Product description

113081 Euchner - Non-contact safety switch CET-AR-..., M12

Product Details

  • Weight
    2.54854072 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • Performance Level
    PL e
  • PFHD
    3.1 x 10⁻⁹
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Mission time
    20 y
  • Repeat accuracy R
    10 %
  • Input voltage
    15 ... 27,6 V DC
  • Switching delay from state change
    max.400 ms
  • Turn-on time
    400 ms
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Discrepancy time
    max.10 ms
  • Switching current
    1 ... 200 mA
  • Off-state current Ir
    max.0,25 mA
  • Output voltage
    UB-1,5V ... UB V DC
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Safety class
    III
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Fusing
    0,25 ... 8 A
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Degree of contamination (external, according to EN 60947-1)
    3
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Solenoid duty cycle
    100 %
  • Current consumption
    450 mA
  • Connection rating
    11 W
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Locking force Fmax
    6500 N
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Approach speed
    max.20 m/min
  • Guard locking principle
    Open-circuit current principle
  • Switching frequency
    max.0,5 Hz
  • Ready delay
    10 s
  • Degree of freedom Y
    ±5 mm
  • Installation orientation
    Any (Preferably head downward)
  • Mechanical life
    1 x 10⁶
  • Degree of freedom Z
    ±4 mm
  • Weight
    1 kg
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Stainless steel
  • Degree of freedom X
    ±5 mm
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Shock and vibration resistance
    In acc. with EN 60947-5-3

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 113081 on MQ Automation is $913.07. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Door monitoring output;Indication of the door position by LED;Feedback loop / start button;Approach direction A (delivery state)


This item can ship in 3-5 days!

Manufacturer warranty

113081 Euchner

$913.07

Your price can be lower.
Log in or Create account to check your discount

Stock:

1

Select Qty:

$913.07

$913.07 each

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 113081 with other products

Weight

Series

Product Class

Performance Level

PFHD

Category

For the approval acc. to ...

Mission time

Repeat accuracy R

Input voltage

Switching delay from stat...

Turn-on time

Type of output

Risk time according to EN...

Discrepancy time

Switching current

Off-state current Ir

Output voltage

Switching load

Extension of risk time ac...

Safety class

Connecting cable

Utilization category acc....

Fusing

Solenoid operating voltag...

Degree of contamination (...

EMC protection requiremen...

Solenoid duty cycle

Current consumption

Connection rating

Operating voltage DC

Locking force Fmax

Locking force FZh

Connection

Approach speed

Guard locking principle

Switching frequency

Ready delay

Degree of freedom Y

Installation orientation

Mechanical life

Degree of freedom Z

Ambient temperature

Housing material

Degree of freedom X

Degree of protection

Shock and vibration resis...

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

113081
1 in stock
113081
Euchner

113081 Euchner - Non-contact safety switch CET-AR-..., M12

Weight2.54854072 lb

SeriesCET-AR

Product ClassSafety System

Performance LevelPL e

PFHD3.1 x 10⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Mission time20 y

Repeat accuracy R10 %

Input voltage15 ... 27,6 V DC

Switching delay from state changemax.400 ms

Turn-on time400 ms

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3max.400 ms

Discrepancy timemax.10 ms

Switching current1 ... 200 mA

Off-state current Irmax.0,25 mA

Output voltageUB-1,5V ... UB V DC

Switching load24V DC, class 2 (For altern...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Connecting cable30V DC, 2A (For UL requirem...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Current consumption450 mA

Connection rating11 W

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax6500 N

Locking force FZh5000 N (FZH = FMAX/1.3)

Connection2 plug connectors M12, 5 and...

Approach speedmax.20 m/min

Guard locking principleOpen-circuit current princip...

Switching frequencymax.0,5 Hz

Ready delay10 s

Degree of freedom Y±5 mm

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Degree of freedom Z±4 mm

Ambient temperature-20 ... 55 °C

Housing materialStainless steel

Degree of freedom X±5 mm

Degree of protectionIP67 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Mission time20 y

Repeat accuracy R10 %

Input voltage-

Switching delay from state change-

Turn-on timemax.400 ms

Type of outputp-switching, short circuit-p...

Risk time according to EN 60947-5-3max.260 ms

Discrepancy timemax.10 ms In acc. with EN ...

Switching current1 ... 50 mA

Off-state current Irmax.0,25 mA

Output voltage0,8xUB ... UB V DC

Switching load24V DC, class 2 (Alternativ...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Connecting cable-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle100 %

Current consumption40 mA

Connection rating6 W

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax3900 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Approach speedmax.20 m/min

Guard locking principleClosed-circuit current princ...

Switching frequencymax.0,5 Hz

Ready delay8 s

Degree of freedom Y-

Installation orientationAny

Mechanical life1 x 10⁶

Degree of freedom Z-

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

Degree of freedom X-

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Performance LevelPL e

PFHD4.1 x 10 ⁻⁹

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Mission time20 y

Repeat accuracy R10 %

Input voltage-

Switching delay from state change-

Turn-on timemax.400 ms

Type of output2 semiconductor outputs, p-s...

Risk time according to EN 60947-5-3-

Discrepancy timemax.10 ms In acc. with EN ...

Switching current1 ... 150 mA

Off-state current Irmax.0,25 mA

Output voltage0 ... 1 V DC

Switching load24V DC, class 2 (Alternativ...

Extension of risk time according to EN 60947-5-3 per device-

Safety classIII

Connecting cable-

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Fusing0,25 ... 8 A

Solenoid operating voltage DC-

Degree of contamination (external, according to EN 60947-1)3

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Solenoid duty cycle-

Current consumption40 mA

Connection rating1 W

Operating voltage DC24 V DC -15% ... 15% Rev...

Locking force Fmax-

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Approach speedmax.20 m/min

Guard locking principle-

Switching frequencymax.0,5 Hz

Ready delaymax.1 s

Degree of freedom Y-

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Degree of freedom Z-

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

Degree of freedom X-

Degree of protectionIP65 (Screwed tight plug co...

Shock and vibration resistanceIn acc. with EN 60947-5-3

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 113081?
The price of 113081 on MQ Automation is $913.07. Order now.

Out if stock but available for backorder.

113081 Euchner - Non-contact safety switch CET-AR-..., M12

What can I help you find today?

Recommended parts