Product description

113965 Euchner - Non-contact safety switch CET-AR-..., M12, with escape release

Product Details

  • Weight
    2.76900272 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • Mission time
    20 y
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • PFHD
    3.1 x 10⁻⁹
  • Repeat accuracy R
    10 %
  • Switching delay from state change
    max.400 ms
  • Performance Level
    PL e
  • Input voltage
    15 ... 27,6 V DC
  • Discrepancy time
    max.10 ms
  • Turn-on time
    400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    UB-1,5V ... UB V DC
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching current
    1 ... 200 mA
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Safety class
    III
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Connection rating
    11 W
  • Fusing
    0,25 ... 8 A
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Current consumption
    80 mA
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Locking force Fmax
    6500 N
  • Guard locking principle
    Closed-circuit current principle
  • Mechanical life
    1 x 10⁶
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Approach speed
    max.20 m/min
  • Switching frequency
    max.0,5 Hz
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Degree of freedom X
    ±5 mm
  • Weight
    1 kg
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Ready delay
    10 s
  • Housing material
    Stainless steel
  • Degree of freedom Y
    ±5 mm
  • Installation orientation
    Any (Preferably head downward)
  • Degree of freedom Z
    ±4 mm
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 113965 on MQ Automation is $1,164.06. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;Indication of the door position by LED;Teach-in input;Escape release, 75 mm long;Approach direction A (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

113965 Euchner

$1,164.06

Your price can be lower.
Log in or Create account to check your discount

Stock:

11

Select Qty:

$1,164.06

$1,164.06 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 113965 with other products

Weight

Series

Product Class

Mission time

Category

For the approval acc. to ...

PFHD

Repeat accuracy R

Switching delay from stat...

Performance Level

Input voltage

Discrepancy time

Turn-on time

Risk time according to EN...

Off-state current Ir

Output voltage

Type of output

Switching current

Extension of risk time ac...

Switching load

Connecting cable

Safety class

Degree of contamination (...

Solenoid duty cycle

EMC protection requiremen...

Connection rating

Fusing

Utilization category acc....

Current consumption

Solenoid operating voltag...

Operating voltage DC

Locking force FZh

Locking force Fmax

Guard locking principle

Mechanical life

Shock and vibration resis...

Approach speed

Switching frequency

Connection

Degree of freedom X

Degree of protection

Ready delay

Housing material

Degree of freedom Y

Installation orientation

Degree of freedom Z

Ambient temperature

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

113965
11 in stock
113965
Euchner

113965 Euchner - Non-contact safety switch CET-AR-..., M12, with escape release

Weight2.76900272 lb

SeriesCET-AR

Product ClassSafety System

Mission time20 y

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

PFHD3.1 x 10⁻⁹

Repeat accuracy R10 %

Switching delay from state changemax.400 ms

Performance LevelPL e

Input voltage15 ... 27,6 V DC

Discrepancy timemax.10 ms

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

Off-state current Irmax.0,25 mA

Output voltageUB-1,5V ... UB V DC

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 200 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (For altern...

Connecting cable30V DC, 2A (For UL requirem...

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating11 W

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Current consumption80 mA

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Operating voltage DC24 V DC -15% ... 10%

Locking force FZh5000 N (FZH = FMAX/1.3)

Locking force Fmax6500 N

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Degree of freedom X±5 mm

Degree of protectionIP67 (Screwed tight plug co...

Ready delay10 s

Housing materialStainless steel

Degree of freedom Y±5 mm

Installation orientationAny (Preferably head downwa...

Degree of freedom Z±4 mm

Ambient temperature-20 ... 55 °C

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

PFHD4.1 x 10 ⁻⁹

Repeat accuracy R10 %

Switching delay from state change-

Performance LevelPL e

Input voltage-

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Type of outputp-switching, short circuit-p...

Switching current1 ... 50 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Switching load24V DC, class 2 (Alternativ...

Connecting cable-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5 and...

Degree of freedom X-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ready delay8 s

Housing materialDie-cast zinc

Degree of freedom Y-

Installation orientationAny

Degree of freedom Z-

Ambient temperature-20 ... +55 °C

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

PFHD4.1 x 10 ⁻⁹

Repeat accuracy R10 %

Switching delay from state change-

Performance LevelPL e

Input voltage-

Discrepancy timemax.10 ms In acc. with EN ...

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Type of output2 semiconductor outputs, p-s...

Switching current1 ... 150 mA

Extension of risk time according to EN 60947-5-3 per device-

Switching load24V DC, class 2 (Alternativ...

Connecting cable-

Safety classIII

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Current consumption40 mA

Solenoid operating voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh-

Locking force Fmax-

Guard locking principle-

Mechanical life1 x 10⁶

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Switching frequencymax.0,5 Hz

Connection2 plug connectors M12, 5-pin

Degree of freedom X-

Degree of protectionIP65 (Screwed tight plug co...

Ready delaymax.1 s

Housing materialFiber glass reinforced therm...

Degree of freedom Y-

Installation orientationDoor hinge DIN right

Degree of freedom Z-

Ambient temperature-20 ... +55 °C

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 113965?
The price of 113965 on MQ Automation is $1,164.06. Order now.

Out if stock but available for backorder.

113965 Euchner - Non-contact safety switch CET-AR-..., M12, with escape release

What can I help you find today?

Recommended parts