117228 Euchner Safety Accessories

117228 on MQ Automation
Euchner
  • 117228
  • 117228
  • 117228

Part#:117228

Alt. Part#:MGB-L1-ARA-AI9A1-M-117228

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

117228 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbuttons, emergency stop

Product Details

  • Weight
    2.27737246 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • Performance Level
    PL e
  • PFHD
    3.7 x 10⁻⁹
  • B10D
    0,13 x 10⁶
  • Product version number
    V4.0.0
  • Category
    4
  • Special features
    With auxiliary contact
  • Switching element
    2 pos. driven NC + 1NO
  • Version
    Emergency stop
  • Switching current
    1 ... 10 mA
  • Assignment diagram
    L1
  • Switching voltage
    UA V
  • Breaking capacity
    max.0,25 W
  • Power supply LED
    24 V DC
  • Output current
    1 ... 200 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Test pulses
    max.5 ms
  • Test-pulse interval
    min.100 ms
  • Output voltage
    UB-2V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Current consumption
    max.80 mA ((no load on outputs))
  • Connection cross-section
    0,25 ... 0,75 mm²
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Unicode
  • Discrepancy time
    max.10 ms
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Rated insulation voltage Ui
    30 V
  • Installation orientation
    Door hinge DIN right
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    Cable entries M20x1.5
  • Degree of protection
    IP65
  • Mechanical life
    0,1 x 10⁶
  • Locking force FZh
    2000 N
  • Weight
    0,75 kg
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Switching frequency
    0,25 Hz
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 117228 on MQ Automation is $1,441.88. Order now.


About the product

Guard locking with guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;3 pushbuttons (illuminated, gn, wh, bu);With cable entry;Unicode


Manufacturer warranty

117228 Euchner

$1,441.88

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,441.88

$1,441.88 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 117228 with other products

Weight

Series

Product Class

Mission time

Performance Level

PFHD

B10D

Product version number

Category

Special features

Switching element

Version

Switching current

Assignment diagram

Switching voltage

Breaking capacity

Power supply LED

Output current

Type of output

Test pulses

Test-pulse interval

Output voltage

Current consumption

Connection cross-section

Operating voltage DC

Transponder coding

Discrepancy time

Risk time according to EN...

Safety class

Rated impulse withstand v...

Degree of contamination (...

Utilization category acc....

Rated insulation voltage ...

Installation orientation

Guard locking principle

Connection

Degree of protection

Mechanical life

Locking force FZh

Housing material

Switching frequency

Ambient temperature

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

117228
0 in stock
117228
Euchner

117228 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbuttons, e...

Weight2.27737246 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

Performance LevelPL e

PFHD3.7 x 10⁻⁹

B10D0,13 x 10⁶

Product version numberV4.0.0

Category4

Special featuresWith auxiliary contact

Switching element2 pos. driven NC + 1NO

VersionEmergency stop

Switching current1 ... 10 mA

Assignment diagramL1

Switching voltageU<sub>A</sub> V

Breaking capacitymax.0,25 W

Power supply LED24 V DC

Output current1 ... 200 mA

Type of outputSemiconductor outputs, p-swi...

Test pulsesmax.5 ms

Test-pulse intervalmin.100 ms

Output voltageUB-2V ... UB V DC (Value at...

Current consumptionmax.80 mA ((no load on outp...

Connection cross-section0,25 ... 0,75 mm²

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingUnicode

Discrepancy timemax.10 ms

Risk time according to EN 60947-5-3max.350 ms

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Rated insulation voltage Ui30 V

Installation orientationDoor hinge DIN right

Guard locking principleClosed-circuit current princ...

ConnectionCable entries M20x1.5

Degree of protectionIP65

Mechanical life0,1 x 10⁶

Locking force FZh2000 N

Housing materialReinforced plastic; die-cast...

Switching frequency0,25 Hz

Ambient temperature-20 ... 55 °C

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

B10D0,13 x 10⁶

Product version number-

Category4

Special features-

Switching element2 pos. driven NC

VersionEmergency stop

Switching current1 ... 150 mA

Assignment diagram-

Switching voltage-

Breaking capacity-

Power supply LED-

Output current-

Type of output2 semiconductor outputs, p-s...

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Output voltage0 ... 1 V DC

Current consumption40 mA

Connection cross-section-

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3-

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Installation orientationDoor hinge DIN right

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Degree of protectionIP65 (Screwed tight plug co...

Mechanical life1 x 10⁶

Locking force FZh-

Housing materialFiber glass reinforced therm...

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

B10D-

Product version number-

Category4

Special features-

Switching element-

Version-

Switching current1 ... 50 mA

Assignment diagram-

Switching voltage-

Breaking capacity-

Power supply LED-

Output current-

Type of outputp-switching, short circuit-p...

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Output voltage0,8xUB ... UB V DC

Current consumption40 mA

Connection cross-section-

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3max.260 ms

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Degree of contamination (external, according to EN 60947-1)3

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Rated insulation voltage Ui50 V

Installation orientationAny

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Mechanical life1 x 10⁶

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Housing materialDie-cast zinc

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 117228?
The price of 117228 on MQ Automation is $1,441.88. Order now.

Out if stock but available for backorder.

117228 Euchner - Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbuttons, emergency stop

What can I help you find today?

Recommended parts