120824 Euchner Electronic Components

120824 on MQ Automation
Euchner

Part#:120824

Manufacturer:Euchner

Category:Electronic Components

Product Lifecycle:Active

Product description

Safety system ESL-IH-AR... , plug connector M12

Product Details

  • Mission time
    20 y
  • Performance Level
    PL e
  • Category
    4
  • PFHD
    1.9 x 10⁻⁹
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Assured release distance Sar
    max.0 mm (For the calculation of safety parameters an s_ar of 0 mm in the door opening direction can be assumed.)
  • Output voltage
    0,8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
  • Switching current
    max.50 mA
  • Type of output
    p-switching, short circuit-proof
  • Switching load
    DC 24 V, class 2
  • Transponder coding
    Unicode
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Switching delay from state change
    max.400 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs after pulling the handle module.)
  • Safety class
    III
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Discrepancy time
    10 ms (Maximum time difference between the switching points on the safety outputs FO1A and FO1B)
  • Rated impulse withstand voltage Uimp
    0,8 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated insulation voltage Ui
    75 V
  • Fusing
    0,25 ... 8 A
  • Utilization category acc. to EN 60947-5-2
    DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Current consumption
    max.40 mA
  • Rated conditional short-circuit current
    100 A
  • Operating voltage
    24 V -15 % ... 15 %
  • Installation orientation
    Any
  • Degree of protection
    IP67
  • Tightening torque
    max.10 Nm
  • Ambient temperature
    -20 ... 55 °C
  • Connection
    M12 plug connector, 8-pin
  • Housing material
    Die-cast aluminum, powder coated, black
  • Mechanical life
    0,1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Switching frequency
    max.0,5 Hz
  • Weight
    0,4 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

120824 Euchner

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 120824 with other products

Mission time

Performance Level

Category

PFHD

For the approval acc. to ...

Assured release distance ...

Output voltage

Switching current

Type of output

Switching load

Transponder coding

EMC protection requiremen...

Switching delay from stat...

Safety class

Risk time according to EN...

Discrepancy time

Rated impulse withstand v...

Degree of contamination (...

Rated insulation voltage ...

Fusing

Utilization category acc....

Current consumption

Rated conditional short-c...

Operating voltage

Installation orientation

Degree of protection

Tightening torque

Ambient temperature

Connection

Housing material

Mechanical life

Shock and vibration resis...

Switching frequency

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Operating distance

Repeat accuracy R

Off-state current Ir

Test pulses

Test-pulse interval

Turn-on time

Extension of risk time ac...

Mounting distance

Operating voltage DC

Ready delay

Cable ambient temperature...

Mounting method

Static bending radius

Cable ambient temperature...

Dynamic bending radius

Selected product

120824
0 in stock
120824
Euchner

Safety system ESL-IH-AR... , plug connector M12

Mission time20 y

Performance LevelPL e

Category4

PFHD1.9 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Assured release distance Sarmax.0 mm (For the calculati...

Output voltage0,8 x UB ... UB V DC (Value...

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Switching loadDC 24 V, class 2

Transponder codingUnicode

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Switching delay from state changemax.400 ms (Corresponds to ...

Safety classIII

Risk time according to EN 60947-5-3max.400 ms

Discrepancy time10 ms (Maximum time differe...

Rated impulse withstand voltage Uimp0,8 kV

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-2DC-13 24V 150mA (Caution: o...

Current consumptionmax.40 mA

Rated conditional short-circuit current100 A

Operating voltage24 V -15 % ... 15 %

Installation orientationAny

Degree of protectionIP67

Tightening torquemax.10 Nm

Ambient temperature-20 ... 55 °C

ConnectionM12 plug connector, 8-pin

Housing materialDie-cast aluminum, powder co...

Mechanical life0,1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.0,5 Hz

Weight0,4 kg

Series-

Product Class-

Switching hysteresis-

Assured operating distance Sao-

Operating distance-

Repeat accuracy R-

Off-state current Ir-

Test pulses-

Test-pulse interval-

Turn-on time-

Extension of risk time according to EN 60947-5-3 per device-

Mounting distance-

Operating voltage DC-

Ready delay-

Cable ambient temperature (dynamic)-

Mounting method-

Static bending radius-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Mission time20

Performance LevelPL e

Category4

PFHD1.9 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Assured release distance Sarmax.60 mm

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Switching load-

Transponder coding-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Switching delay from state change-

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Current consumptionmax.50 mA (Without taking i...

Rated conditional short-circuit current100 A

Operating voltage-

Installation orientationAny

Degree of protectionIP67

Tightening torquemax.1 Nm

Ambient temperature-

ConnectionConnection cable PUR, length...

Housing materialPlastic, PBT

Mechanical life-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.1 Hz

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Operating distance19 mm

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Turn-on timemax.400 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting distancemin.120 mm

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

109052
68 in stock
109052
Euchner

109052 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Mission time20

Performance LevelPL e

Category4

PFHD1.9 x 10⁻⁹

For the approval acc. to UL the following appliesOperation only with UL class...

Assured release distance Sarmax.40 mm

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Switching load-

Transponder coding-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Switching delay from state change-

Safety classIII

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Rated insulation voltage Ui75 V

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Current consumptionmax.50 mA (Without taking i...

Rated conditional short-circuit current100 A

Operating voltage-

Installation orientationAny

Degree of protectionIP67, IP69K

Tightening torquemax.1 Nm

Ambient temperature-

Connectionconnection cable PUR, length...

Housing materialPlastic, PBT

Mechanical life-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Switching frequencymax.1 Hz

Weight1.763696 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.10 mm

Operating distance15 mm

Repeat accuracy R≤ 10

Off-state current Irmax.0,25 mA

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Turn-on timemax.400 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting distancemin.120 mm

Operating voltage DC24 V DC 15% ... 15% Regu...

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Cable ambient temperature (static)-30 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

Out if stock but available for backorder.

Safety system ESL-IH-AR... , plug connector M12

Similar products from: Electronic Components

What can I help you find today?

Recommended parts