114426 Euchner Safety Accessories

114426 on MQ Automation
Euchner
  • 114426
  • 114426

Part#:114426

Alt. Part#:MGB-L1B-PNA-L-114426

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

114426 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, 7/8" and M12 plugs

Product Details

  • Weight
    8.16591248 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • B10D
    0,13 x 10⁶
  • Mission time
    20
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • Diagnostic Coverage (DC)
    99
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Performance Level
    PL e
  • Category
    4
  • Switching element
    1NO
  • Product version number
    V3.30.10
  • Assignment diagram
    B1
  • Special features
    Printed
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Color
    white
  • Version
    Illuminated push buttons
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Fusing
    min.1 A Slow blow
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Assured release distance Sar
    max.65 mm
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Transponder coding
    Unicode
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Current consumption
    max.500 mA
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Guard locking principle
    Closed-circuit current principle
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel
  • Locking force FZh
    2000 N
  • Rated insulation voltage Ui
    75 V
  • Connection
    7/8" Power (X1 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Switching frequency
    0,25 Hz
  • Mechanical life
    0,1 x 10⁶
  • Degree of protection
    IP54
  • Installation orientation
    Door hinge DIN left
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Ambient temperature
    -20 ... 55 °C
  • Weight
    3,1 kg
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 114426 on MQ Automation is $3,063.78. Order now.


About the product

Guard locking with guard lock monitoring;Emergency stop according to ISO 13850;2 illuminated white pushbuttons with symbol;including adhesive labels;Connection via 7/8&quot; and M12 plugs;Pre-assembled on mounting plates;Integrated Profinet RT switch;Unicode


Manufacturer warranty

114426 Euchner

$3,063.78

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,063.78

$3,063.78 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 114426 with other products

Weight

Series

Product Class

B10D

Mission time

Safety Integrity Level

Diagnostic Coverage (DC)

PFHD

Performance Level

Category

Switching element

Product version number

Assignment diagram

Special features

Safety data protocol

Color

Version

Bus data protocol

Fusing

Operating voltage DC

Assured release distance ...

Auxiliary voltage DC

Transponder coding

Safety class

Degree of contamination (...

Maximum feed-in current i...

Connecting cable

Current consumption

Rated impulse withstand v...

EMC protection requiremen...

Guard locking principle

Housing material

Locking force FZh

Rated insulation voltage ...

Connection

Switching frequency

Mechanical life

Degree of protection

Installation orientation

Reaction time

Ambient temperature

Shock and vibration resis...

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

114426
0 in stock
114426
Euchner

114426 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) wi...

Weight8.16591248 lb

SeriesSpare parts

Product ClassAccessories

B10D0,13 x 10⁶

Mission time20

Safety Integrity LevelSIL 3 (EN 62061:2005)

Diagnostic Coverage (DC)99

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Performance LevelPL e

Category4

Switching element1NO

Product version numberV3.30.10

Assignment diagramB1

Special featuresPrinted

Safety data protocolProfisafe (IEC 61784-3-3)

Colorwhite

VersionIlluminated push buttons

Bus data protocolProfinet (IEC 61158 type 10)

Fusingmin.1 A Slow blow

Operating voltage DC24 V DC -15% ... 10% ((Re...

Assured release distance Sarmax.65 mm

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Transponder codingUnicode

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Maximum feed-in current in the connection blockmax.4000 mA

Connecting cableProfinet I/O cable, at least...

Current consumptionmax.500 mA

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn accordance with EN 61000-...

Guard locking principleClosed-circuit current princ...

Housing materialReinforced plastic, die-cast...

Locking force FZh2000 N

Rated insulation voltage Ui75 V

Connection7/8" Power (X1 (The documen...

Switching frequency0,25 Hz

Mechanical life0,1 x 10⁶

Degree of protectionIP54

Installation orientationDoor hinge DIN left

Reaction timemax.550 ms Switch-off time...

Ambient temperature-20 ... 55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

B10D0,13 x 10⁶

Mission time20 y

Safety Integrity Level-

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Switching element2 pos. driven NC

Product version number-

Assignment diagram-

Special features-

Safety data protocol-

Color-

VersionEmergency stop

Bus data protocol-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Assured release distance Sar-

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Maximum feed-in current in the connection block-

Connecting cable-

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Guard locking principle-

Housing materialFiber glass reinforced therm...

Locking force FZh-

Rated insulation voltage Ui50 V

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Installation orientationDoor hinge DIN right

Reaction time-

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

B10D-

Mission time20 y

Safety Integrity Level-

Diagnostic Coverage (DC)-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Category4

Switching element-

Product version number-

Assignment diagram-

Special features-

Safety data protocol-

Color-

Version-

Bus data protocol-

Fusing0,25 ... 8 A

Operating voltage DC24 V DC -15% ... 15% Rev...

Assured release distance Sar-

Auxiliary voltage DC-

Transponder coding-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Maximum feed-in current in the connection block-

Connecting cable-

Current consumption40 mA

Rated impulse withstand voltage Uimp0,5 kV

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Guard locking principleClosed-circuit current princ...

Housing materialDie-cast zinc

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Rated insulation voltage Ui50 V

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Installation orientationAny

Reaction time-

Ambient temperature-20 ... +55 °C

Shock and vibration resistanceIn acc. with EN 60947-5-3

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 114426?
The price of 114426 on MQ Automation is $3,063.78. Order now.

Out if stock but available for backorder.

114426 Euchner - Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 3 control elements, 7/8&quot; and M12 plugs

What can I help you find today?

Recommended parts