121406 Euchner Safety Accessories

121406 on MQ Automation
Euchner
  • 121406
  • 121406
  • 121406

Part#:121406

Alt. Part#:MGB-L1-ARA-AP7A1-M-L-121406

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

121406 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton, emergency stop, selector switch

Product Details

  • Weight
    2.30823714 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Performance Level
    PL e
  • B10D
    0,13 x 10⁶
  • PFHD
    3.7 x 10⁻⁹
  • Mission time
    20 y
  • Category
    4
  • Product version number
    V4.0.0
  • Additional feature
    Incl. cover set ID. No. 120344
  • Version
    Emergency stop
  • Special features
    With auxiliary contact
  • Switching element
    2 pos. driven NC + 1NO
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Assignment diagram
    L1
  • Current consumption
    max.80 mA ((no load on outputs))
  • Power supply LED
    24 V DC
  • Switching voltage
    UA V
  • Test pulses
    max.1 ms
  • Switching current
    1 ... 10 mA
  • Breaking capacity
    max.0,25 W
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test-pulse interval
    min.100 ms
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Transponder coding
    Unicode
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Discrepancy time
    max.10 ms
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Safety class
    III
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Connection cross-section
    0,13 ... 1,5 mm² ((AWG 24 ... AWG 16))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    30 V
  • Locking force FZh
    2000 N
  • Installation orientation
    Door hinge DIN left
  • Switching frequency
    0,25 Hz
  • Mechanical life
    0,1 x 10⁶
  • Connection
    Cable entries M20x1.5
  • Guard locking principle
    Closed-circuit current principle
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP65
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 121406 on MQ Automation is $1,419.38. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated);With lens set, 6 pcs.;Selector switch (form V, 90°);With cable entry;Unicode


Manufacturer warranty

121406 Euchner

$1,419.38

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,419.38

$1,419.38 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 121406 with other products

Weight

Series

Product Class

Performance Level

B10D

PFHD

Mission time

Category

Product version number

Additional feature

Version

Special features

Switching element

Operating voltage DC

Assignment diagram

Current consumption

Power supply LED

Switching voltage

Test pulses

Switching current

Breaking capacity

Output current

Type of output

Test-pulse interval

Output voltage

Transponder coding

Risk time according to EN...

Discrepancy time

Rated impulse withstand v...

Safety class

Utilization category acc....

Connection cross-section

Degree of contamination (...

Rated insulation voltage ...

Locking force FZh

Installation orientation

Switching frequency

Mechanical life

Connection

Guard locking principle

Housing material

Ambient temperature

Degree of protection

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

121406
0 in stock
121406
Euchner

121406 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton, em...

Weight2.30823714 lb

SeriesSpare parts

Product ClassAccessories

Performance LevelPL e

B10D0,13 x 10⁶

PFHD3.7 x 10⁻⁹

Mission time20 y

Category4

Product version numberV4.0.0

Additional featureIncl. cover set ID. No. 1203...

VersionEmergency stop

Special featuresWith auxiliary contact

Switching element2 pos. driven NC + 1NO

Operating voltage DC24 V DC -15% ... 10% ((Re...

Assignment diagramL1

Current consumptionmax.80 mA ((no load on outp...

Power supply LED24 V DC

Switching voltageU<sub>A</sub> V

Test pulsesmax.1 ms

Switching current1 ... 10 mA

Breaking capacitymax.0,25 W

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-swi...

Test-pulse intervalmin.100 ms

Output voltageUB-2V ... UB V DC (Value at...

Transponder codingUnicode

Risk time according to EN 60947-5-3max.350 ms

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Safety classIII

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Connection cross-section0,13 ... 1,5 mm² ((AWG 24 ....

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui30 V

Locking force FZh2000 N

Installation orientationDoor hinge DIN left

Switching frequency0,25 Hz

Mechanical life0,1 x 10⁶

ConnectionCable entries M20x1.5

Guard locking principleClosed-circuit current princ...

Housing materialReinforced plastic; die-cast...

Ambient temperature-20 ... 55 °C

Degree of protectionIP65

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Performance LevelPL e

B10D0,13 x 10⁶

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Category4

Product version number-

Additional feature-

VersionEmergency stop

Special features-

Switching element2 pos. driven NC

Operating voltage DC24 V DC -15% ... 15% Rev...

Assignment diagram-

Current consumption40 mA

Power supply LED-

Switching voltage-

Test pulsesmax.0,3 ms (Applies for a l...

Switching current1 ... 150 mA

Breaking capacity-

Output current-

Type of output2 semiconductor outputs, p-s...

Test-pulse intervalmin.100 ms

Output voltage0 ... 1 V DC

Transponder coding-

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Locking force FZh-

Installation orientationDoor hinge DIN right

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Performance LevelPL e

B10D-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Category4

Product version number-

Additional featureEscape release actuated by p...

Version-

Special features-

Switching element-

Operating voltage DC24 V DC -15% ... 15% Rev...

Assignment diagram-

Current consumption40 mA

Power supply LED-

Switching voltage-

Test pulsesmax.1,0 ms (Applies for a l...

Switching current1 ... 50 mA

Breaking capacity-

Output current-

Type of outputp-switching, short circuit-p...

Test-pulse intervalmin.140 ms

Output voltage0,8xUB ... UB V DC

Transponder coding-

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Rated impulse withstand voltage Uimp0,5 kV

Safety classIII

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Connection cross-section-

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Installation orientationAny

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 121406?
The price of 121406 on MQ Automation is $1,419.38. Order now.

Out if stock but available for backorder.

121406 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton, emergency stop, selector switch

What can I help you find today?

Recommended parts