125577 Euchner Safety Accessories

125577 on MQ Automation
Euchner
  • 125577
  • 125577

Part#:125577

Alt. Part#:MGB-L2B-PNA-L-125577

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

125577 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 2 control elements, 7/8" and M12 plugs

Product Details

  • Weight
    6.61386 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Diagnostic Coverage (DC)
    99
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Category
    4
  • Performance Level
    PL e
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    1NO
  • Product version number
    V3.30.10
  • Version
    Illuminated push buttons
  • Assignment diagram
    B1
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Fusing
    min.1 A Slow blow
  • Transponder coding
    Unicode
  • Safety class
    III
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Switching frequency
    0,25 Hz
  • Assured release distance Sar
    max.65 mm
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Operating voltage DC
    24 V DC -15% ... +10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Maximum feed-in current in the connection block
    max.4000 mA
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Rated insulation voltage Ui
    75 V
  • Mechanical life
    0,1 x 10⁶
  • Installation orientation
    Door hinge DIN left
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Current consumption
    max.500 mA
  • Locking force FZh
    2000 N
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Ambient temperature
    -20 ... 55 °C
  • Connection
    7/8" Power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Guard locking principle
    Open-circuit current principle
  • Degree of protection
    IP54
  • Weight
    3,1 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 125577 on MQ Automation is $2,937.85. Order now.


About the product

Guard locking with guard lock monitoring;2 illuminated pushbuttons;including adhesive labels;Connection via 7/8&quot; and M12 plugs;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

125577 Euchner

$2,937.85

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$2,937.85

$2,937.85 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 125577 with other products

Weight

Series

Product Class

Mission time

PFHD

Diagnostic Coverage (DC)

Safety Integrity Level

Category

Performance Level

Additional feature

Switching element

Product version number

Version

Assignment diagram

Safety data protocol

Auxiliary voltage DC

Fusing

Transponder coding

Safety class

Bus data protocol

Switching frequency

Assured release distance ...

Degree of contamination (...

Operating voltage DC

Housing material

Connecting cable

Maximum feed-in current i...

EMC protection requiremen...

Rated insulation voltage ...

Mechanical life

Installation orientation

Rated impulse withstand v...

Shock and vibration resis...

Current consumption

Locking force FZh

Reaction time

Ambient temperature

Connection

Guard locking principle

Degree of protection

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Output voltage

Turn-on time

Off-state current Ir

Switching current

Type of output

Switching load

Risk time according to EN...

Solenoid duty cycle

Connection rating

Solenoid operating voltag...

Utilization category acc....

Test pulses

Test-pulse interval

Actuating force

Extension of risk time ac...

Extraction force

Overtravel

Locking force Fmax

Approach speed

Retention force

Ready delay

B10D

Operating current

Detent mechanism

Operating voltage

Selected product

125577
0 in stock
125577
Euchner

125577 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) ...

Weight6.61386 lb

SeriesSpare parts

Product ClassAccessories

Mission time20

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Diagnostic Coverage (DC)99

Safety Integrity LevelSIL 3 (EN 62061:2005)

Category4

Performance LevelPL e

Additional featureIncl. cover set ID. No. 1203...

Switching element1NO

Product version numberV3.30.10

VersionIlluminated push buttons

Assignment diagramB1

Safety data protocolProfisafe (IEC 61784-3-3)

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Fusingmin.1 A Slow blow

Transponder codingUnicode

Safety classIII

Bus data protocolProfinet (IEC 61158 type 10)

Switching frequency0,25 Hz

Assured release distance Sarmax.65 mm

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC -15% ... +10% ((R...

Housing materialReinforced plastic, die-cast...

Connecting cableProfinet I/O cable, at least...

Maximum feed-in current in the connection blockmax.4000 mA

EMC protection requirementsIn accordance with EN 61000-...

Rated insulation voltage Ui75 V

Mechanical life0,1 x 10⁶

Installation orientationDoor hinge DIN left

Rated impulse withstand voltage Uimp0,5 kV

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumptionmax.500 mA

Locking force FZh2000 N

Reaction timemax.550 ms Switch-off time...

Ambient temperature-20 ... 55 °C

Connection7/8" Power (X1 (The documen...

Guard locking principleOpen-circuit current princip...

Degree of protectionIP54

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Output voltage-

Turn-on time-

Off-state current Ir-

Switching current-

Type of output-

Switching load-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Connection rating-

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Test-pulse interval-

Actuating force-

Extension of risk time according to EN 60947-5-3 per device-

Extraction force-

Overtravel-

Locking force Fmax-

Approach speed-

Retention force-

Ready delay-

B10D-

Operating current-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Diagnostic Coverage (DC)-

Safety Integrity Level-

Category4

Performance LevelPL e

Additional featureEscape release actuated by p...

Switching element-

Product version number-

Version-

Assignment diagram-

Safety data protocol-

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Transponder coding-

Safety classIII

Bus data protocol-

Switching frequencymax.0,5 Hz

Assured release distance Sar-

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC -15% ... 15% Rev...

Housing materialDie-cast zinc

Connecting cable-

Maximum feed-in current in the connection block-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui50 V

Mechanical life1 x 10⁶

Installation orientationAny

Rated impulse withstand voltage Uimp0,5 kV

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumption40 mA

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Reaction time-

Ambient temperature-20 ... +55 °C

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0,8xUB ... UB V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Connection rating6 W

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Extraction force20 N

Overtravel5 mm

Locking force Fmax3900 N

Approach speedmax.20 m/min

Retention force20 N

Ready delay8 s

B10D-

Operating current-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Diagnostic Coverage (DC)-

Safety Integrity Level-

Category4

Performance LevelPL e

Additional feature-

Switching element2 pos. driven NC

Product version number-

VersionEmergency stop

Assignment diagram-

Safety data protocol-

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Transponder coding-

Safety classIII

Bus data protocol-

Switching frequencymax.0,5 Hz

Assured release distance Sar-

Degree of contamination (external, according to EN 60947-1)3

Operating voltage DC24 V DC -15% ... 15% Rev...

Housing materialFiber glass reinforced therm...

Connecting cable-

Maximum feed-in current in the connection block-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated insulation voltage Ui50 V

Mechanical life1 x 10⁶

Installation orientationDoor hinge DIN right

Rated impulse withstand voltage Uimp0,5 kV

Shock and vibration resistanceIn acc. with EN 60947-5-3

Current consumption40 mA

Locking force FZh-

Reaction time-

Ambient temperature-20 ... +55 °C

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Degree of protectionIP65 (Screwed tight plug co...

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Discrepancy timemax.10 ms In acc. with EN ...

Output voltage0 ... 1 V DC

Turn-on timemax.400 ms

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (Alternativ...

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Connection rating1 W

Solenoid operating voltage DC-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extension of risk time according to EN 60947-5-3 per device-

Extraction force20 N

Overtravel5 mm

Locking force Fmax-

Approach speedmax.20 m/min

Retention force-

Ready delaymax.1 s

B10D0,13 x 10⁶

Operating current1 ... 100 mA

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 125577?
The price of 125577 on MQ Automation is $2,937.85. Order now.

Out if stock but available for backorder.

125577 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 2 control elements, 7/8&quot; and M12 plugs

What can I help you find today?

Recommended parts