124128 Euchner - Interlocking module and bus module MGB-L0...-PN with 2 control elements, 7/8" and M12 plugs

Product Details

  • Weight
    7.70735152 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Diagnostic Coverage (DC)
    99
  • Category
    4
  • Performance Level
    PL e
  • Product version number
    V3.30.10
  • Additional feature
    Incl. cover set ID. No. 120344
  • Switching element
    1NO
  • Version
    Illuminated push buttons
  • Assignment diagram
    B1
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Fusing
    min.1 A Slow blow
  • Operating voltage DC
    24 V DC -15% ... +10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Transponder coding
    Unicode
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Safety class
    III
  • Current consumption
    max.500 mA
  • Rated insulation voltage Ui
    75 V
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Connection
    7/8" Power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Weight
    3,1 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Reaction time
    max.250 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Mechanical life
    0,1 x 10⁶
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP54
  • Installation orientation
    Door hinge DIN left

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 124128 on MQ Automation is $2,797.64. Order now.


About the product

Interlocking (without guard locking);Emergency stop according to ISO 13850, illuminated;2 illuminated pushbuttons;including adhesive labels;Connection via 7/8&quot; and M12 plugs;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

124128 Euchner

$2,797.64

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$2,797.64

$2,797.64 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 124128 with other products

Weight

Series

Product Class

B10D

Mission time

Safety Integrity Level

PFHD

Diagnostic Coverage (DC)

Category

Performance Level

Product version number

Additional feature

Switching element

Version

Assignment diagram

Safety data protocol

Bus data protocol

Assured release distance ...

Auxiliary voltage DC

Fusing

Operating voltage DC

EMC protection requiremen...

Degree of contamination (...

Transponder coding

Connecting cable

Safety class

Current consumption

Rated insulation voltage ...

Rated impulse withstand v...

Maximum feed-in current i...

Connection

Shock and vibration resis...

Reaction time

Housing material

Ambient temperature

Mechanical life

Switching frequency

Degree of protection

Installation orientation

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Locking force FZh

Guard locking principle

Selected product

124128
0 in stock
124128
Euchner

124128 Euchner - Interlocking module and bus module MGB-L0...-PN with 2 control elements, 7/8&quot; ...

Weight7.70735152 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Diagnostic Coverage (DC)99

Category4

Performance LevelPL e

Product version numberV3.30.10

Additional featureIncl. cover set ID. No. 1203...

Switching element1NO

VersionIlluminated push buttons

Assignment diagramB1

Safety data protocolProfisafe (IEC 61784-3-3)

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Fusingmin.1 A Slow blow

Operating voltage DC24 V DC -15% ... +10% ((R...

EMC protection requirementsIn accordance with EN 61000-...

Degree of contamination (external, according to EN 60947-1)3

Transponder codingUnicode

Connecting cableProfinet I/O cable, at least...

Safety classIII

Current consumptionmax.500 mA

Rated insulation voltage Ui75 V

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection blockmax.4000 mA

Connection7/8" Power (X1 (The documen...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction timemax.250 ms Switch-off time...

Housing materialReinforced plastic, die-cast...

Ambient temperature-20 ... 55 °C

Mechanical life0,1 x 10⁶

Switching frequency0,25 Hz

Degree of protectionIP54

Installation orientationDoor hinge DIN left

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

Safety Integrity Level-

PFHD4.1 x 10 ⁻⁹

Diagnostic Coverage (DC)-

Category4

Performance LevelPL e

Product version number-

Additional feature-

Switching element2 pos. driven NC

VersionEmergency stop

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Connecting cable-

Safety classIII

Current consumption40 mA

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection block-

Connection2 plug connectors M12, 5-pin

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction time-

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

Locking force FZh-

Guard locking principle-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Mission time20 y

Safety Integrity Level-

PFHD4.1 x 10 ⁻⁹

Diagnostic Coverage (DC)-

Category4

Performance LevelPL e

Product version number-

Additional featureEscape release actuated by p...

Switching element-

Version-

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Auxiliary voltage DC-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Transponder coding-

Connecting cable-

Safety classIII

Current consumption40 mA

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Maximum feed-in current in the connection block-

Connection2 plug connectors M12, 5 and...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction time-

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Mechanical life1 x 10⁶

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 124128?
The price of 124128 on MQ Automation is $2,797.64. Order now.

Out if stock but available for backorder.

124128 Euchner - Interlocking module and bus module MGB-L0...-PN with 2 control elements, 7/8&quot; and M12 plugs

What can I help you find today?

Recommended parts