111230 Euchner Electronic Key Systems

111230 on MQ Automation
Euchner
  • 111230
  • 111230
  • 111230

Part#:111230

Alt. Part#:EKS-A-IPB-G01-ST05/02

Manufacturer:Euchner

Category:Electronic Key Systems

Product Lifecycle:Active

Product description

111230 Euchner - Electronic-Key adapter EKS Light compact (supports only operating state 0)

Product Details

  • Weight
    0.39242236 lb
  • Series
    EKS Light
  • Product Class
    Electronic-Key-System
  • Switching current
    1 ... 10 ... 50 mA High signal
  • Switching voltage
    UB-2 ... UB V (High signal)
  • Ambient temperature
    -20 ... 70 °C
  • Mounting method
    On the front
  • Housing material
    PA6-GF30 gray/black
  • Data interface
    4-bit parallel plus strobe, binary coded via High/Low level
  • Current consumption
    max.70 mA
  • LED indicator
    Operational
  • Mounting cut-out
    33x68 mm
  • Connection cross-section
    0,14 ... 1,5 mm²
  • Operating voltage DC
    9 ... 24 ... 28 V DC (For use and operation as per the UL requirements, a power supply with the feature "for use in class 2 circuits" must be used.)
  • Degree of protection
    IP67

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 111230 on MQ Automation is $475.14. Order now.


About the product

Electronic-Key adapter with 4-bit parallel interface;Simple connection;Read-only system;Electronic-Key adapter and evaluation electronics in one housing;Reliable retention of the Electronic-Key, even if there is heavy vibration;Internal evaluation of the data from the Electronic-Key;Output of the access level via 4-bit parallel interface;Only operating state 0;Connection to PLC


Manufacturer warranty

111230 Euchner

$475.14

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$475.14

$475.14 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 111230 with other products

Weight

Series

Product Class

Switching current

Switching voltage

Ambient temperature

Mounting method

Housing material

Data interface

Current consumption

LED indicator

Mounting cut-out

Connection cross-section

Operating voltage DC

Degree of protection

Additional feature

Utilization category acc....

Utilization category acc....

Connection

Number of read heads

Switching hysteresis

Assured operating distanc...

Assured release distance ...

PFHD

Operating distance

Mission time

Performance Level

Category

For the approval acc. to ...

Repeat accuracy R

Discrepancy time

Off-state current Ir

Rated conditional short-c...

Test pulses

Test-pulse interval

Output voltage

Turn-on time

Risk time according to EN...

Type of output

Fusing

Rated impulse withstand v...

Rated insulation voltage ...

Degree of contamination (...

Safety class

EMC protection requiremen...

Extension of risk time ac...

Tightening torque

Installation orientation

Mounting distance

Switching frequency

Ready delay

Cable ambient temperature...

Static bending radius

Shock and vibration resis...

Cable ambient temperature...

Dynamic bending radius

Selected product

111230
0 in stock
111230
Euchner

111230 Euchner - Electronic-Key adapter EKS Light compact (supports only operating state 0)

Weight0.39242236 lb

SeriesEKS Light

Product ClassElectronic-Key-System

Switching current1 ... 10 ... 50 mA High si...

Switching voltageU<sub>B</sub>-2 ... U<sub>B<...

Ambient temperature-20 ... 70 °C

Mounting methodOn the front

Housing materialPA6-GF30 gray/black

Data interface4-bit parallel plus strobe, ...

Current consumptionmax.70 mA

LED indicatorOperational

Mounting cut-out33x68 mm

Connection cross-section0,14 ... 1,5 mm²

Operating voltage DC9 ... 24 ... 28 V DC (For u...

Degree of protectionIP67

Additional feature-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-2-

Connection-

Number of read heads-

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Installation orientation-

Mounting distance-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

113645
1 in stock
113645
Euchner

113645 Euchner - Interface adapter EKS Light FSA modular (supports all operating states)

Weight0.46517482 lb

SeriesEKS Light

Product ClassElectronic-Key-System

Switching current1 ... 10 ... 50 mA High si...

Switching voltageU<sub>B</sub>-2 ... U<sub>B<...

Ambient temperature0 ... 55 °C

Mounting methodMounting rail 35mm according...

Housing materialPA6.6 gray

Data interface4-bit parallel plus strobe, ...

Current consumptionmax.70 mA

LED indicatorOperational

Mounting cut-out-

Connection cross-section0,14 ... 2,5 mm²

Operating voltage DC9 ... 24 ... 28 V DC (For u...

Degree of protection-

Additional feature35 Resistance in switched-...

Utilization category acc. to EN 60947-5-124V 50mA

Utilization category acc. to EN 60947-5-224V 50mA

ConnectionPlug-in screw terminal

Number of read headsmax.1

Switching hysteresis-

Assured operating distance Sao-

Assured release distance Sar-

PFHD-

Operating distance-

Mission time-

Performance Level-

Category-

For the approval acc. to UL the following applies-

Repeat accuracy R-

Discrepancy time-

Off-state current Ir-

Rated conditional short-circuit current-

Test pulses-

Test-pulse interval-

Output voltage-

Turn-on time-

Risk time according to EN 60947-5-3-

Type of output-

Fusing-

Rated impulse withstand voltage Uimp-

Rated insulation voltage Ui-

Degree of contamination (external, according to EN 60947-1)-

Safety class-

EMC protection requirements-

Extension of risk time according to EN 60947-5-3 per device-

Tightening torque-

Installation orientation-

Mounting distance-

Switching frequency-

Ready delay-

Cable ambient temperature (dynamic)-

Static bending radius-

Shock and vibration resistance-

Cable ambient temperature (static)-

Dynamic bending radius-

105748
2 in stock
105748
Euchner

105748 Euchner - Non-contact safety switch CES-AR-CL2-... , plug connector M12, PUR

Weight0.29100984 lb

SeriesCES-AR

Product ClassSafety System

Switching currentmax.50 mA

Switching voltage-

Ambient temperature-

Mounting methodSurface mounting on metal

Housing materialPlastic, PBT

Data interface-

Current consumptionmax.50 mA (Without taking i...

LED indicator-

Mounting cut-out-

Connection cross-section-

Operating voltage DC24 V DC 15% ... 15% Regu...

Degree of protectionIP67

Additional feature-

Utilization category acc. to EN 60947-5-1-

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

ConnectionConnection cable PUR, length...

Number of read heads-

Switching hysteresismin.1 mm

Assured operating distance Saomin.14 mm

Assured release distance Sarmax.60 mm

PFHD1.9 x 10⁻⁹

Operating distance19 mm

Mission time20

Performance LevelPL e

Category4

For the approval acc. to UL the following appliesOperation only with UL class...

Repeat accuracy R≤ 10

Discrepancy timemax.10 ms

Off-state current Irmax.0,25 mA

Rated conditional short-circuit current100 A

Test pulsesmax.1 ms (Applies for a loa...

Test-pulse intervalmin.140 ms

Output voltage0,8 x UB ... UB V DC

Turn-on timemax.400 ms

Risk time according to EN 60947-5-3max.260 ms

Type of outputp-switching, short circuit-p...

Fusing0,25 ... 8 A

Rated impulse withstand voltage Uimp1,5 kV

Rated insulation voltage Ui75 V

Degree of contamination (external, according to EN 60947-1)3

Safety classIII

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Tightening torquemax.1 Nm

Installation orientationAny

Mounting distancemin.120 mm

Switching frequencymax.1 Hz

Ready delay10 s

Cable ambient temperature (dynamic)-25 ... 65 °C

Static bending radius5 x cable diameter

Shock and vibration resistanceIn acc. with EN 60947-5-3

Cable ambient temperature (static)-25 ... 65 °C

Dynamic bending radius10 x cable diameter

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 111230?
The price of 111230 on MQ Automation is $475.14. Order now.

Out if stock but available for backorder.

111230 Euchner - Electronic-Key adapter EKS Light compact (supports only operating state 0)