110793 Euchner Safety Accessories

110793 on MQ Automation
Euchner
  • 110793
  • 110793
  • 110793

Part#:110793

Alt. Part#:MGB-L1-ARA-AA2A1-S1-L-110793

Manufacturer:Euchner

Category:Safety Accessories

Product Lifecycle:Active

Product description

110793 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

Product Details

  • Weight
    2.34351106 lb
  • Series
    Spare parts
  • Product Class
    Accessories
  • Mission time
    20 y
  • B10D
    0,13 x 10⁶
  • PFHD
    3.7 x 10⁻⁹
  • Performance Level
    PL e
  • Switching element
    2 pos. driven NC
  • Product version number
    V4.0.0
  • Version
    Emergency stop
  • Category
    4
  • Power supply LED
    24 V DC
  • Assignment diagram
    L1
  • Output voltage
    UA-2V ... UA V DC (Value at a switching current of 50mA without taking into account the cable lengths)
  • Switching current
    1 ... 10 mA
  • Type of output
    Semiconductor outputs, p-switching, short circuit-proof
  • Switching voltage
    UA V
  • Test-pulse interval
    min.100 ms
  • Test pulses
    max.1 ms
  • Breaking capacity
    max.0,25 W
  • Output current
    max.50 mA
  • Operating voltage DC
    24 V DC -15% ... 10% ((Reverse polarity protected, regulated, residual ripple <5%, PELV))
  • Discrepancy time
    max.10 ms
  • Risk time according to EN 60947-5-3
    max.350 ms
  • Transponder coding
    Unicode
  • Safety class
    III
  • Current consumption
    max.80 mA ((no load on outputs))
  • Degree of contamination (external, according to EN 60947-1)
    3
  • Rated impulse withstand voltage Uimp
    1,5 kV
  • Utilization category acc. to EN 60947-5-2
    24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
  • Switching frequency
    0,25 Hz
  • Rated insulation voltage Ui
    30 V
  • Locking force FZh
    2000 N
  • Installation orientation
    Door hinge DIN left
  • Guard locking principle
    Closed-circuit current principle
  • Connection
    Plug connector RC18 (X6)
  • Mechanical life
    0,1 x 10⁶
  • Degree of protection
    IP65
  • Weight
    0,75 kg
  • Ambient temperature
    -20 ... 55 °C
  • Housing material
    Reinforced plastic; die-cast zinc nickel-plated, stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of 110793 on MQ Automation is $1,484.72. Order now.


About the product

Guard locking and guard lock monitoring;Can be connected in series with other AR devices (e.g. CES-AR and CET-AR);Emergency stop according to ISO 13850;2 pushbuttons (illuminated, ye, wh);incl. adhesive labels;With plug connector RC18;Unicode


Manufacturer warranty

110793 Euchner

$1,484.72

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$1,484.72

$1,484.72 each

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Manufacturer warranty


Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 110793 with other products

Weight

Series

Product Class

Mission time

B10D

PFHD

Performance Level

Switching element

Product version number

Version

Category

Power supply LED

Assignment diagram

Output voltage

Switching current

Type of output

Switching voltage

Test-pulse interval

Test pulses

Breaking capacity

Output current

Operating voltage DC

Discrepancy time

Risk time according to EN...

Transponder coding

Safety class

Current consumption

Degree of contamination (...

Rated impulse withstand v...

Utilization category acc....

Switching frequency

Rated insulation voltage ...

Locking force FZh

Installation orientation

Guard locking principle

Connection

Mechanical life

Degree of protection

Ambient temperature

Housing material

For the approval acc. to ...

Operating current

Repeat accuracy R

Detent mechanism

Off-state current Ir

Operating voltage

Turn-on time

Switching load

EMC protection requiremen...

Connection rating

Fusing

Overtravel

Extraction force

Actuating force

Shock and vibration resis...

Approach speed

Ready delay

Additional feature

Solenoid duty cycle

Solenoid operating voltag...

Extension of risk time ac...

Locking force Fmax

Retention force

Selected product

110793
0 in stock
110793
Euchner

110793 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, em...

Weight2.34351106 lb

SeriesSpare parts

Product ClassAccessories

Mission time20 y

B10D0,13 x 10⁶

PFHD3.7 x 10⁻⁹

Performance LevelPL e

Switching element2 pos. driven NC

Product version numberV4.0.0

VersionEmergency stop

Category4

Power supply LED24 V DC

Assignment diagramL1

Output voltageUA-2V ... UA V DC (Value at...

Switching current1 ... 10 mA

Type of outputSemiconductor outputs, p-swi...

Switching voltageU<sub>A</sub> V

Test-pulse intervalmin.100 ms

Test pulsesmax.1 ms

Breaking capacitymax.0,25 W

Output currentmax.50 mA

Operating voltage DC24 V DC -15% ... 10% ((Re...

Discrepancy timemax.10 ms

Risk time according to EN 60947-5-3max.350 ms

Transponder codingUnicode

Safety classIII

Current consumptionmax.80 mA ((no load on outp...

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp1,5 kV

Utilization category acc. to EN 60947-5-224V 200mA (Caution: outputs...

Switching frequency0,25 Hz

Rated insulation voltage Ui30 V

Locking force FZh2000 N

Installation orientationDoor hinge DIN left

Guard locking principleClosed-circuit current princ...

ConnectionPlug connector RC18 (X6)

Mechanical life0,1 x 10⁶

Degree of protectionIP65

Ambient temperature-20 ... 55 °C

Housing materialReinforced plastic; die-cast...

For the approval acc. to UL the following applies-

Operating current-

Repeat accuracy R-

Detent mechanism-

Off-state current Ir-

Operating voltage-

Turn-on time-

Switching load-

EMC protection requirements-

Connection rating-

Fusing-

Overtravel-

Extraction force-

Actuating force-

Shock and vibration resistance-

Approach speed-

Ready delay-

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

162926
1 in stock
162926
Euchner

162926 Euchner - MGBS-P-I-AP, emergency stop, 2 x M12

Weight3.968316 lb

SeriesMGBS-P-I-AP

Product ClassSafety System

Mission time20 y

B10D0,13 x 10⁶

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Switching element2 pos. driven NC

Product version number-

VersionEmergency stop

Category4

Power supply LED-

Assignment diagram-

Output voltage0 ... 1 V DC

Switching current1 ... 150 mA

Type of output2 semiconductor outputs, p-s...

Switching voltage-

Test-pulse intervalmin.100 ms

Test pulsesmax.0,3 ms (Applies for a l...

Breaking capacity-

Output current-

Operating voltage DC24 V DC -15% ... 15% Rev...

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3-

Transponder coding-

Safety classIII

Current consumption40 mA

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Switching frequencymax.0,5 Hz

Rated insulation voltage Ui50 V

Locking force FZh-

Installation orientationDoor hinge DIN right

Guard locking principle-

Connection2 plug connectors M12, 5-pin

Mechanical life1 x 10⁶

Degree of protectionIP65 (Screwed tight plug co...

Ambient temperature-20 ... +55 °C

Housing materialFiber glass reinforced therm...

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current1 ... 100 mA

Repeat accuracy R10 %

Detent mechanismSnap-in bolt

Off-state current Irmax.0,25 mA

Operating voltage5 ... 24 V

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating1 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delaymax.1 s

Additional feature-

Solenoid duty cycle-

Solenoid operating voltage DC-

Extension of risk time according to EN 60947-5-3 per device-

Locking force Fmax-

Retention force-

122813
12 in stock
122813
Euchner

122813 Euchner - Transponder-coded safety switch CTP-AR, 2 x M12, with escape release

Weight1.763696 lb

SeriesCTP-AR

Product ClassSafety System

Mission time20 y

B10D-

PFHD4.1 x 10 ⁻⁹

Performance LevelPL e

Switching element-

Product version number-

Version-

Category4

Power supply LED-

Assignment diagram-

Output voltage0,8xUB ... UB V DC

Switching current1 ... 50 mA

Type of outputp-switching, short circuit-p...

Switching voltage-

Test-pulse intervalmin.140 ms

Test pulsesmax.1,0 ms (Applies for a l...

Breaking capacity-

Output current-

Operating voltage DC24 V DC -15% ... 15% Rev...

Discrepancy timemax.10 ms In acc. with EN ...

Risk time according to EN 60947-5-3max.260 ms

Transponder coding-

Safety classIII

Current consumption40 mA

Degree of contamination (external, according to EN 60947-1)3

Rated impulse withstand voltage Uimp0,5 kV

Utilization category acc. to EN 60947-5-224V 150mA (Caution: outputs...

Switching frequencymax.0,5 Hz

Rated insulation voltage Ui50 V

Locking force FZh3000 N (Fzh = Fmax/1.3 Dep...

Installation orientationAny

Guard locking principleClosed-circuit current princ...

Connection2 plug connectors M12, 5 and...

Mechanical life1 x 10⁶

Degree of protectionIP67/IP69/IP69K (Screwed ti...

Ambient temperature-20 ... +55 °C

Housing materialDie-cast zinc

For the approval acc. to UL the following appliesOperation only with UL class...

Operating current-

Repeat accuracy R10 %

Detent mechanism-

Off-state current Irmax.0,25 mA

Operating voltage-

Turn-on timemax.400 ms

Switching load24V DC, class 2 (Alternativ...

EMC protection requirementsIn acc. with EN IEC 60947-5-...

Connection rating6 W

Fusing0,25 ... 8 A

Overtravel5 mm

Extraction force20 N

Actuating force10 N

Shock and vibration resistanceIn acc. with EN 60947-5-3

Approach speedmax.20 m/min

Ready delay8 s

Additional featureEscape release actuated by p...

Solenoid duty cycle100 %

Solenoid operating voltage DC24 V DC -15% ... +10% Re...

Extension of risk time according to EN 60947-5-3 per devicemax.5 ms

Locking force Fmax3900 N

Retention force20 N

About the manufacturer

Euchner

As experts in industrial safety engineering, we design and produce customized products and solutions to meet the needs of clients across various industries. Implementing our safety guards on machinery and installations reduces hazards and risks, thereby safeguarding both individuals and processes. With a global team of 800 employees, safety remains our top priority.

Recently viewed products

Relevant products

FAQ

What is the price of 110793?
The price of 110793 on MQ Automation is $1,484.72. Order now.

Out if stock but available for backorder.

110793 Euchner - Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18

What can I help you find today?

Recommended parts