115896 Euchner Safety Accessories
Part#:115896
Alt. Part#:MGB-L1-APA-AH3A1-S1-L-115896
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Product description
115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18
Product Details
- Weight 2.38760346 lb
- Series Spare parts
- Product Class Accessories
- B10D 0,13 x 10⁶
- Special features With auxiliary contact
- PFHD 3.7 x 10⁻⁹
- Mission time 20 y
- Performance Level PL e
- Switching element 2 pos. driven NC + 1NO
- Category 4
- Current consumption max.375 mA ((With energized guard locking solenoid and unloaded outputs OD, OT, OL, OI, +20 °C, 24V))
- Version Emergency stop
- Product version number V4.0.0
- Assignment diagram L1
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Test-pulse interval min.100 ms
- Test pulses max.5 ms
- Switching current 1 ... 10 mA
- Power supply LED 24 V DC
- Breaking capacity max.0,25 W
- Output voltage UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
- Switching voltage UA V
- Output current max.50 mA
- Type of output Semiconductor outputs, p-switching, short circuit-proof
- Transponder coding Unicode
- Degree of contamination (external, according to EN 60947-1) 3
- Risk time according to EN 60947-5-3 max.350 ms
- Locking force FZh 2000 N
- Safety class III
- Rated impulse withstand voltage Uimp 1,5 kV
- Utilization category acc. to EN 60947-5-2 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
- Discrepancy time max.10 ms
- Rated insulation voltage Ui 30 V
- Housing material Reinforced plastic; die-cast zinc nickel-plated, stainless steel
- Guard locking principle Closed-circuit current principle
- Mechanical life 0,1 x 10⁶
- Ambient temperature -20 ... 55 °C
- Switching frequency 0,25 Hz
- Connection Plug connector RC18 (X6)
- Degree of protection IP65
- Installation orientation Door hinge DIN left
- Weight 0,75 kg
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 115896 on MQ Automation is $1,564.78. Order now.
About the product
Guard locking with guard lock monitoring;Emergency stop according to ISO 13850;1 indicator (illuminated, gn);1 pushbutton (illuminated, rd);With plug connector RC18;Unicode
Manufacturer warranty
115896 Euchner
$1,564.78
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$1,564.78
$1,564.78 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 115896 with other products
Weight
Series
Product Class
B10D
Special features
PFHD
Mission time
Performance Level
Switching element
Category
Current consumption
Version
Product version number
Assignment diagram
Operating voltage DC
Test-pulse interval
Test pulses
Switching current
Power supply LED
Breaking capacity
Output voltage
Switching voltage
Output current
Type of output
Transponder coding
Degree of contamination (...
Risk time according to EN...
Locking force FZh
Safety class
Rated impulse withstand v...
Utilization category acc....
Discrepancy time
Rated insulation voltage ...
Housing material
Guard locking principle
Mechanical life
Ambient temperature
Switching frequency
Connection
Degree of protection
Installation orientation
For the approval acc. to ...
Operating current
Repeat accuracy R
Detent mechanism
Off-state current Ir
Operating voltage
Turn-on time
Switching load
EMC protection requiremen...
Connection rating
Fusing
Overtravel
Extraction force
Actuating force
Shock and vibration resis...
Approach speed
Ready delay
Additional feature
Solenoid duty cycle
Solenoid operating voltag...
Extension of risk time ac...
Locking force Fmax
Retention force
Selected product

115896
Euchner
115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 i...
Weight2.38760346 lb
SeriesSpare parts
Product ClassAccessories
B10D0,13 x 10⁶
Special featuresWith auxiliary contact
PFHD3.7 x 10⁻⁹
Mission time20 y
Performance LevelPL e
Switching element2 pos. driven NC + 1NO
Category4
Current consumptionmax.375 mA ((With energized...
VersionEmergency stop
Product version numberV4.0.0
Assignment diagramL1
Operating voltage DC24 V DC -15% ... 10% ((Re...
Test-pulse intervalmin.100 ms
Test pulsesmax.5 ms
Switching current1 ... 10 mA
Power supply LED24 V DC
Breaking capacitymax.0,25 W
Output voltageUA-2V ... UA V DC (Value at...
Switching voltageU<sub>A</sub> V
Output currentmax.50 mA
Type of outputSemiconductor outputs, p-swi...
Transponder codingUnicode
Degree of contamination (external, according to EN 60947-1)3
Risk time according to EN 60947-5-3max.350 ms
Locking force FZh2000 N
Safety classIII
Rated impulse withstand voltage Uimp1,5 kV
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Discrepancy timemax.10 ms
Rated insulation voltage Ui30 V
Housing materialReinforced plastic; die-cast...
Guard locking principleClosed-circuit current princ...
Mechanical life0,1 x 10⁶
Ambient temperature-20 ... 55 °C
Switching frequency0,25 Hz
ConnectionPlug connector RC18 (X6)
Degree of protectionIP65
Installation orientationDoor hinge DIN left
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Off-state current Ir-
Operating voltage-
Turn-on time-
Switching load-
EMC protection requirements-
Connection rating-
Fusing-
Overtravel-
Extraction force-
Actuating force-
Shock and vibration resistance-
Approach speed-
Ready delay-
Additional feature-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
Weight3.968316 lb
SeriesMGBS-P-I-AP
Product ClassSafety System
B10D0,13 x 10⁶
Special features-
PFHD4.1 x 10 ⁻⁹
Mission time20 y
Performance LevelPL e
Switching element2 pos. driven NC
Category4
Current consumption40 mA
VersionEmergency stop
Product version number-
Assignment diagram-
Operating voltage DC24 V DC -15% ... 15% Rev...
Test-pulse intervalmin.100 ms
Test pulsesmax.0,3 ms (Applies for a l...
Switching current1 ... 150 mA
Power supply LED-
Breaking capacity-
Output voltage0 ... 1 V DC
Switching voltage-
Output current-
Type of output2 semiconductor outputs, p-s...
Transponder coding-
Degree of contamination (external, according to EN 60947-1)3
Risk time according to EN 60947-5-3-
Locking force FZh-
Safety classIII
Rated impulse withstand voltage Uimp0,5 kV
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Discrepancy timemax.10 ms In acc. with EN ...
Rated insulation voltage Ui50 V
Housing materialFiber glass reinforced therm...
Guard locking principle-
Mechanical life1 x 10⁶
Ambient temperature-20 ... +55 °C
Switching frequencymax.0,5 Hz
Connection2 plug connectors M12, 5-pin
Degree of protectionIP65 (Screwed tight plug co...
Installation orientationDoor hinge DIN right
For the approval acc. to UL the following appliesOperation only with UL class...
Operating current1 ... 100 mA
Repeat accuracy R10 %
Detent mechanismSnap-in bolt
Off-state current Irmax.0,25 mA
Operating voltage5 ... 24 V
Turn-on timemax.400 ms
Switching load24V DC, class 2 (Alternativ...
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Connection rating1 W
Fusing0,25 ... 8 A
Overtravel5 mm
Extraction force20 N
Actuating force10 N
Shock and vibration resistanceIn acc. with EN 60947-5-3
Approach speedmax.20 m/min
Ready delaymax.1 s
Additional feature-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-

122813
Euchner
122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release
Weight1.763696 lb
SeriesCTP-AR
Product ClassSafety System
B10D-
Special features-
PFHD4.1 x 10 ⁻⁹
Mission time20 y
Performance LevelPL e
Switching element-
Category4
Current consumption40 mA
Version-
Product version number-
Assignment diagram-
Operating voltage DC24 V DC -15% ... 15% Rev...
Test-pulse intervalmin.140 ms
Test pulsesmax.1,0 ms (Applies for a l...
Switching current1 ... 50 mA
Power supply LED-
Breaking capacity-
Output voltage0,8xUB ... UB V DC
Switching voltage-
Output current-
Type of outputp-switching, short circuit-p...
Transponder coding-
Degree of contamination (external, according to EN 60947-1)3
Risk time according to EN 60947-5-3max.260 ms
Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...
Safety classIII
Rated impulse withstand voltage Uimp0,5 kV
Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...
Discrepancy timemax.10 ms In acc. with EN ...
Rated insulation voltage Ui50 V
Housing materialDie-cast zinc
Guard locking principleClosed-circuit current princ...
Mechanical life1 x 10⁶
Ambient temperature-20 ... +55 °C
Switching frequencymax.0,5 Hz
Connection2 plug connectors M12, 5 and...
Degree of protectionIP67/IP69/IP69K (Screwed ti...
Installation orientationAny
For the approval acc. to UL the following appliesOperation only with UL class...
Operating current-
Repeat accuracy R10 %
Detent mechanism-
Off-state current Irmax.0,25 mA
Operating voltage-
Turn-on timemax.400 ms
Switching load24V DC, class 2 (Alternativ...
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Connection rating6 W
Fusing0,25 ... 8 A
Overtravel5 mm
Extraction force20 N
Actuating force10 N
Shock and vibration resistanceIn acc. with EN 60947-5-3
Approach speedmax.20 m/min
Ready delay8 s
Additional featureEscape release actuated by p...
Solenoid duty cycle100 %
Solenoid operating voltage DC24 V DC -15% ... +10% Re...
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Locking force Fmax3900 N
Retention force20 N

115896
Euchner
115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 i...
Weight2.38760346 lb
SeriesSpare parts
Product ClassAccessories
B10D0,13 x 10⁶
Special featuresWith auxiliary contact
PFHD3.7 x 10⁻⁹
Mission time20 y
Performance LevelPL e
Switching element2 pos. driven NC + 1NO
Category4
Current consumptionmax.375 mA ((With energized...
VersionEmergency stop
Product version numberV4.0.0
Assignment diagramL1
Operating voltage DC24 V DC -15% ... 10% ((Re...
Test-pulse intervalmin.100 ms
Test pulsesmax.5 ms
Switching current1 ... 10 mA
Power supply LED24 V DC
Breaking capacitymax.0,25 W
Output voltageUA-2V ... UA V DC (Value at...
Switching voltageU<sub>A</sub> V
Output currentmax.50 mA
Type of outputSemiconductor outputs, p-swi...
Transponder codingUnicode
Degree of contamination (external, according to EN 60947-1)3
Risk time according to EN 60947-5-3max.350 ms
Locking force FZh2000 N
Safety classIII
Rated impulse withstand voltage Uimp1,5 kV
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Discrepancy timemax.10 ms
Rated insulation voltage Ui30 V
Housing materialReinforced plastic; die-cast...
Guard locking principleClosed-circuit current princ...
Mechanical life0,1 x 10⁶
Ambient temperature-20 ... 55 °C
Switching frequency0,25 Hz
ConnectionPlug connector RC18 (X6)
Degree of protectionIP65
Installation orientationDoor hinge DIN left
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Off-state current Ir-
Operating voltage-
Turn-on time-
Switching load-
EMC protection requirements-
Connection rating-
Fusing-
Overtravel-
Extraction force-
Actuating force-
Shock and vibration resistance-
Approach speed-
Ready delay-
Additional feature-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 115896?
The price of 115896 on MQ Automation is $1,564.78. Order now.
Out if stock but available for backorder.
115896 Euchner - Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18
Similar products from: Safety Accessories
What can I help you find today?