Product Details

  • Weight
    4.00579454 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • PFHD
    Depending on external control of guard locking (Teach-in input and LEDs have the same ground potential as the guard locking solenoid)
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Switching delay from state change
    max.400 ms
  • Performance Level
    Depending on external control of guard locking (Teach-in input and LEDs have the same ground potential as the guard locking solenoid)
  • Category
    Depending on external control of guard locking (Teach-in input and LEDs have the same ground potential as the guard locking solenoid)
  • Turn-on time
    400 ms
  • Repeat accuracy R
    10 %
  • Off-state current Ir
    max.0,25 mA
  • Discrepancy time
    max.10 ms
  • Output voltage
    UB-1,5V ... UB V DC
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Switching current
    1 ... 200 mA
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Input voltage
    15 ... 27,6 V DC
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Safety class
    III
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    11 W
  • Fusing
    0,25 ... 8 A
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    80 mA
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Locking force Fmax
    6500 N
  • Guard locking principle
    Open-circuit current principle
  • Approach speed
    max.20 m/min
  • Switching frequency
    max.0,5 Hz
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Ready delay
    10 s
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Degree of freedom Y
    ±5 mm
  • Degree of freedom Z
    ±4 mm
  • Installation orientation
    Any (Preferably head downward)
  • Degree of freedom X
    ±5 mm
  • Housing material
    Stainless steel
  • Weight
    1 kg
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Mechanical life
    1 x 10⁶

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 128193 on MQ Automation is $1,083.36. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;Indication of the door position by LED;Teach-in input;Wire front release (bowden), 3 m;Approach direction A (delivery state)


Manufacturer warranty

128193 Euchner

$1,083.36

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,083.36

$1,083.36 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 128193 with other products

Weight

Series

Product Class

Mission time

PFHD

For the approval acc. to ...

Switching delay from stat...

Performance Level

Category

Turn-on time

Repeat accuracy R

Off-state current Ir

Discrepancy time

Output voltage

Type of output

Risk time according to EN...

Switching current

Extension of risk time ac...

Input voltage

Switching load

Connecting cable

Degree of contamination (...

Safety class

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Utilization category acc....

Solenoid operating voltag...

Current consumption

Operating voltage DC

Locking force FZh

Locking force Fmax

Guard locking principle

Approach speed

Switching frequency

Connection

Ready delay

Shock and vibration resis...

Degree of freedom Y

Degree of freedom Z

Installation orientation

Degree of freedom X

Housing material

Ambient temperature

Degree of protection

Mechanical life

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

128193
0 in stock
128193
Euchner

128193 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden) (3 m)

Weight4.00579454 lb

SeriesCET-AR

Product ClassSafety System

Mission time20 y

PFHDDepending on external contro...

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state changemax.400 ms

Performance LevelDepending on external contro...

CategoryDepending on external contro...

Turn-on time400 ms

Repeat accuracy R10 %

Off-state current Irmax.0,25 mA

Discrepancy timemax.10 ms

Output voltageUB-1,5V ... UB V DC

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3max.400 ms

Switching current1 ... 200 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Input voltage15 ... 27,6 V DC

Switching load24V DC, class 2 (For altern...

Connecting cable30V DC, 2A (For UL requirem...

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating11 W

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption80 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh5000 N (FZH = FMAX/1.3)

Locking force Fmax6500 N

Guard locking principleOpen-circuit current princip...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Ready delay10 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom Y±5 mm

Degree of freedom Z±4 mm

Installation orientationAny (Preferably head downwa...

Degree of freedom X±5 mm

Housing materialStainless steel

Ambient temperature-20 ... 55 °C

Degree of protectionIP67 (Screwed tight plug co...

Mechanical life1 x 10⁶

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Performance LevelPL e

Category4

Turn-on timemax.400 ms

Repeat accuracy R10 %

Off-state current Irmax.0,25 mA

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Switching current1 ... 50 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Input voltage-

Switching load24V DC, class 2 (Alternativ...

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Ready delay8 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom Y-

Degree of freedom Z-

Installation orientationAny

Degree of freedom X-

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mechanical life1 x 10⁶

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Performance LevelPL e

Category4

Turn-on timemax.400 ms

Repeat accuracy R10 %

Off-state current Irmax.0,25 mA

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3-

Switching current1 ... 150 mA

Extension of risk time according to EN 60947-5-3 per device-

Input voltage-

Switching load24V DC, class 2 (Alternativ...

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Solenoid operating voltage DC-

Current consumption40 mA

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh-

Locking force Fmax-

Guard locking principle-

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Ready delaymax.1 s

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom Y-

Degree of freedom Z-

Installation orientationDoor hinge DIN right

Degree of freedom X-

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Mechanical life1 x 10⁶

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 128193?
The price of 128193 on MQ Automation is $1,083.36. Order now.

Out if stock but available for backorder.

128193 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden) (3 m)

What can I help you find today?

Recommended parts