114426 Euchner Safety Accessories
Part#:114426
Alt. Part#:MGB-L1B-PNA-L-114426
Manufacturer:Euchner
Category:Safety Accessories
Product Lifecycle:Active
Product description
114426 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, 7/8" and M12 plugs
Product Details
- Weight 8.16591248 lb
- Series Spare parts
- Product Class Accessories
- B10D 0,13 x 10⁶
- Mission time 20
- Safety Integrity Level SIL 3 (EN 62061:2005)
- Diagnostic Coverage (DC) 99
- PFHD 4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
- Performance Level PL e
- Category 4
- Switching element 1NO
- Product version number V3.30.10
- Assignment diagram B1
- Special features Printed
- Safety data protocol Profisafe (IEC 61784-3-3)
- Color white
- Version Illuminated push buttons
- Bus data protocol Profinet (IEC 61158 type 10)
- Fusing min.1 A Slow blow
- Operating voltage DC 24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
- Assured release distance Sar max.65 mm
- Auxiliary voltage DC 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
- Transponder coding Unicode
- Safety class III
- Degree of contamination (external, according to EN 60947-1) 3
- Maximum feed-in current in the connection block max.4000 mA
- Connecting cable Profinet I/O cable, at least cat. 5e
- Current consumption max.500 mA
- Rated impulse withstand voltage Uimp 0,5 kV
- EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
- Guard locking principle Closed-circuit current principle
- Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
- Locking force FZh 2000 N
- Rated insulation voltage Ui 75 V
- Connection 7/8" Power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
- Switching frequency 0,25 Hz
- Mechanical life 0,1 x 10⁶
- Degree of protection IP54
- Installation orientation Door hinge DIN left
- Reaction time max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
- Ambient temperature -20 ... 55 °C
- Weight 3,1 kg
- Shock and vibration resistance In acc. with EN 60947-5-3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 114426 on MQ Automation is $3,063.78. Order now.
About the product
Guard locking with guard lock monitoring;Emergency stop according to ISO 13850;2 illuminated white pushbuttons with symbol;including adhesive labels;Connection via 7/8" and M12 plugs;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode
Manufacturer warranty
114426 Euchner
$3,063.78
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$3,063.78
$3,063.78 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 114426 with other products
Weight
Series
Product Class
B10D
Mission time
Safety Integrity Level
Diagnostic Coverage (DC)
PFHD
Performance Level
Category
Switching element
Product version number
Assignment diagram
Special features
Safety data protocol
Color
Version
Bus data protocol
Fusing
Operating voltage DC
Assured release distance ...
Auxiliary voltage DC
Transponder coding
Safety class
Degree of contamination (...
Maximum feed-in current i...
Connecting cable
Current consumption
Rated impulse withstand v...
EMC protection requiremen...
Guard locking principle
Housing material
Locking force FZh
Rated insulation voltage ...
Connection
Switching frequency
Mechanical life
Degree of protection
Installation orientation
Reaction time
Ambient temperature
Shock and vibration resis...
For the approval acc. to ...
Operating current
Repeat accuracy R
Detent mechanism
Discrepancy time
Off-state current Ir
Operating voltage
Switching current
Type of output
Turn-on time
Switching load
Output voltage
Connection rating
Utilization category acc....
Overtravel
Test-pulse interval
Extraction force
Test pulses
Actuating force
Approach speed
Ready delay
Additional feature
Risk time according to EN...
Solenoid duty cycle
Solenoid operating voltag...
Extension of risk time ac...
Locking force Fmax
Retention force
Selected product

114426
Euchner
114426 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) wi...
Weight8.16591248 lb
SeriesSpare parts
Product ClassAccessories
B10D0,13 x 10⁶
Mission time20
Safety Integrity LevelSIL 3 (EN 62061:2005)
Diagnostic Coverage (DC)99
PFHD4.07 x 10⁻⁸ (Fixed failure ...
Performance LevelPL e
Category4
Switching element1NO
Product version numberV3.30.10
Assignment diagramB1
Special featuresPrinted
Safety data protocolProfisafe (IEC 61784-3-3)
Colorwhite
VersionIlluminated push buttons
Bus data protocolProfinet (IEC 61158 type 10)
Fusingmin.1 A Slow blow
Operating voltage DC24 V DC -15% ... 10% ((Re...
Assured release distance Sarmax.65 mm
Auxiliary voltage DC24 V DC -15% ... +10% (Th...
Transponder codingUnicode
Safety classIII
Degree of contamination (external, according to EN 60947-1)3
Maximum feed-in current in the connection blockmax.4000 mA
Connecting cableProfinet I/O cable, at least...
Current consumptionmax.500 mA
Rated impulse withstand voltage Uimp0,5 kV
EMC protection requirementsIn accordance with EN 61000-...
Guard locking principleClosed-circuit current princ...
Housing materialReinforced plastic, die-cast...
Locking force FZh2000 N
Rated insulation voltage Ui75 V
Connection7/8" Power (X1 (The documen...
Switching frequency0,25 Hz
Mechanical life0,1 x 10⁶
Degree of protectionIP54
Installation orientationDoor hinge DIN left
Reaction timemax.550 ms Switch-off time...
Ambient temperature-20 ... 55 °C
Shock and vibration resistanceIn acc. with EN 60947-5-3
For the approval acc. to UL the following applies-
Operating current-
Repeat accuracy R-
Detent mechanism-
Discrepancy time-
Off-state current Ir-
Operating voltage-
Switching current-
Type of output-
Turn-on time-
Switching load-
Output voltage-
Connection rating-
Utilization category acc. to EN 60947-5-2-
Overtravel-
Test-pulse interval-
Extraction force-
Test pulses-
Actuating force-
Approach speed-
Ready delay-
Additional feature-
Risk time according to EN 60947-5-3-
Solenoid duty cycle-
Solenoid operating voltage DC-
Extension of risk time according to EN 60947-5-3 per device-
Locking force Fmax-
Retention force-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 114426?
The price of 114426 on MQ Automation is $3,063.78. Order now.
Out if stock but available for backorder.
114426 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, 7/8" and M12 plugs
Similar products from: Safety Accessories
What can I help you find today?