124256 Euchner Safety Accessories

124256 on MQ Automation
Euchner
  • 124256
  • 124256
  • 124256

Part#:124256

Alt. Part#:MGB-L0-ARA-AA8A1-S1-R-124256

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

124256 Euchner - Interlocking module MGB-L0-ARA..., with 2 pushbuttons, incl. label carrier, RC18

Product Details

  • Weight
    1.9621118 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Category
    4
  • Switching element
    1NO
  • Product version number
    V4.0.0
  • Color
    Yellow
  • Version
    Illuminated push buttons
  • Assignment diagram
    L1
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.1 ms
  • Current consumption
    max.80 mA ((no load on outputs))
  • Breaking capacity
    max.0,25 W
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Power supply LED
    24 V DC
  • Switching current
    1 ... 10 mA
  • Output current
    max.50 mA
  • Output voltage
    UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Switching voltage
    UA V
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Transponder coding
    Unicode
  • Safety class
    III
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Discrepancy time
    max.10 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    30 V
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP65
  • Connection
    Plug connector RC18 (X6)
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Installation orientation
    Door hinge DIN right
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 124256 on MQ Automation is $1,090.50. Order now.


About the product

Interlocking (without guard locking);Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;With plug connector RC18;Unicode


Manufacturer warranty

124256 Euchner

$1,090.50

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,090.50

$1,090.50 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 124256 with other products

Weight

Series

Product Class

Mission time

PFHD

Performance Level

Category

Switching element

Product version number

Color

Version

Assignment diagram

Test-pulse interval

Test pulses

Current consumption

Breaking capacity

Operating voltage DC

Power supply LED

Switching current

Output current

Output voltage

Switching voltage

Type of output

Transponder coding

Safety class

Risk time according to EN...

Degree of contamination (...

Discrepancy time

Rated impulse withstand v...

Rated insulation voltage ...

Utilization category acc....

Ambient temperature

Degree of protection

Connection

Mechanical life

Switching frequency

Installation orientation

Housing material

B10D

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Operating distance

Rated conditional short-c...

Extension of risk time ac...

Tightening torque

Mounting distance

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

124256
0 in stock
124256
Euchner

124256 Euchner - Interlocking module MGB-L0-ARA..., with 2 pushbuttons, incl. label carrier, RC18

Weight1.9621118 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Category4

Switching element1NO

Product version numberV4.0.0

ColorYellow

VersionIlluminated push buttons

Assignment diagramL1

Test-pulse intervalmin.100 ms

Test pulsesmax.1 ms

Current consumptionmax.80 mA ((no load on outp...

Breaking capacitymax.0,25 W

Operating voltage DC24 V DC -15% ... 10% ((Re...

Power supply LED24 V DC

Switching current1 ... 10 mA

Output currentmax.50 mA

Output voltageUA-2V ... UA V DC (Value at...

Switching voltageU<sub>A</sub> V

Type of outputSemiconductor outputs, p-swi...

Transponder codingUnicode

Safety classIII

Risk time according to EN 60947-5-3max.350 ms

Degree of contamination (external, according to EN 60947-1)3

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui30 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Ambient temperature-20 ... 55 °C

Degree of protectionIP65

ConnectionPlug connector RC18 (X6)

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Installation orientationDoor hinge DIN right

Housing materialReinforced plastic; die-cast...

B10D-

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Switching element2 pos. driven NC

Product version number-

Color-

VersionEmergency stop

Assignment diagram-

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Current consumption40 mA

Breaking capacity-

Operating voltage DC24 V DC -15% ... 15% Rev...

Power supply LED-

Switching current1 ... 150 mA

Output current-

Output voltage0 ... 1 V DC

Switching voltage-

Type of output2 semiconductor outputs, p-s...

Transponder coding-

Safety classIII

Risk time according to EN 60947-5-3-

Degree of contamination (external, according to EN 60947-1)3

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Connection2 plug connectors M12, 5-pin

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Installation orientationDoor hinge DIN right

Housing materialFiber glass reinforced therm...

B10D0,13 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

Operating distance-

Rated conditional short-circuit current-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Mounting distance-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Mission time20

PFHD1.9 x 10⁻⁹

Performance LevelPL e

Category4

Switching element-

Product version number-

Color-

Version-

Assignment diagram-

Test-pulse intervalmin.140 ms

Test pulsesmax.1 ms (Applies for a loa...

Current consumptionmax.50 mA (Without taking i...

Breaking capacity-

Operating voltage DC24 V DC 15% ... 15% Regu...

Power supply LED-

Switching currentmax.50 mA

Output current-

Output voltage0,8 x UB ... UB V DC

Switching voltage-

Type of outputp-switching, short circuit-p...

Transponder coding-

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Degree of contamination (external, according to EN 60947-1)3

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Ambient temperature-

Degree of protectionIP67

ConnectionConnection cable PUR, length...

Mechanical life-

Switching frequencymax.1 Hz

Installation orientationAny

Housing materialPlastic, PBT

B10D-

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R≤ 10

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating-

Fusing0,25 ... 8 A

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speed-

Ready delay10 s

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Rated conditional short-circuit current100 A

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Mounting distancemin.120 mm

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 124256?
The price of 124256 on MQ Automation is $1,090.50. Order now.

Out if stock but available for backorder.

124256 Euchner - Interlocking module MGB-L0-ARA..., with 2 pushbuttons, incl. label carrier, RC18

What can I help you find today?

Recommended parts