112992 Euchner Safety Proximity Sensors

112992 on MQ Automation
Euchner
  • 112992
  • 112992
  • 112992

Part#:112992

Alt. Part#:CET3-AR-CRA-CH-50S-SG-112992

Manufacturer:Euchner

Category:Safety Proximity Sensors

Product Lifecycle:Active

Product description

112992 Euchner - Non-contact safety switch CET-AR-..., M12

Product Details

  • Weight
    2.77341196 lb
  • Series
    CET-AR
  • Product Class
    Safety System
  • PFHD
    3.1 x 10⁻⁹
  • Mission time
    20 y
  • Performance Level
    PL e
  • Category
    4
  • For the approval acc. to UL the following applies
    Operation only with UL class 2 power supply, or equivalent measures see operating instructions
  • Repeat accuracy R
    10 %
  • Turn-on time
    400 ms
  • Input voltage
    15 ... 27,6 V DC
  • Discrepancy time
    max.10 ms
  • Off-state current Ir
    max.0,25 mA
  • Switching delay from state change
    max.400 ms
  • Risk time according to EN 60947-5-3
    max.400 ms
  • Output voltage
    0 ... 1 V DC
  • Switching current
    1 ... 200 mA
  • Type of output
    2 semiconductor outputs, p-switching, short circuit-proof
  • Switching load
    24V DC, class 2 (For alternatives see operating instructions)
  • Extension of risk time according to EN 60947-5-3 per device
    max.5 ms
  • Safety class
    III
  • Connecting cable
    30V DC, 2A (For UL requirement UL category code (CYJV/CYJV7))
  • EMC protection requirements
    In acc. with EN IEC 60947-5-3
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Fusing
    0,25 ... 8 A
  • Solenoid duty cycle
    100 %
  • Connection rating
    11 W
  • Current consumption
    80 mA
  • Solenoid operating voltage DC
    24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Operating voltage DC
    24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
  • Guard locking principle
    Closed-circuit current principle
  • Locking force Fmax
    6500 N
  • Locking force FZh
    5000 N (FZH = FMAX/1.3)
  • Connection
    2 plug connectors M12, 5 and 8-pin
  • Switching frequency
    max.0,5 Hz
  • Approach speed
    max.20 m/min
  • Ready delay
    10 s
  • Installation orientation
    Any (Preferably head downward)
  • Weight
    1 kg
  • Mechanical life
    1 x 10⁶
  • Degree of protection
    IP67 (Screwed tight plug connector/mating component)
  • Degree of freedom Y
    ±5 mm
  • Housing material
    Stainless steel
  • Degree of freedom Z
    ±4 mm
  • Shock and vibration resistance
    In acc. with EN 60947-5-3
  • Degree of freedom X
    ±5 mm
  • Ambient temperature
    -20 ... 55 °C

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 112992 on MQ Automation is $913.07. Order now.


About the product

Safety switch with guard locking and integrated evaluation electronics;Locking force up to 6500 N;Up to 20 switches in series;Short circuit monitoring;2 safety outputs (semiconductor outputs);Category 4 / PL e according to EN ISO 13849-1;With 2 plug connectors M12;Multicode;Door monitoring output;Indication of the door position by LED;Feedback loop / start button;Approach direction A (delivery state)


Manufacturer warranty

112992 Euchner

$913.07

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$913.07

$913.07 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 112992 with other products

Weight

Series

Product Class

PFHD

Mission time

Performance Level

Category

For the approval acc. to ...

Repeat accuracy R

Turn-on time

Input voltage

Discrepancy time

Off-state current Ir

Switching delay from stat...

Risk time according to EN...

Output voltage

Switching current

Type of output

Switching load

Extension of risk time ac...

Safety class

Connecting cable

EMC protection requiremen...

Degree of contamination (...

Fusing

Solenoid duty cycle

Connection rating

Current consumption

Solenoid operating voltag...

Operating voltage DC

Utilization category acc....

Guard locking principle

Locking force Fmax

Locking force FZh

Connection

Switching frequency

Approach speed

Ready delay

Installation orientation

Mechanical life

Degree of protection

Degree of freedom Y

Housing material

Degree of freedom Z

Shock and vibration resis...

Degree of freedom X

Ambient temperature

Additional feature

Rated impulse withstand v...

Rated insulation voltage ...

Test pulses

Test-pulse interval

Actuating force

Extraction force

Overtravel

Retention force

B10D

Version

Operating current

Switching element

Detent mechanism

Operating voltage

Selected product

112992
0 in stock
112992
Euchner

112992 Euchner - Non-contact safety switch CET-AR-..., M12

Weight2.77341196 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on time400 ms

Input voltage15 ... 27,6 V DC

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Switching delay from state changemax.400 ms

Risk time according to EN 60947-5-3max.400 ms

Output voltage0 ... 1 V DC

Switching current1 ... 200 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (For altern...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Connecting cable30V DC, 2A (For UL requirem...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Fusing0,25 ... 8 A

Solenoid duty cycle100 %

Connection rating11 W

Current consumption80 mA

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Locking force Fmax6500 N

Locking force FZh5000 N (FZH = FMAX/1.3)

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Ready delay10 s

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Degree of protectionIP67 (Screwed tight plug co...

Degree of freedom Y±5 mm

Housing materialStainless steel

Degree of freedom Z±4 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom X±5 mm

Ambient temperature-20 ... 55 °C

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Input voltage-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Switching delay from state change-

Risk time according to EN 60947-5-3max.260 ms

Output voltage0,8xUB ... UB V DC

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching load24V DC, class 2 (Alternativ...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Connecting cable-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Fusing0,25 ... 8 A

Solenoid duty cycle100 %

Connection rating6 W

Current consumption40 mA

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Locking force Fmax3900 N

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Ready delay8 s

Installation orientationAny

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Degree of freedom Y-

Housing materialDie-cast zinc

Degree of freedom Z-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom X-

Ambient temperature-20 ... +55 °C

Additional featureEscape release actuated by p...

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.1,0 ms (Applies for a l...

Test-pulse intervalmin.140 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force20 N

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

PFHD4.1 x 10 ⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on timemax.400 ms

Input voltage-

Discrepancy timemax.10 ms In acc. with EN ...

Off-state current Irmax.0,25 mA

Switching delay from state change-

Risk time according to EN 60947-5-3-

Output voltage0 ... 1 V DC

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (Alternativ...

Extension of risk time according to EN 60947-5-3 per device-

Safety classIII

Connecting cable-

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Fusing0,25 ... 8 A

Solenoid duty cycle-

Connection rating1 W

Current consumption40 mA

Solenoid operating voltage DC-

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Guard locking principle-

Locking force Fmax-

Locking force FZh-

Connection2 plug connectors M12, 5-pin

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Ready delaymax.1 s

Installation orientationDoor hinge DIN right

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Degree of freedom Y-

Housing materialFiber glass reinforced therm...

Degree of freedom Z-

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom X-

Ambient temperature-20 ... +55 °C

Additional feature-

Rated impulse withstand voltage Uimp0,5 kV

Rated insulation voltage Ui50 V

Test pulsesmax.0,3 ms (Applies for a l...

Test-pulse intervalmin.100 ms

Actuating force10 N

Extraction force20 N

Overtravel5 mm

Retention force-

B10D0,13 x 10⁶

VersionEmergency stop

Operating current1 ... 100 mA

Switching element2 pos. driven NC

Detent mechanismSnap-in bolt

Operating voltage5 ... 24 V

112992
0 in stock
112992
Euchner

112992 Euchner - Non-contact safety switch CET-AR-..., M12

Weight2.77341196 lb

SeriesCET-AR

Product ClassSafety System

PFHD3.1 x 10⁻⁹

Mission time20 y

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R10 %

Turn-on time400 ms

Input voltage15 ... 27,6 V DC

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Switching delay from state changemax.400 ms

Risk time according to EN 60947-5-3max.400 ms

Output voltage0 ... 1 V DC

Switching current1 ... 200 mA

Type of output2 semiconductor outputs, p-s...

Switching load24V DC, class 2 (For altern...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Safety classIII

Connecting cable30V DC, 2A (For UL requirem...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Degree of contamination (external, according to EN 60947-1)3

Fusing0,25 ... 8 A

Solenoid duty cycle100 %

Connection rating11 W

Current consumption80 mA

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Operating voltage DC24 V DC -15% ... 15% Rev...

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Guard locking principleClosed-circuit current princ...

Locking force Fmax6500 N

Locking force FZh5000 N (FZH = FMAX/1.3)

Connection2 plug connectors M12, 5 and...

Switching frequencymax.0,5 Hz

Approach speedmax.20 m/min

Ready delay10 s

Installation orientationAny (Preferably head downwa...

Mechanical life1 x 10⁶

Degree of protectionIP67 (Screwed tight plug co...

Degree of freedom Y±5 mm

Housing materialStainless steel

Degree of freedom Z±4 mm

Shock and vibration resistanceIn acc. with EN 60947-5-3

Degree of freedom X±5 mm

Ambient temperature-20 ... 55 °C

Additional feature-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Test pulses-

Test-pulse interval-

Actuating force-

Extraction force-

Overtravel-

Retention force-

B10D-

Version-

Operating current-

Switching element-

Detent mechanism-

Operating voltage-

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

FAQ

What is the price of 112992?
The price of 112992 on MQ Automation is $913.07. Order now.

Out if stock but available for backorder.

112992 Euchner - Non-contact safety switch CET-AR-..., M12

What can I help you find today?

Recommended parts