114398 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, push-pull plug, RC12

Product Details

  • Weight
    7.87710726 lb
  • Series
    MGB-PN (Profinet)
  • Product Class
    Safety System
  • Mission time
    20
  • Diagnostic Coverage (DC)
    99
  • Safety Integrity Level
    SIL 3 (EN 62061:2005)
  • PFHD
    4.07 x 10⁻⁸ (Fixed failure rate without consideration of faults in wearing parts.)
  • Performance Level
    PL e
  • B10D
    (According to manufacturer’s specifications)
  • Category
    4
  • Product version number
    V3.30.10
  • Switching element
    1NO
  • Color
    Red
  • Version
    Illuminated push buttons
  • Assignment diagram
    L0
  • Safety data protocol
    Profisafe (IEC 61784-3-3)
  • Bus data protocol
    Profinet (IEC 61158 type 10)
  • Assured release distance Sar
    max.65 mm
  • Fusing
    min.1 A Slow blow
  • Auxiliary voltage DC
    24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Transponder coding
    Multicode
  • Safety class
    III
  • Connecting cable
    Profinet I/O cable, at least cat. 5e
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In accordance with EN 61000-4 and EN 61326-3-1
  • Rated impulse withstand voltage Uimp
    0,5 kV
  • Current consumption
    max.500 mA
  • Maximum feed-in current in the connection block
    max.4000 mA
  • Rated insulation voltage Ui
    75 V
  • Locking force FZh
    2000 N
  • Installation orientation
    Door hinge DIN right
  • Reaction time
    max.550 ms Switch-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
  • Mechanical life
    0,1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Connection
    Push-pull RJ45 (X3 (The document PROFINET "Cabling and Interconnection Technology" from the PNO aids in the correct selection of wiring.))
  • Guard locking principle
    Open-circuit current principle
  • Switching frequency
    0,25 Hz
  • Ambient temperature
    -20 ... 55 °C
  • Degree of protection
    IP54
  • Weight
    3,1 kg
  • Housing material
    Reinforced plastic, die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 114398 on MQ Automation is $3,018.55. Order now.


About the product

Guard locking with guard lock monitoring;3 illuminated pushbuttons;including adhesive labels;Push-pull plug;including terminal plug for enabling switch (RC12, 12-pin);Pre-assembled on mounting plates;Integrated Profinet RT switch;Multicode


Manufacturer warranty

114398 Euchner

$3,018.55

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$3,018.55

$3,018.55 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 114398 with other products

Weight

Series

Product Class

Mission time

Diagnostic Coverage (DC)

Safety Integrity Level

PFHD

Performance Level

B10D

Category

Product version number

Switching element

Color

Version

Assignment diagram

Safety data protocol

Bus data protocol

Assured release distance ...

Fusing

Auxiliary voltage DC

Operating voltage DC

Transponder coding

Safety class

Connecting cable

Degree of contamination (...

EMC protection requiremen...

Rated impulse withstand v...

Current consumption

Maximum feed-in current i...

Rated insulation voltage ...

Locking force FZh

Installation orientation

Reaction time

Mechanical life

Shock and vibration resis...

Connection

Guard locking principle

Switching frequency

Ambient temperature

Degree of protection

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Discrepancy time

Off-state current Ir

Operating voltage

Switching current

Type of output

Turn-on time

Switching load

Output voltage

Connection rating

Utilization category acc....

Overtravel

Test-pulse interval

Extraction force

Test pulses

Actuating force

Approach speed

Ready delay

Additional feature

Risk time according to EN...

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

114398
0 in stock
114398
Euchner

114398 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) ...

Weight7.87710726 lb

SeriesMGB-PN (Profinet)

Product ClassSafety System

Mission time20

Diagnostic Coverage (DC)99

Safety Integrity LevelSIL 3 (EN 62061:2005)

PFHD4.07 x 10⁻⁸ (Fixed failure ...

Performance LevelPL e

B10D(According to manufacturer’s...

Category4

Product version numberV3.30.10

Switching element1NO

ColorRed

VersionIlluminated push buttons

Assignment diagramL0

Safety data protocolProfisafe (IEC 61784-3-3)

Bus data protocolProfinet (IEC 61158 type 10)

Assured release distance Sarmax.65 mm

Fusingmin.1 A Slow blow

Auxiliary voltage DC24 V DC -15% ... +10% (Th...

Operating voltage DC24 V DC -15% ... 10% ((Re...

Transponder codingMulticode

Safety classIII

Connecting cableProfinet I/O cable, at least...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn accordance with EN 61000-...

Rated impulse withstand voltage Uimp0,5 kV

Current consumptionmax.500 mA

Maximum feed-in current in the connection blockmax.4000 mA

Rated insulation voltage Ui75 V

Locking force FZh2000 N

Installation orientationDoor hinge DIN right

Reaction timemax.550 ms Switch-off time...

Mechanical life0,1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

ConnectionPush-pull RJ45 (X3 (The doc...

Guard locking principleOpen-circuit current princip...

Switching frequency0,25 Hz

Ambient temperature-20 ... 55 °C

Degree of protectionIP54

Housing materialReinforced plastic, die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Discrepancy time-

Off-state current Ir-

Operating voltage-

Switching current-

Type of output-

Turn-on time-

Switching load-

Output voltage-

Connection rating-

Utilization category acc. to EN 60947-5-2-

Overtravel-

Test-pulse interval-

Extraction force-

Test pulses-

Actuating force-

Approach speed-

Ready delay-

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Diagnostic Coverage (DC)-

Safety Integrity Level-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

B10D0,13 x 10⁶

Category4

Product version number-

Switching element2 pos. driven NC

Color-

VersionEmergency stop

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Current consumption40 mA

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Locking force FZh-

Installation orientationDoor hinge DIN right

Reaction time-

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Connection2 plug connectors M12, 5-pin

Guard locking principle-

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Degree of protectionIP65 (Screwed tight plug co...

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0 ... 1 V DC

Connection rating1 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.100 ms

Extraction force20 N

Test pulsesmax.0,3 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Risk time according to EN 60947-5-3-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Diagnostic Coverage (DC)-

Safety Integrity Level-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

B10D-

Category4

Product version number-

Switching element-

Color-

Version-

Assignment diagram-

Safety data protocol-

Bus data protocol-

Assured release distance Sar-

Fusing0,25 ... 8 A

Auxiliary voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Transponder coding-

Safety classIII

Connecting cable-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Rated impulse withstand voltage Uimp0,5 kV

Current consumption40 mA

Maximum feed-in current in the connection block-

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Installation orientationAny

Reaction time-

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Connection2 plug connectors M12, 5 and...

Guard locking principleClosed-circuit current princ...

Switching frequencymax.0,5 Hz

Ambient temperature-20 ... +55 °C

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Operating voltage-

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

Output voltage0,8xUB ... UB V DC

Connection rating6 W

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Overtravel5 mm

Test-pulse intervalmin.140 ms

Extraction force20 N

Test pulsesmax.1,0 ms (Applies for a l...

Actuating force10 N

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Risk time according to EN 60947-5-3max.260 ms

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 114398?
The price of 114398 on MQ Automation is $3,018.55. Order now.

Out if stock but available for backorder.

114398 Euchner - Evaluation module and bus module MGB-L2...-PN... (guard locking by solenoid force) with 3 control elements, push-pull plug, RC12

What can I help you find today?

Recommended parts