  • Weight
    0.3969 lb
  • PFHD
    4.5 x 10⁻⁹
  • Mission time
    20
  • Category
    4
  • Performance Level
    PL e
  • Turn-on time
    max.300 ms
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Risk time according to EN 60947-5-3
    max.260 ms
  • ASi slave type
    EA code: 0
  • ASi data in
    D0 (Influenced by key)
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    2
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Rated insulation voltage Ui
    300 V
  • ASi operating current
    max.50 mA
  • Housing material
    PA6-GF30 black
  • Mounting cut-out
    33x68 mm
  • Ambient temperature
    -10 ... +65 °C
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Weight
    0,13 kg
  • Installation orientation
    On the front
  • ASi voltage
    19 ... 31,6 V
  • Connection
    Screw terminal 2-pole
  • Tightening torque
    0,25 ... 0,35 Nm
  • Degree of protection
    IP65/IP67 (On installation in flat metal plate, thickness = 2mm)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 123592 on MQ Automation is $850.49. Order now.


Manufacturer warranty

123592 Euchner

$850.49

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$850.49

$850.49 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 123592 with other products

Weight

PFHD

Mission time

Category

Performance Level

Turn-on time

For the approval acc. to ...

Risk time according to EN...

ASi slave type

ASi data in

Safety class

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

ASi operating current

Housing material

Mounting cut-out

Ambient temperature

Shock and vibration resis...

Installation orientation

ASi voltage

Connection

Tightening torque

Degree of protection

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

Additional feature

Repeat accuracy R

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Utilization category acc....

Test pulses

Switching current

Output voltage

Type of output

EMC protection requiremen...

Fusing

Operating voltage DC

Switching frequency

Extension of risk time ac...

Current consumption

Ready delay

Mounting method

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Material

Static bending radius

Selected product

123592
0 in stock
123592
Euchner

123592 Euchner - KEY ADAPTER CKS

Weight0.3969 lb

PFHD4.5 x 10⁻⁹

Mission time20

Category4

Performance LevelPL e

Turn-on timemax.300 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Risk time according to EN 60947-5-3max.260 ms

ASi slave typeEA code: 0

ASi data inD0 (Influenced by key)

Safety classIII

Degree of contamination (external, according to EN 60947-1)2

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

ASi operating currentmax.50 mA

Housing materialPA6-GF30 black

Mounting cut-out33x68 mm

Ambient temperature-10 ... +65 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

Installation orientationOn the front

ASi voltage19 ... 31,6 V

ConnectionScrew terminal 2-pole

Tightening torque0,25 ... 0,35 Nm

Degree of protectionIP65/IP67 (On installation ...

Series-

Product Class-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Additional feature-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Switching current-

Output voltage-

Type of output-

EMC protection requirements-

Fusing-

Operating voltage DC-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Ready delay-

Mounting method-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

PFHD4.1 x 10⁻⁹

Mission time20

Category4

Performance LevelPL e

Turn-on timemax.400 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Risk time according to EN 60947-5-3max.260 ms

ASi slave type-

ASi data in-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

ASi operating current-

Housing materialPlastic, PBT

Mounting cut-out-

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Installation orientationAny

ASi voltage-

ConnectionConnection cable PUR, length...

Tightening torquemax.0,8 Nm

Degree of protectionIP67

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Additional featureRubber support included

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Switching currentmax.50 mA

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-swit...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.35 mA (Without taking i...

Ready delay10 s

Mounting methodSurface mounting on metal

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

MaterialNBR 80 ±5 Shore

Static bending radius5 x cable diameter

105602
3 in stock
105602
Euchner

105602 Euchner - Non-contact safety switch CES-AP-CL2-..., flying lead, PVC

Weight0.52029032 lb

PFHD1.8 x 10⁻⁹

Mission time20

Category4

Performance LevelPL e

Turn-on timemax.300 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Risk time according to EN 60947-5-3max.260 ms

ASi slave type-

ASi data in-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

ASi operating current-

Housing materialPlastic, PBT

Mounting cut-out-

Ambient temperature-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Installation orientationAny

ASi voltage-

Connectionconnection cable PVC, length...

Tightening torquemax.1 Nm

Degree of protectionIP67, IP69K

SeriesCES-AP

Product ClassSafety System

Assured operating distance Saomin.14 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Additional feature-

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.100 ms

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Test pulsesmax.0,3 ms (Applies for a l...

Switching currentmax.50 mA

Output voltage0,8 x UB ... UB V DC

Type of outputp-switching, short circuit-p...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Operating voltage DC24 V DC 15% ... 15% Regu...

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per device-

Current consumptionmax.30 mA (Without taking i...

Ready delay0,5 s

Mounting methodSurface mounting on metal

Mounting distancemin.400 mm

Cable ambient temperature (static)-40 ... 65 °C

Cable ambient temperature (dynamic)0 ... 65 °C

Dynamic bending radius10 x cable diameter

Material-

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 123592?
The price of 123592 on MQ Automation is $850.49. Order now.

Out if stock but available for backorder.

123592 Euchner - KEY ADAPTER CKS

What can I help you find today?

Recommended parts