122705 Euchner Safety Relays

122705 on MQ Automation
Euchner

Part#:122705

Alt. Part#:MSC-CE-AH-FO4SO8-122705

Manufacturer:Euchner

Category:Safety Relays

Product Lifecycle:Active

Product description

122705 Euchner - EXPANSION MODULE MSC

Product Details

  • Weight
    0.469665 lb
  • Connection cross-section
    0,5 ... 2,5 mm² (Screw terminal)
  • Operating voltage DC
    24 V DC -20% ... +20% PELV (Acc. to EN 60204-1)
  • PFHD
    9.28 E-09 1/h (Acc. to IEC 61508:2010)
  • Current
    max.2 A per channel (On the use of the module AH-FO4SO8 with output current > 500 mA, the module must be separated from the neighboring modules by the connection of an MSC plug connector in between.)
  • Power dissipation
    max.4 W
  • Number of inputs
    4
  • Degree of protection
    IP20
  • Number of safety outputs
    4 with single channel (or 2 with dual channels), cat. 4 (Safety outputs with fixed PNP active high state)
  • Mounting method
    Mounting rail 35mm (Acc. to EN 60715)
  • Number of monitoring outputs
    8
  • Storage temperature
    -20 ... +85 °C
  • Atmospheric humidity
    10 ... 95 % rH
  • Connection
    Plug-in screw terminal (Terminals not included)
  • Dimensions
    108 x 22.5 x 114.5 (Including screw terminals)
  • Ambient temperature
    -10 ... +55 °C
  • Material
    Polyamide

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 122705 on MQ Automation is $586.04. Order now.


Manufacturer warranty

122705 Euchner

$586.04

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$586.04

$586.04 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 122705 with other products

Weight

Connection cross-section

Operating voltage DC

PFHD

Current

Power dissipation

Number of inputs

Degree of protection

Number of safety outputs

Mounting method

Number of monitoring outp...

Storage temperature

Atmospheric humidity

Connection

Dimensions

Ambient temperature

Material

Series

Product Class

Assured operating distanc...

Switching hysteresis

Assured release distance ...

Operating distance

Mission time

For the approval acc. to ...

Additional feature

Performance Level

Repeat accuracy R

Category

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test-pulse interval

Utilization category acc....

Test pulses

Switching current

Output voltage

Type of output

Turn-on time

Risk time according to EN...

Safety class

EMC protection requiremen...

Degree of contamination (...

Rated impulse withstand v...

Rated insulation voltage ...

Fusing

Switching frequency

Extension of risk time ac...

Current consumption

Ready delay

Tightening torque

Installation orientation

Shock and vibration resis...

Mounting distance

Cable ambient temperature...

Cable ambient temperature...

Dynamic bending radius

Housing material

Static bending radius

Selected product

122705
0 in stock
122705
Euchner

122705 Euchner - EXPANSION MODULE MSC

Weight0.469665 lb

Connection cross-section0,5 ... 2,5 mm² (Screw term...

Operating voltage DC24 V DC -20% ... +20% PE...

PFHD9.28 E-09 1/h (Acc. to IEC ...

Currentmax.2 A per channel (On t...

Power dissipationmax.4 W

Number of inputs4

Degree of protectionIP20

Number of safety outputs4 with single channel (or...

Mounting methodMounting rail 35mm (Acc. to...

Number of monitoring outputs8

Storage temperature-20 ... +85 °C

Atmospheric humidity10 ... 95 % rH

ConnectionPlug-in screw terminal (Ter...

Dimensions108 x 22.5 x 114.5 (Includi...

Ambient temperature-10 ... +55 °C

MaterialPolyamide

Series-

Product Class-

Assured operating distance Sao-

Switching hysteresis-

Assured release distance Sar-

Operating distance-

Mission time-

For the approval acc. to UL the following applies-

Additional feature-

Performance Level-

Repeat accuracy R-

Category-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test-pulse interval-

Utilization category acc. to EN 60947-5-2-

Test pulses-

Switching current-

Output voltage-

Type of output-

Turn-on time-

Risk time according to EN 60947-5-3-

Safety class-

EMC protection requirements-

Degree of contamination (external, according to EN 60947-1)-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Fusing-

Switching frequency-

Extension of risk time according to EN 60947-5-3 per device-

Current consumption-

Ready delay-

Tightening torque-

Installation orientation-

Shock and vibration resistance-

Mounting distance-

Cable ambient temperature (static)-

Cable ambient temperature (dynamic)-

Dynamic bending radius-

Housing material-

Static bending radius-

119473
23 in stock
119473
Euchner

119473 Euchner - Non-contact safety switches CES-I-AR-.-C04-…, M12

Weight0.23589434 lb

Connection cross-section-

Operating voltage DC24 V DC 15% ... 15% Regu...

PFHD4.1 x 10⁻⁹

Current-

Power dissipation-

Number of inputs-

Degree of protectionIP67

Number of safety outputs-

Mounting methodSurface mounting on metal

Number of monitoring outputs-

Storage temperature-

Atmospheric humidity-

ConnectionConnection cable PUR, length...

Dimensions-

Ambient temperature-

MaterialNBR 80 ±5 Shore

SeriesCES-AR

Product ClassSafety System

Assured operating distance Sao6

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance11 mm

Mission time20

For the approval acc. to UL the following appliesOperation only with UL class...

Additional featureRubber support included

Performance LevelPL e

Repeat accuracy R≤ 10

Category4

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1,0 ms (Applies for a l...

Switching currentmax.50 mA

Output voltage0,8 x UB ... UB V DC

Type of outputSemiconductor output, p-swit...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui300 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.35 mA (Without taking i...

Ready delay10 s

Tightening torquemax.0,8 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.80 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

Connection cross-section-

Operating voltage DC24 V DC 15% ... 15% Regu...

PFHD1.9 x 10⁻⁹

Current-

Power dissipation-

Number of inputs-

Degree of protectionIP67

Number of safety outputs-

Mounting methodSurface mounting on metal

Number of monitoring outputs-

Storage temperature-

Atmospheric humidity-

ConnectionConnection cable PUR, length...

Dimensions-

Ambient temperature-

Material-

SeriesCES-AR

Product ClassSafety System

Assured operating distance Saomin.14 mm

Switching hysteresismin.1 mm

Assured release distance Sarmax.60 mm

Operating distance19 mm

Mission time20

For the approval acc. to UL the following appliesOperation only with UL class...

Additional feature-

Performance LevelPL e

Repeat accuracy R≤ 10

Category4

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test-pulse intervalmin.140 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Test pulsesmax.1 ms (Applies for a loa...

Switching currentmax.50 mA

Output voltage0,8 x UB ... UB V DC

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Switching frequencymax.1 Hz

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Current consumptionmax.50 mA (Without taking i...

Ready delay10 s

Tightening torquemax.1 Nm

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Mounting distancemin.120 mm

Cable ambient temperature (static)-25 ... 65 °C

Cable ambient temperature (dynamic)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

Housing materialPlastic, PBT

Static bending radius5 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 122705?
The price of 122705 on MQ Automation is $586.04. Order now.

Out if stock but available for backorder.

122705 Euchner - EXPANSION MODULE MSC

What can I help you find today?

Recommended parts