122706 Euchner - Expansion module MSC-CE

Product Details

  • Weight
    0.5732012 lb
  • Series
    MSC
  • Product Class
    safety relay
  • Output current
    max.100 mA (at 24 VDC per output)
  • Connection cross-section
    0,5 ... 2,5 mm² (Screw terminal)
  • Operating voltage DC
    24 V DC -20% ... +20% PELV (Acc. to EN 60204-1)
  • Power dissipation
    max.3 W
  • Number of monitoring outputs
    8 (Programmable digital output – PNP active high)
  • Connection
    Plug-in screw terminal (Terminals not included)
  • Degree of protection
    IP20
  • Ambient temperature
    -10 ... +55 °C
  • Mounting method
    Mounting rail 35mm (Acc. to EN 60715)
  • Material
    Polyamide
  • Atmospheric humidity
    10 ... 95 % rH
  • Storage temperature
    -20 ... +85 °C
  • Dimensions
    108 x 22.5 x 114.5 (Including screw terminals)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 122706 on MQ Automation is $383.19. Order now.


About the product

Output expansion;8 monitoring outputs;Compact housing with width of only 22.5mm;Simple diagnostics via LED displays


Manufacturer warranty

122706 Euchner

$383.19

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$383.19

$383.19 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 122706 with other products

Weight

Series

Product Class

Output current

Connection cross-section

Operating voltage DC

Power dissipation

Number of monitoring outp...

Connection

Degree of protection

Ambient temperature

Mounting method

Material

Atmospheric humidity

Storage temperature

Dimensions

Additional feature

Data interface

Utilization category acc....

Current consumption

Utilization category acc....

Switching current

LED indicator

Switching voltage

Number of read heads

Housing material

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

Mission time

PFHD

For the approval acc. to ...

Performance Level

Repeat accuracy R

Category

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Test pulses

Output voltage

Type of output

Turn-on time

Risk time according to EN...

Safety class

EMC protection requiremen...

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Fusing

Switching frequency

Extension of risk time ac...

Ready delay

Tightening torque

Installation orientation

Shock and vibration resis...

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Static bending radius

Selected product

122706
0 in stock
122706
Euchner

122706 Euchner - Expansion module MSC-CE

Weight0.5732012 lb

SeriesMSC

Product Classsafety relay

Output currentmax.100 mA (at 24 VDC per o...

Connection cross-section0,5 ... 2,5 mm² (Screw term...

Operating voltage DC24 V DC -20% ... +20% PE...

Power dissipationmax.3 W

Number of monitoring outputs8 (Programmable digital ou...

ConnectionPlug-in screw terminal (Ter...

Degree of protectionIP20

Ambient temperature-10 ... +55 °C

Mounting methodMounting rail 35mm (Acc. to...

MaterialPolyamide

Atmospheric humidity10 ... 95 % rH

Storage temperature-20 ... +85 °C

Dimensions108 x 22.5 x 114.5 (Includi...

Additional feature-

Data interface-

Utilization category acc. to EN 60947-5-1-

Current consumption-

Utilization category acc. to EN 60947-5-2-

Switching current-

LED indicator-

Switching voltage-

Number of read heads-

Housing material-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Mission time-

PFHD-

For the approval acc. to UL the following applies-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Test pulses-

Output voltage-

Type of output-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Ready delay-

Tightening torque-

Installation orientation-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

113645
1 in stock
113645
Euchner

113645 Euchner - Interface adapter EKS Light FSA modular (supports all operating states)

Weight0.46517482 lb

SeriesEKS Light

Product ClassElectronic-Key-System

Output current-

Connection cross-section0,14 ... 2,5 mm²

Operating voltage DC9 ... 24 ... 28 V DC (For u...

Power dissipation-

Number of monitoring outputs-

ConnectionPlug-in screw terminal

Degree of protection-

Ambient temperature0 ... 55 °C

Mounting methodMounting rail 35mm according...

Material-

Atmospheric humidity-

Storage temperature-

Dimensions-

Additional feature35 Resistance in switched-...

Data interface4-bit parallel plus strobe, ...

Utilization category acc. to EN 60947-5-124V 50mA

Current consumptionmax.70 mA

Utilization category acc. to EN 60947-5-224V 50mA

Switching current1 ... 10 ... 50 mA High si...

LED indicatorOperational

Switching voltageU<sub>B</sub>-2 ... U<sub>B<...

Number of read headsmax.1

Housing materialPA6.6 gray

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Mission time-

PFHD-

For the approval acc. to UL the following applies-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Test pulses-

Output voltage-

Type of output-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Ready delay-

Tightening torque-

Installation orientation-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

SeriesCES-AR

Product ClassSafety System

Output current-

Connection cross-section-

Operating voltage DC24 V DC 15% ... 15% Regu...

Power dissipation-

Number of monitoring outputs-

ConnectionConnection cable PUR, length...

Degree of protectionIP67

Ambient temperature-

Mounting methodSurface mounting on metal

MaterialNBR 80 ±5 Shore

Atmospheric humidity-

Storage temperature-

Dimensions-

Additional featureRubber support included

Data interface-

Utilization category acc. to EN 60947-5-1-

Current consumptionmax.35 mA (Without taking i...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching currentmax.50 mA

LED indicator-

Switching voltage-

Number of read heads-

Housing materialPlastic, PBT

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Mission time20

PFHD4.1 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Performance LevelPL e

Repeat accuracy R≤ 10

Category4

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-swit...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 122706?
The price of 122706 on MQ Automation is $383.19. Order now.

Out if stock but available for backorder.

122706 Euchner - Expansion module MSC-CE

What can I help you find today?

Recommended parts