123361 Euchner Safety Switches

123361 on MQ Automation
Euchner
  • 123361
  • 123361
  • 123361

Part#:123361

Alt. Part#:CTP-L2-AR-M-HA-AZ-SAB-123361

Manufacturer:Euchner

Category:Safety Switches

Product Lifecycle:Active

Only 2 left in stock. Order Now!

Mar 15, 2025

Product description

123361 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12

Product Details

  • Weight
    1.322772 lb
  • Series
    CTP-AR
  • Product Class
    Safety System
  • Repeat accuracy R
    10 %
  • Category
    4
  • Performance Level
    PL e
  • PFHD
    4.1 x 10 ⁻⁹
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Mission time
    20 y
  • Discrepancy time
    max.10 ms In acc. with EN IEC 60947-5-3
  • Turn-on time
    max.400 ms
  • Output voltage
    0,8xUB ... UB V DC
  • Off-state current Ir
    max.0,25 mA
  • Switching current
    1 ... 50 mA
  • Switching load
    24V DC, class 2 (Alternatively see operating instructions)
  • Safety class
    III
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Type of output
    p-switching, short circuit-proof
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Utilization category acc. to EN 60947-5-2
    24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Rated insulation voltage Ui
    50 V
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Connection rating
    6 W
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Fusing
    0,25 ... 8 A
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    40 mA
  • Overtravel
    5 mm
  • Test-pulse interval
    min.140 ms
  • Extraction force
    20 N
  • Locking force Fmax
    3900 N
  • Test pulses
    max.1,0 ms (Applies for a load with C ≤ 30nF and R ≤ 20kOhm)
  • Actuating force
    10 N
  • Locking force FZh
    3000 N (Fzh = Fmax/1.3 Depending on the actuator used)
  • Guard locking principle
    Open-circuit current principle
  • Retention force
    20 N
  • Approach speed
    max.20 m/min
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Installation orientation
    Any
  • Ambient temperature
    -20 ... +55 °C
  • Switching frequency
    max.0,5 Hz
  • Mechanical life
    1 x 10⁶
  • Weight
    0,42 kg
  • Housing material
    Die-cast zinc
  • Ready delay
    8 s
  • Degree of protection
    IP67/IP69/IP69K (Screwed tight plug connector/mating component)
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 123361 on MQ Automation is $733.06. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Up to category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Door monitoring output;Approach directions A, B and C (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

123361 Euchner

$733.06

Your price can be lower.
Log in or Create account to check your discount

Stock:

2

Select Qty:

$733.06

$733.06 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 123361 with other products

Weight

Series

Product Class

Repeat accuracy R

Category

Performance Level

PFHD

For the approval acc. to ...

Mission time

Discrepancy time

Turn-on time

Output voltage

Off-state current Ir

Switching current

Switching load

Safety class

Risk time according to EN...

Type of output

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Utilization category acc....

Rated insulation voltage ...

Rated impulse withstand v...

Solenoid operating voltag...

Connection rating

Extension of risk time ac...

Fusing

Operating voltage DC

Current consumption

Overtravel

Test-pulse interval

Extraction force

Locking force Fmax

Test pulses

Actuating force

Locking force FZh

Guard locking principle

Retention force

Approach speed

Connection

Installation orientation

Ambient temperature

Switching frequency

Mechanical life

Housing material

Ready delay

Degree of protection

Shock and vibration resis...

Additional feature

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

123361
2 in stock
123361
Euchner

123361 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12

Weight1.322772 lb

SeriesCTP-AR

Product ClassSafety System

Repeat accuracy R10 %

Category4

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Mission time20 y

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Output voltage0,8xUB ... UB V DC

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Connection rating6 W

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Locking force Fmax3900 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleOpen-circuit current princip...

Retention force20 N

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Housing materialDie-cast zinc

Ready delay8 s

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Repeat accuracy R10 %

Category4

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Mission time20 y

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Output voltage0,8xUB ... UB V DC

Off-state current Irmax.0,25 mA

Switching current1 ... 50 mA

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Connection rating6 W

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Locking force Fmax3900 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Guard locking principleClosed-circuit current princ...

Retention force20 N

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Installation orientationAny

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Housing materialDie-cast zinc

Ready delay8 s

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional featureEscape release actuated by p...

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Repeat accuracy R10 %

Category4

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Mission time20 y

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Output voltage0 ... 1 V DC

Off-state current Irmax.0,25 mA

Switching current1 ... 150 mA

Switching load24V DC, class 2 (Alternativ...

Safety classIII

Risk time according to EN 60947-5-3-

Type of output2 semiconductor outputs, p-s...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Rated impulse withstand voltage Uimp0,5 kV

Solenoid operating voltage DC-

Connection rating1 W

Extension of risk time according to EN 60947-5-3 per device-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Current consumption40 mA

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Locking force Fmax-

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Locking force FZh-

Guard locking principle-

Retention force-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Installation orientationDoor hinge DIN right

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Housing materialFiber glass reinforced therm...

Ready delaymax.1 s

Degree of protectionIP65 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 123361?
The price of 123361 on MQ Automation is $733.06. Order now.

Out if stock but available for backorder.

123361 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12

Similar products from: Safety Switches

What can I help you find today?

Recommended parts