114943 Euchner Electronic Components


Part#:114943
Manufacturer:Euchner
Category:Electronic Components
Product Lifecycle:Active
Product description
Safety system ESL-IH-AR... , plug connector M12
Product Details
- Mission time 20 y
- Performance Level PL e
- PFHD 1.9 x 10⁻⁹
- Category 4
- For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
- Assured release distance Sar max.0 mm (For the calculation of safety parameters an s_ar of 0 mm in the door opening direction can be assumed.)
- Output voltage 0,8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
- Switching current max.50 mA
- Type of output p-switching, short circuit-proof
- Transponder coding Multicode
- Risk time according to EN 60947-5-3 max.400 ms
- Switching load DC 24 V, class 2
- Safety class III
- Discrepancy time 10 ms (Maximum time difference between the switching points on the safety outputs FO1A and FO1B)
- Switching delay from state change max.400 ms (Corresponds to the risk time according to EN 60947-5-3. This is the maximum switch-off delay for the safety outputs after pulling the handle module.)
- Degree of contamination (external, according to EN 60947-1) 3
- EMC protection requirements In acc. with EN IEC 60947-5-3
- Rated impulse withstand voltage Uimp 0,8 kV
- Rated insulation voltage Ui 75 V
- Fusing 0,25 ... 8 A
- Utilization category acc. to EN 60947-5-2 DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
- Rated conditional short-circuit current 100 A
- Current consumption max.40 mA
- Operating voltage 24 V -15 % ... 15 %
- Connection M12 plug connector, 8-pin
- Mechanical life 0,1 x 10⁶
- Shock and vibration resistance In acc. with EN 60947-5-3
- Tightening torque max.10 Nm
- Weight 0,4 kg
- Switching frequency max.0,5 Hz
- Degree of protection IP67
- Installation orientation Any
- Housing material Die-cast aluminum, powder coated, black
- Ambient temperature -20 ... 55 °C
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
114943 Euchner
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 114943 with other products
Mission time
Performance Level
PFHD
Category
For the approval acc. to ...
Assured release distance ...
Output voltage
Switching current
Type of output
Transponder coding
Risk time according to EN...
Switching load
Safety class
Discrepancy time
Switching delay from stat...
Degree of contamination (...
EMC protection requiremen...
Rated impulse withstand v...
Rated insulation voltage ...
Fusing
Utilization category acc....
Rated conditional short-c...
Current consumption
Operating voltage
Connection
Mechanical life
Shock and vibration resis...
Tightening torque
Weight
Switching frequency
Degree of protection
Installation orientation
Housing material
Ambient temperature
Series
Product Class
Switching hysteresis
Assured operating distanc...
Operating distance
Repeat accuracy R
Off-state current Ir
Test pulses
Test-pulse interval
Turn-on time
Extension of risk time ac...
Mounting distance
Operating voltage DC
Ready delay
Cable ambient temperature...
Mounting method
Static bending radius
Cable ambient temperature...
Dynamic bending radius
Selected product
Mission time20 y
Performance LevelPL e
PFHD1.9 x 10⁻⁹
Category4
For the approval acc. to UL the following appliesOperation only with UL class...
Assured release distance Sarmax.0 mm (For the calculati...
Output voltage0,8 x UB ... UB V DC (Value...
Switching currentmax.50 mA
Type of outputp-switching, short circuit-p...
Transponder codingMulticode
Risk time according to EN 60947-5-3max.400 ms
Switching loadDC 24 V, class 2
Safety classIII
Discrepancy time10 ms (Maximum time differe...
Switching delay from state changemax.400 ms (Corresponds to ...
Degree of contamination (external, according to EN 60947-1)3
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Rated impulse withstand voltage Uimp0,8 kV
Rated insulation voltage Ui75 V
Fusing0,25 ... 8 A
Utilization category acc. to EN 60947-5-2DC-13 24V 150mA (Caution: o...
Rated conditional short-circuit current100 A
Current consumptionmax.40 mA
Operating voltage24 V -15 % ... 15 %
ConnectionM12 plug connector, 8-pin
Mechanical life0,1 x 10⁶
Shock and vibration resistanceIn acc. with EN 60947-5-3
Tightening torquemax.10 Nm
Weight0,4 kg
Switching frequencymax.0,5 Hz
Degree of protectionIP67
Installation orientationAny
Housing materialDie-cast aluminum, powder co...
Ambient temperature-20 ... 55 °C
Series-
Product Class-
Switching hysteresis-
Assured operating distance Sao-
Operating distance-
Repeat accuracy R-
Off-state current Ir-
Test pulses-
Test-pulse interval-
Turn-on time-
Extension of risk time according to EN 60947-5-3 per device-
Mounting distance-
Operating voltage DC-
Ready delay-
Cable ambient temperature (dynamic)-
Mounting method-
Static bending radius-
Cable ambient temperature (static)-
Dynamic bending radius-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
Out if stock but available for backorder.
Safety system ESL-IH-AR... , plug connector M12
Similar products from: Electronic Components
What can I help you find today?