113294 Euchner Safety Proximity Sensors
Part#:113294
Alt. Part#:CES-A-LNN-10V-113294
Manufacturer:Euchner
Category:Safety Proximity Sensors
Product Lifecycle:Active
Product description
113294 Euchner - Read head CES-A-LNN-...hard-wired encapsulated cable 10 m, PVC
Product Details
- Weight 0.77602624 lb
- Series CES read heads
- Product Class Safety System
- Connecting cable PVC, length 10m, Ø 4.6 mm, with crimped ferrules
- Power supply Via evaluation unit
- LED indicator White: valid actuator detected
- Cable length max.25 m
- Tightening torque max.1 Nm
- Method of operation Inductive
- Installation orientation Any
- Connection Hard-wired encapsulated connection cable
- Ambient temperature -25 ... 70 °C
- Degree of protection IP67
- Housing material Reinforced thermoplastic (PBT), fully encapsulated
- Weight 0,025 kg ((Without connection cable))
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 113294 on MQ Automation is $80.69. Order now.
About the product
Cube-shaped design 42 x 25 mm;Mounting compatible with series CES-A-LNA/LCA;LED for indicating the door position;Hard-wired encapsulated cable, PVC;Cable length 10 m
Manufacturer warranty
113294 Euchner
$80.69
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$80.69
$80.69 each
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Manufacturer warranty
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 113294 with other products
Weight
Series
Product Class
Connecting cable
Power supply
LED indicator
Cable length
Tightening torque
Method of operation
Installation orientation
Connection
Ambient temperature
Degree of protection
Housing material
Switching hysteresis
Assured operating distanc...
Assured release distance ...
PFHD
Operating distance
Mission time
Performance Level
Category
For the approval acc. to ...
Repeat accuracy R
Discrepancy time
Off-state current Ir
Utilization category acc....
Rated conditional short-c...
Test pulses
Test-pulse interval
Output voltage
Switching current
Turn-on time
Risk time according to EN...
Type of output
Fusing
Rated impulse withstand v...
Rated insulation voltage ...
Degree of contamination (...
Safety class
EMC protection requiremen...
Extension of risk time ac...
Current consumption
Mounting distance
Operating voltage DC
Switching frequency
Ready delay
Cable ambient temperature...
Mounting method
Static bending radius
Shock and vibration resis...
Cable ambient temperature...
Dynamic bending radius
Overtravel
B10D
Connection cross-section
Solenoid duty cycle
Connection rating
Switching voltage
Short circuit protection ...
Solenoid operating voltag...
Thermal rated current Ith
Insertion depth
Utilization category acc....
Actuating force
Retention force
Extraction force
Locking force FZh
Approach speed
Guard locking principle
Locking force Fmax
Actuation frequency
Number of door position N...
Number of guard lock moni...
Number of door position N...
Switching principle
Mechanical life
Contact material
Selected product

113294
Euchner
113294 Euchner - Read head CES-A-LNN-...hard-wired encapsulated cable 10 m, PVC
Weight0.77602624 lb
SeriesCES read heads
Product ClassSafety System
Connecting cablePVC, length 10m, Ø 4.6 mm, w...
Power supplyVia evaluation unit
LED indicatorWhite: valid actuator detect...
Cable lengthmax.25 m
Tightening torquemax.1 Nm
Method of operationInductive
Installation orientationAny
ConnectionHard-wired encapsulated conn...
Ambient temperature-25 ... 70 °C
Degree of protectionIP67
Housing materialReinforced thermoplastic (PB...
Switching hysteresis-
Assured operating distance Sao-
Assured release distance Sar-
PFHD-
Operating distance-
Mission time-
Performance Level-
Category-
For the approval acc. to UL the following applies-
Repeat accuracy R-
Discrepancy time-
Off-state current Ir-
Utilization category acc. to EN 60947-5-2-
Rated conditional short-circuit current-
Test pulses-
Test-pulse interval-
Output voltage-
Switching current-
Turn-on time-
Risk time according to EN 60947-5-3-
Type of output-
Fusing-
Rated impulse withstand voltage Uimp-
Rated insulation voltage Ui-
Degree of contamination (external, according to EN 60947-1)-
Safety class-
EMC protection requirements-
Extension of risk time according to EN 60947-5-3 per device-
Current consumption-
Mounting distance-
Operating voltage DC-
Switching frequency-
Ready delay-
Cable ambient temperature (dynamic)-
Mounting method-
Static bending radius-
Shock and vibration resistance-
Cable ambient temperature (static)-
Dynamic bending radius-
Overtravel-
B10D-
Connection cross-section-
Solenoid duty cycle-
Connection rating-
Switching voltage-
Short circuit protection according to IEC 60269-1-
Solenoid operating voltage-
Thermal rated current Ith-
Insertion depth-
Utilization category acc. to EN 60947-5-1-
Actuating force-
Retention force-
Extraction force-
Locking force FZh-
Approach speed-
Guard locking principle-
Locking force Fmax-
Actuation frequency-
Number of door position NO contacts-
Number of guard lock monitoring positively driven contacts-
Number of door position NC contacts-
Switching principle-
Mechanical life-
Contact material-
About the manufacturer

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.
Recently viewed products
Relevant products
FAQ
What is the price of 113294?
The price of 113294 on MQ Automation is $80.69. Order now.
Out if stock but available for backorder.
113294 Euchner - Read head CES-A-LNN-...hard-wired encapsulated cable 10 m, PVC
Similar products from: Safety Proximity Sensors
What can I help you find today?