113139 Euchner Safety Proximity Sensors

113139 on MQ Automation
Euchner
  • 113139
  • 113139
  • 113139

Part#:113139

Alt. Part#:CET3-AR-CRA-AH-50X-SG-C2290-113139

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

113139 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden) (3 m)

Product Details

  • Weight
    3.2297683 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Mission time
    20 y
  • Performance Level
    PL e
  • Category
    4
  • Repeat accuracy R
    10 %
  • Turn-on time
    400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Discrepancy time
    max.10 ms
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Switching delay from state change
    max.400 ms
  • Input voltage
    0 ... 1 V DC
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    UB-1,5V ... UB V DC
  • Switching current
    1 ... 200 mA
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Safety class
    III
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Solenoid duty cycle
    100 %
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Connection rating
    11 W
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Fusing
    0,25 ... 8 A
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Current consumption
    80 mA
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Operating voltage DC
    24 V DC -15% ... 10%
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Locking force Fmax
    6500 N
  • Guard locking principle
    Closed-circuit current principle
  • Approach speed
    max.20 m/min
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Switching frequency
    max.0,5 Hz
  • Ready delay
    10 s
  • Installation orientation
    Any (Preferably head downward)
  • Mechanical life
    1 x 10⁶
  • Weight
    1 kg
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Die-cast aluminum
  • Degree of freedom Y
    ±5 mm
  • Degree of freedom X
    ±5 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Degree of freedom Z
    ±4 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 113139 on MQ Automation is $1,082.06. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Unicode;Door monitoring output;Indication of the door position by LED;Teach-in input;Wire front release (bowden), 3 m, automatic return;Approach direction A (delivery state)


Manufacturer warranty

113139 Euchner

$1,082.06

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,082.06

$1,082.06 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 113139 with other products

Weight

Series

Product Class

PFHD

Mission time

Performance Level

Category

Repeat accuracy R

Turn-on time

Risk time according to EN...

Discrepancy time

For the approval acc. to ...

Switching delay from stat...

Input voltage

Off-state current Ir

Output voltage

Switching current

Extension of risk time ac...

Connecting cable

Safety class

Switching load

Degree of contamination (...

Solenoid duty cycle

Type of output

Connection rating

EMC protection requiremen...

Fusing

Solenoid operating voltag...

Current consumption

Utilization category acc....

Operating voltage DC

Locking force FZh

Locking force Fmax

Guard locking principle

Approach speed

Connection

Switching frequency

Ready delay

Installation orientation

Mechanical life

Degree of protection

Ambient temperature

Housing material

Degree of freedom Y

Degree of freedom X

Shock and vibration resis...

Degree of freedom Z

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

113139
0 in stock
113139
Euchner

113139 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden) (3 m)

Weight3.2297683 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Repeat accuracy R10 %

Turn-on time400 ms

Risk time according to EN 60947-5-3max.400 ms

Discrepancy timemax.10 ms

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state changemax.400 ms

Input voltage0 ... 1 V DC

Off-state current Irmax.0,25 mA

Output voltageUB-1,5V ... UB V DC

Switching current1 ... 200 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Connecting cable30V DC, 2A (For UL requirem...

Safety classIII

Switching load24V DC, class 2 (For altern...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Type of output2 semiconductor outputs, p-s...

Connection rating11 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption80 mA

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 10%

Locking force FZh5000 N (FZH = FMAX/1.3)

Locking force Fmax6500 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Ready delay10 s

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Degree of protectionIP67 (Screwed tight plug co...

Ambient temperature-20 ... 55 °C

Housing materialDie-cast aluminum

Degree of freedom Y±5 mm

Degree of freedom X±5 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom Z±4 mm

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Repeat accuracy R10 %

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Input voltage-

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Switching current1 ... 50 mA

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Connecting cable-

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle100 %

Type of outputp-switching, short circuit-p...

Connection rating6 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Locking force Fmax3900 N

Guard locking principleClosed-circuit current princ...

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Ready delay8 s

Installation orientationAny

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Degree of freedom Y-

Degree of freedom X-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom Z-

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

Repeat accuracy R10 %

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

For the approval acc. to UL the following appliesOperation only with UL class...

Switching delay from state change-

Input voltage-

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Switching current1 ... 150 mA

Extension of risk time according to EN 60947-5-3 per device-

Connecting cable-

Safety classIII

Switching load24V DC, class 2 (Alternativ...

Degree of contamination (external, according to EN 60947-1)3

Solenoid duty cycle-

Type of output2 semiconductor outputs, p-s...

Connection rating1 W

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Current consumption40 mA

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force FZh-

Locking force Fmax-

Guard locking principle-

Approach speedmax.20 m/min

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Degree of freedom Y-

Degree of freedom X-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom Z-

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 113139?
The price of 113139 on MQ Automation is $1,082.06. Order now.

Out if stock but available for backorder.

113139 Euchner - Non-contact safety switch CET-AR-..., M12, with wire front release (bowden) (3 m)

What can I help you find today?

Recommended parts