115419 Euchner Safety Accessories

115419 on MQ Automation
Euchner
  • 115419
  • 115419

Part#:115419

Alt. Part#:MGB-L1B-PNC-R-115419

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

115419 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, push-pull plug, RC12

Product Details

  • Weight
    7.8704934 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Diagnostic Coverage (DC)
    99
  • PFHD
    4.1 x 10⁻⁸
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • B10D
    (According to manufacturer’s specifications)
  • Performance Level
    PL e
  • Category
    4
  • Product version number
    V3.30.10
  • Switching element
    1NO
  • Assignment diagram
    L0
  • Version
    Illuminated push buttons
  • Color
    Yellow
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Assured release distance Sar
    max.65 mm
  • Transponder coding
    Multicode
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated insulation voltage Ui
    75 V
  • Current consumption
    max.500 mA
  • Locking force FZh
    2000 N
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Connection
    Push-pull RJ45 (X4 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Guard locking principle
    Closed-circuit current principle
  • Switching frequency
    0,25 Hz
  • Degree of protection
    IP54
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Ambient temperature
    -20 ... 55 °C
  • Installation orientation
    Door hinge DIN right
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Mechanical life
    0,1 x 10⁶
  • Weight
    3,1 kg

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 115419 on MQ Automation is $3,018.55. Order now.


About the product

Guard locking with guard lock monitoring;3 illuminated pushbuttons;including adhesive labels;Push-pull plug;including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Integrated Profinet RT switch;Multicode


Manufacturer warranty

115419 Euchner

$3,018.55

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,018.55

$3,018.55 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 115419 with other products

Weight

Series

Product Class

Diagnostic Coverage (DC)

PFHD

Mission time

Safety Integrity Level

B10D

Performance Level

Category

Product version number

Switching element

Assignment diagram

Version

Color

Bus data protocol

Safety data protocol

Assured release distance ...

Transponder coding

Fusing

Auxiliary voltage DC

Operating voltage DC

Safety class

Degree of contamination (...

Connecting cable

EMC protection requiremen...

Maximum feed-in current i...

Rated insulation voltage ...

Current consumption

Locking force FZh

Rated impulse withstand v...

Connection

Guard locking principle

Switching frequency

Degree of protection

Housing material

Ambient temperature

Installation orientation

Shock and vibration resis...

Reaction time

Mechanical life

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

115419
0 in stock
115419
Euchner

115419 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) wi...

Weight7.8704934 lb

SeriesSpare parts

Product ClassAccessories

Diagnostic Coverage (DC)99

PFHD4.1 x 10⁻⁸

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

B10D(According to manufacturer’s...

Performance LevelPL e

Category4

Product version numberV3.30.10

Switching element1NO

Assignment diagramL0

VersionIlluminated push buttons

ColorYellow

Bus data protocolProfinet (IEC 61158 type 10)

Safety data protocolProfisafe (IEC 61784-3-3)

Assured release distance Sarmax.65 mm

Transponder codingMulticode

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cableProfinet I/O cable, at least...

EMC protection requirementsIn accordance with EN 61000-...

Maximum feed-in current in the connection blockmax.4000 mA

Rated insulation voltage Ui75 V

Current consumptionmax.500 mA

Locking force FZh2000 N

Rated impulse withstand voltage Uimp0,5 kV

ConnectionPush-pull RJ45 (X4 (The doc...

Guard locking principleClosed-circuit current princ...

Switching frequency0,25 Hz

Degree of protectionIP54

Housing materialReinforced plastic, die-cast...

Ambient temperature-20 ... 55 °C

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction timemax.550 ms Switch-off time...

Mechanical life0,1 x 10⁶

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Safety Integrity Level-

B10D0,13 x 10⁶

Performance LevelPL e

Category4

Product version number-

Switching element2 pos. driven NC

Assignment diagram-

VersionEmergency stop

Color-

Bus data protocol-

Safety data protocol-

Assured release distance Sar-

Transponder coding-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Current consumption40 mA

Locking force FZh-

Rated impulse withstand voltage Uimp0,5 kV

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Switching frequencymax.0,5 Hz

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

Ambient temperature-20 ... +55 °C

Installation orientationDoor hinge DIN right

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction time-

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Safety Integrity Level-

B10D-

Performance LevelPL e

Category4

Product version number-

Switching element-

Assignment diagram-

Version-

Color-

Bus data protocol-

Safety data protocol-

Assured release distance Sar-

Transponder coding-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Connecting cable-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Current consumption40 mA

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Rated impulse withstand voltage Uimp0,5 kV

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Switching frequencymax.0,5 Hz

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

Ambient temperature-20 ... +55 °C

Installation orientationAny

Shock and vibration resistanceIn acc. with EN 60947-5-3

Reaction time-

Mechanical life1 x 10⁶

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 115419?
The price of 115419 on MQ Automation is $3,018.55. Order now.

Out if stock but available for backorder.

115419 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, push-pull plug, RC12

What can I help you find today?

Recommended parts