115896 Euchner Safety Accessories

115896 on MQ Automation
Euchner
  • 115896
  • 115896
  • 115896

Part#:115896

Alt. Part#:MGB-L1-APA-AH3A1-S1-L-115896

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18

Product Details

  • Weight
    2.38760346 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Special features
    With auxiliary contact
  • PFHD
    3.7 x 10⁻⁹
  • Mission time
    20 y
  • Performance Level
    PL e
  • Switching element
    2 pos. driven NC + 1NO
  • Category
    4
  • Current consumption
    max.375 mA ((With energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V))
  • Version
    Emergency stop
  • Product version number
    V4.0.0
  • Assignment diagram
    L1
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.5 ms
  • Switching current
    1 ... 10 mA
  • Power supply LED
    24 V DC
  • Breaking capacity
    max.0,25 W
  • Output voltage
    UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Switching voltage
    UA V
  • Output current
    max.50 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Transponder coding
    Unicode
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Locking force FZh
    2000 N
  • Safety class
    III
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Discrepancy time
    max.10 ms
  • Rated insulation voltage Ui
    30 V
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel
  • Guard locking principle
    Closed-circuit current principle
  • Mechanical life
    0,1 x 10⁶
  • Ambient temperature
    -20 ... 55 °C
  • Switching frequency
    0,25 Hz
  • Connection
    Plug connector RC18 (X6)
  • Degree of protection
    IP65
  • Installation orientation
    Door hinge DIN left
  • Weight
    0,75 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 115896 on MQ Automation is $1,564.78. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850;1 indicator (illuminated, gn);1 pushbutton (illuminated, rd);With plug connector RC18;Unicode


Manufacturer warranty

115896 Euchner

$1,564.78

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,564.78

$1,564.78 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 115896 with other products

Weight

Series

Product Class

B10D

Special features

PFHD

Mission time

Performance Level

Switching element

Category

Current consumption

Version

Product version number

Assignment diagram

Operating voltage DC

Test-pulse interval

Test pulses

Switching current

Power supply LED

Breaking capacity

Output voltage

Switching voltage

Output current

Type of output

Transponder coding

Degree of contamination (...

Risk time according to EN...

Locking force FZh

Safety class

Rated impulse withstand v...

Utilization category acc....

Discrepancy time

Rated insulation voltage ...

Housing material

Guard locking principle

Mechanical life

Ambient temperature

Switching frequency

Connection

Degree of protection

Installation orientation

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

115896
0 in stock
115896
Euchner

115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 i...

Weight2.38760346 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Special featuresWith auxiliary contact

PFHD3.7 x 10⁻⁹

Mission time20 y

Performance LevelPL e

Switching element2 pos. driven NC + 1NO

Category4

Current consumptionmax.375 mA ((With energized...

VersionEmergency stop

Product version numberV4.0.0

Assignment diagramL1

Operating voltage DC24 V DC -15% ... 10% ((Re...

Test-pulse intervalmin.100 ms

Test pulsesmax.5 ms

Switching current1 ... 10 mA

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Output voltageUA-2V ... UA V DC (Value at...

Switching voltageU<sub>A</sub> V

Output currentmax.50 mA

Type of outputSemiconductor outputs, p-swi...

Transponder codingUnicode

Degree of contamination (external, according to EN 60947-1)3

Risk time according to EN 60947-5-3max.350 ms

Locking force FZh2000 N

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Discrepancy timemax.10 ms

Rated insulation voltage Ui30 V

Housing materialReinforced plastic; die-cast...

Guard locking principleClosed-circuit current princ...

Mechanical life0,1 x 10⁶

Ambient temperature-20 ... 55 °C

Switching frequency0,25 Hz

ConnectionPlug connector RC18 (X6)

Degree of protectionIP65

Installation orientationDoor hinge DIN left

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Special features-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Switching element2 pos. driven NC

Category4

Current consumption40 mA

VersionEmergency stop

Product version number-

Assignment diagram-

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Switching current1 ... 150 mA

Power supply LED-

Breaking capacity-

Output voltage0 ... 1 V DC

Switching voltage-

Output current-

Type of output2 semiconductor outputs, p-s...

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Risk time according to EN 60947-5-3-

Locking force FZh-

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Discrepancy timemax.10 ms In acc. with EN ...

Rated insulation voltage Ui50 V

Housing materialFiber glass reinforced therm...

Guard locking principle-

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Special features-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Switching element-

Category4

Current consumption40 mA

Version-

Product version number-

Assignment diagram-

Operating voltage DC24 V DC -15% ... 15% Rev...

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Switching current1 ... 50 mA

Power supply LED-

Breaking capacity-

Output voltage0,8xUB ... UB V DC

Switching voltage-

Output current-

Type of outputp-switching, short circuit-p...

Transponder coding-

Degree of contamination (external, according to EN 60947-1)3

Risk time according to EN 60947-5-3max.260 ms

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Safety classIII

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Discrepancy timemax.10 ms In acc. with EN ...

Rated insulation voltage Ui50 V

Housing materialDie-cast zinc

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Ambient temperature-20 ... +55 °C

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

115896
0 in stock
115896
Euchner

115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 i...

Weight2.38760346 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Special featuresWith auxiliary contact

PFHD3.7 x 10⁻⁹

Mission time20 y

Performance LevelPL e

Switching element2 pos. driven NC + 1NO

Category4

Current consumptionmax.375 mA ((With energized...

VersionEmergency stop

Product version numberV4.0.0

Assignment diagramL1

Operating voltage DC24 V DC -15% ... 10% ((Re...

Test-pulse intervalmin.100 ms

Test pulsesmax.5 ms

Switching current1 ... 10 mA

Power supply LED24 V DC

Breaking capacitymax.0,25 W

Output voltageUA-2V ... UA V DC (Value at...

Switching voltageU<sub>A</sub> V

Output currentmax.50 mA

Type of outputSemiconductor outputs, p-swi...

Transponder codingUnicode

Degree of contamination (external, according to EN 60947-1)3

Risk time according to EN 60947-5-3max.350 ms

Locking force FZh2000 N

Safety classIII

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Discrepancy timemax.10 ms

Rated insulation voltage Ui30 V

Housing materialReinforced plastic; die-cast...

Guard locking principleClosed-circuit current princ...

Mechanical life0,1 x 10⁶

Ambient temperature-20 ... 55 °C

Switching frequency0,25 Hz

ConnectionPlug connector RC18 (X6)

Degree of protectionIP65

Installation orientationDoor hinge DIN left

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 115896?
The price of 115896 on MQ Automation is $1,564.78. Order now.

Out if stock but available for backorder.

115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18

What can I help you find today?

Recommended parts