113609 Euchner - Non-contact safety switch CET-AR-..., M12
Product Details
- Weight 2.79104892 lb
- Series CET-AR
- Product Class Safety System
- Mission time 20 y
- PFHD 3.1 x 10⁻⁹
- Performance Level PL e
- Category 4
- Repeat accuracy R 10 %
- For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
- Risk time according to EN 60947-5-3 max.400 ms
- Discrepancy time max.10 ms
- Switching delay from state change max.400 ms
- Turn-on time 400 ms
- Off-state current Ir max.0,25 mA
- Output voltage UB-1,5V ... UB V DC
- Switching current 1 ... 200 mA
- Type of output 2 semiconductor outputs, p-switching, short circuit-proof
- Extension of risk time according to EN 60947-5-3 per device max.5 ms
- Switching load 24V DC, class 2 (For alternatives see operating instructions)
- Safety class III
- Connecting cable 30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
- Operating voltage DC 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
- Degree of contamination (external, according to EN 60947-1) 3
- Locking force FZh 5000 N (FZH = FMAX/1.3)
- Connection 2 plug connectors M12, 5 and 8-pin
- Solenoid duty cycle 100 %
- Installation orientation Any (Preferably head downward)
- EMC protection requirements In acc. with EN IEC 60947-5-3
- Connection rating 11 W
- Degree of protection IP67 (Screwed tight plug connector/mating component)
- Solenoid operating voltage DC 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
- Fusing 0,5 ... 8 A
- Utilization category acc. to EN 60947-5-2 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
- Current consumption 80 mA
- Locking force Fmax 6500 N
- Guard locking principle Open-circuit current principle
- Approach speed max.20 m/min
- Ambient temperature -20 ... 55 °C
- Weight 1 kg
- Mechanical life 1 x 10⁶
- Switching frequency max.0,5 Hz
- Ready delay 10 s
- Housing material Stainless steel
- Degree of freedom Z ±4 mm
- Shock and vibration resistance In acc. with EN 60947-5-3
- Degree of freedom Y ±5 mm
- Degree of freedom X ±5 mm
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 113609 on MQ Automation is $872.40. Order now.
About the product
Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Door monitoring output;Indication of the door position by LED;Approach direction A (delivery state)
Manufacturer warranty
113609 Euchner
$872.40
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$872.40
$872.40 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 113609 with other products
Weight
Series
Product Class
Mission time
PFHD
Performance Level
Category
Repeat accuracy R
For the approval acc. to ...
Risk time according to EN...
Discrepancy time
Switching delay from stat...
Turn-on time
Off-state current Ir
Output voltage
Switching current
Type of output
Extension of risk time ac...
Switching load
Safety class
Connecting cable
Operating voltage DC
Degree of contamination (...
Locking force FZh
Connection
Solenoid duty cycle
Installation orientation
EMC protection requiremen...
Connection rating
Degree of protection
Solenoid operating voltag...
Fusing
Utilization category acc....
Current consumption
Locking force Fmax
Guard locking principle
Approach speed
Ambient temperature
Mechanical life
Switching frequency
Ready delay
Housing material
Degree of freedom Z
Shock and vibration resis...
Degree of freedom Y
Degree of freedom X
Additional feature
Rated impulse withstand v...
Rated insulation voltage ...
Test pulses
Test-pulse interval
Actuating force
Extraction force
Overtravel
Retention force
B10D
Version
Operating current
Switching element
Detent mechanism
Operating voltage
Selected product
Weight2.79104892 lb
SeriesCET-AR
Product ClassSafety System
Mission time20 y
PFHD3.1 x 10⁻⁹
Performance LevelPL e
Category4
Repeat accuracy R10 %
For the approval acc. to UL the following appliesOperation only with UL class...
Risk time according to EN 60947-5-3max.400 ms
Discrepancy timemax.10 ms
Switching delay from state changemax.400 ms
Turn-on time400 ms
Off-state current Irmax.0,25 mA
Output voltageUB-1,5V ... UB V DC
Switching current1 ... 200 mA
Type of output2 semiconductor outputs, p-s...
Extension of risk time according to EN 60947-5-3 per devicemax.5 ms
Switching load24V DC, class 2 (For altern...
Safety classIII
Connecting cable30V DC, 2A (For UL requirem...
Operating voltage DC24 V DC -15% ... 15% Rev...
Degree of contamination (external, according to EN 60947-1)3
Locking force FZh5000 N (FZH = FMAX/1.3)
Connection2 plug connectors M12, 5 and...
Solenoid duty cycle100 %
Installation orientationAny (Preferably head downwa...
EMC protection requirementsIn acc. with EN IEC 60947-5-...
Connection rating11 W
Degree of protectionIP67 (Screwed tight plug co...
Solenoid operating voltage DC24 V DC -15% ... +10% Re...
Fusing0,5 ... 8 A
Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...
Current consumption80 mA
Locking force Fmax6500 N
Guard locking principleOpen-circuit current princip...
Approach speedmax.20 m/min
Ambient temperature-20 ... 55 °C
Mechanical life1 x 10⁶
Switching frequencymax.0,5 Hz
Ready delay10 s
Housing materialStainless steel
Degree of freedom Z±4 mm
Shock and vibration resistanceIn acc. with EN 60947-5-3
Degree of freedom Y±5 mm
Degree of freedom X±5 mm
Additional feature-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Test pulses-
Test-pulse interval-
Actuating force-
Extraction force-
Overtravel-
Retention force-
B10D-
Version-
Operating current-
Switching element-
Detent mechanism-
Operating voltage-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 113609?
The price of 113609 on MQ Automation is $872.40. Order now.
Out if stock but available for backorder.
113609 Euchner - Non-contact safety switch CET-AR-..., M12
Similar products from: Safety Proximity Sensors
What can I help you find today?