124818 Euchner Safety Accessories

124818 on MQ Automation
Euchner
  • 124818
  • 124818

Part#:124818

Alt. Part#:MGB-L1CB-PNA-R-124818

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

124818 Euchner - Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, 7/8" and M12 plugs, RC12

Product Details

  • Weight
    10.3286447 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • B10D
    (According to manufacturer’s specifications)
  • Diagnostic Coverage (DC)
    99
  • PFHD
    4.1 x 10⁻⁸
  • Product version number
    V3.30.10
  • Switching element
    1NO
  • Version
    Illuminated push buttons
  • Performance Level
    PL e
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Color
    white
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Category
    4
  • Assignment diagram
    L0
  • Fusing
    min.1 A Slow blow
  • Assured release distance Sar
    max.65 mm
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Operating voltage DC
    24 V DC -15% ... +10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Safety class
    III
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Transponder coding
    Unicode
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Guard locking principle
    Closed-circuit current principle
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Locking force FZh
    2000 N
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Current consumption
    max.500 mA
  • Connection
    M12 D-coded, screened (X3 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Switching frequency
    0,25 Hz
  • Rated insulation voltage Ui
    75 V
  • Degree of protection
    IP54
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Installation orientation
    Door hinge DIN right
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Mechanical life
    0,1 x 10⁶
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    4,05 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 124818 on MQ Automation is $4,059.07. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850, illuminated;9 illuminated pushbuttons;Operating mode selector;Connection via 7/8&quot; and M12 plugs;including terminal plug for stack light (M12, 5-pin);including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

124818 Euchner

$4,059.07

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$4,059.07

$4,059.07 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 124818 with other products

Weight

Series

Product Class

Mission time

Safety Integrity Level

B10D

Diagnostic Coverage (DC)

PFHD

Product version number

Switching element

Version

Performance Level

Safety data protocol

Color

Bus data protocol

Category

Assignment diagram

Fusing

Assured release distance ...

Connecting cable

Operating voltage DC

Safety class

Auxiliary voltage DC

Transponder coding

Degree of contamination (...

EMC protection requiremen...

Guard locking principle

Shock and vibration resis...

Rated impulse withstand v...

Locking force FZh

Maximum feed-in current i...

Current consumption

Connection

Switching frequency

Rated insulation voltage ...

Degree of protection

Reaction time

Installation orientation

Housing material

Mechanical life

Ambient temperature

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

124818
0 in stock
124818
Euchner

124818 Euchner - Evaluation module with control and bus module MGB-...-PN with 11 controls and indic...

Weight10.3286447 lb

SeriesSpare parts

Product ClassAccessories

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

B10D(According to manufacturer’s...

Diagnostic Coverage (DC)99

PFHD4.1 x 10⁻⁸

Product version numberV3.30.10

Switching element1NO

VersionIlluminated push buttons

Performance LevelPL e

Safety data protocolProfisafe (IEC 61784-3-3)

Colorwhite

Bus data protocolProfinet (IEC 61158 type 10)

Category4

Assignment diagramL0

Fusingmin.1 A Slow blow

Assured release distance Sarmax.65 mm

Connecting cableProfinet I/O cable, at least...

Operating voltage DC24 V DC -15% ... +10% ((R...

Safety classIII

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Transponder codingUnicode

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-...

Guard locking principleClosed-circuit current princ...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh2000 N

Maximum feed-in current in the connection blockmax.4000 mA

Current consumptionmax.500 mA

ConnectionM12 D-coded, screened (X3 (...

Switching frequency0,25 Hz

Rated insulation voltage Ui75 V

Degree of protectionIP54

Reaction timemax.250 ms Switch-off time...

Installation orientationDoor hinge DIN right

Housing materialReinforced plastic, die-cast...

Mechanical life0,1 x 10⁶

Ambient temperature-20 ... 55 °C

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

B10D0,13 x 10⁶

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Product version number-

Switching element2 pos. driven NC

VersionEmergency stop

Performance LevelPL e

Safety data protocol-

Color-

Bus data protocol-

Category4

Assignment diagram-

Fusing0,25 ... 8 A

Assured release distance Sar-

Connecting cable-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Auxiliary voltage DC-

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Guard locking principle-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh-

Maximum feed-in current in the connection block-

Current consumption40 mA

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Rated insulation voltage Ui50 V

Degree of protectionIP65 (Screwed tight plug co...

Reaction time-

Installation orientationDoor hinge DIN right

Housing materialFiber glass reinforced therm...

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Safety Integrity Level-

B10D-

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Product version number-

Switching element-

Version-

Performance LevelPL e

Safety data protocol-

Color-

Bus data protocol-

Category4

Assignment diagram-

Fusing0,25 ... 8 A

Assured release distance Sar-

Connecting cable-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Auxiliary voltage DC-

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Guard locking principleClosed-circuit current princ...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Rated impulse withstand voltage Uimp0,5 kV

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Maximum feed-in current in the connection block-

Current consumption40 mA

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Rated insulation voltage Ui50 V

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Reaction time-

Installation orientationAny

Housing materialDie-cast zinc

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 124818?
The price of 124818 on MQ Automation is $4,059.07. Order now.

Out if stock but available for backorder.

124818 Euchner - Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, 7/8&quot; and M12 plugs, RC12

What can I help you find today?

Recommended parts