119865 Euchner Safety Accessories

119865 on MQ Automation
Euchner
  • 119865
  • 119865

Part#:119865

Alt. Part#:CES-FD-AP-U-01-USI-119865

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

7 in stock

Mar 15, 2025

Product description

119865 Euchner - Field evaluation unit CES-FD-AP-…

Product Details

  • Weight
    0.34392072 lb
  • Series
    CES-FD
  • Product Class
    Safety System
  • Switching hysteresis
    min.0,05 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
  • Assured operating distance Sao
    min.3,4 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
  • Assured release distance Sar
    max.10 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
  • Category
    4
  • Operating distance
    5 mm (With read head CES-A-LMN-SC and actuator CES-A-BMB)
  • Mission time
    20
  • PFHD
    4.5 x 10⁻⁹
  • Performance Level
    PL e
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures
  • Repeat accuracy R
    ≤ 10
  • Discrepancy time
    max.10 ms
  • Risk time according to EN 60947-5-3
    max.260 ms
  • Utilization category acc. to EN 60947-5-2
    DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    UB-1,5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
  • Switching current
    1 ... 150 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Safety class
    III
  • Turn-on time
    max.400 ms
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Fusing
    0,25 ... 8 A
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Current consumption
    max.45 mA
  • Rated insulation voltage Ui
    75 V
  • Switching frequency
    max.1 Hz
  • Connection
    Connection cable PUR with plug connector M12 5-pin, pin 5 not used
  • Operating voltage DC
    24 V DC 15% ... 15% (The device tolerates voltage interruptions in the operating voltage, e.g. test pulses, of up to 5 ms. These voltage interruptions are also output on the safety outputs.)
  • Weight
    0,096 kg
  • Installation orientation
    Any
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Housing material
    Plastic, PBT
  • Cable ambient temperature (static)
    -20 ... 65 °C
  • Degree of protection
    IP67
  • Ready delay
    1 s
  • Tightening torque
    max.1 Nm
  • Cable ambient temperature (dynamic)
    -5 ... 65 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 119865 on MQ Automation is $425.01. Order now.


About the product

Connection of a CES/CKS read head ;Evaluation of signals in the field;Connection to the ET200s and ET200pro;Familiar EUCHNER AP interface;Unicode


This item can ship in 3-5 days!

Manufacturer warranty

119865 Euchner

$425.01

Your price can be lower.
Log in or Create account to check your discount

Stock:

7

Select Qty:

$425.01

$425.01 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 119865 with other products

Weight

Series

Product Class

Switching hysteresis

Assured operating distanc...

Assured release distance ...

Category

Operating distance

Mission time

PFHD

Performance Level

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Risk time according to EN...

Utilization category acc....

Off-state current Ir

Output voltage

Switching current

Type of output

Safety class

Turn-on time

EMC protection requiremen...

Fusing

Rated impulse withstand v...

Degree of contamination (...

Current consumption

Rated insulation voltage ...

Switching frequency

Connection

Operating voltage DC

Installation orientation

Shock and vibration resis...

Housing material

Cable ambient temperature...

Degree of protection

Ready delay

Tightening torque

Cable ambient temperature...

Rated conditional short-c...

Test pulses

Test-pulse interval

Extension of risk time ac...

Mounting distance

Mounting method

Static bending radius

Dynamic bending radius

Selected product

119865
7 in stock
119865
Euchner

119865 Euchner - Field evaluation unit CES-FD-AP-…

Weight0.34392072 lb

SeriesCES-FD

Product ClassSafety System

Switching hysteresismin.0,05 mm (With read head...

Assured operating distance Saomin.3,4 mm (With read head ...

Assured release distance Sarmax.10 mm (With read head C...

Category4

Operating distance5 mm (With read head CES-A-...

Mission time20

PFHD4.5 x 10⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Risk time according to EN 60947-5-3max.260 ms

Utilization category acc. to EN 60947-5-2DC-13 24V 150mA (Caution: o...

Off-state current Irmax.0,25 mA

Output voltageUB-1,5V ... UB V DC (Values...

Switching current1 ... 150 mA

Type of outputSemiconductor outputs, p-swi...

Safety classIII

Turn-on timemax.400 ms

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Current consumptionmax.45 mA

Rated insulation voltage Ui75 V

Switching frequencymax.1 Hz

ConnectionConnection cable PUR with pl...

Operating voltage DC24 V DC 15% ... 15% (The ...

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialPlastic, PBT

Cable ambient temperature (static)-20 ... 65 °C

Degree of protectionIP67

Ready delay1 s

Tightening torquemax.1 Nm

Cable ambient temperature (dynamic)-5 ... 65 °C

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Extension of risk time according to EN 60947-5-3 per device-

Mounting distance-

Mounting method-

Static bending radius-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

Category4

Operating distance19 mm

Mission time20

PFHD1.9 x 10⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Risk time according to EN 60947-5-3max.260 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Off-state current Irmax.0,25 mA

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Safety classIII

Turn-on timemax.400 ms

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Current consumptionmax.50 mA (Without taking i...

Rated insulation voltage Ui75 V

Switching frequencymax.1 Hz

ConnectionConnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialPlastic, PBT

Cable ambient temperature (static)-25 ... 65 °C

Degree of protectionIP67

Ready delay10 s

Tightening torquemax.1 Nm

Cable ambient temperature (dynamic)-25 ... 65 °C

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting distancemin.120 mm

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Dynamic bending radius10 x cable diameter

109052
68 in stock
109052
Euchner

109052 Euchner - Non-contact safety switch CES-AR-CR2-..., with flying lead, PUR

Weight1.763696 lb

SeriesCES-AR

Product ClassSafety System

Switching hysteresismin.1 mm

Assured operating distance Saomin.10 mm

Assured release distance Sarmax.40 mm

Category4

Operating distance15 mm

Mission time20

PFHD1.9 x 10⁻⁹

Performance LevelPL e

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Risk time according to EN 60947-5-3max.260 ms

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Off-state current Irmax.0,25 mA

Output voltage0,8 x UB ... UB V DC

Switching currentmax.50 mA

Type of outputp-switching, short circuit-p...

Safety classIII

Turn-on timemax.400 ms

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Current consumptionmax.50 mA (Without taking i...

Rated insulation voltage Ui75 V

Switching frequencymax.1 Hz

Connectionconnection cable PUR, length...

Operating voltage DC24 V DC 15% ... 15% Regu...

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Housing materialPlastic, PBT

Cable ambient temperature (static)-30 ... 65 °C

Degree of protectionIP67, IP69K

Ready delay10 s

Tightening torquemax.1 Nm

Cable ambient temperature (dynamic)-25 ... 65 °C

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Mounting distancemin.120 mm

Mounting methodSurface mounting on metal

Static bending radius5 x cable diameter

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 119865?
The price of 119865 on MQ Automation is $425.01. Order now.

Out if stock but available for backorder.

119865 Euchner - Field evaluation unit CES-FD-AP-…

What can I help you find today?

Recommended parts